An Enhanced Adaptive Algorithm to Mitigate Mis-coordination Problem of the Third Zone of Distance Relays

Journal of Applied Research and Technology - Tập 13 - Trang 87-96 - 2015
M. Azari1, M. Ojaghi1, K. Mazlumi1
1Electrical Engineering Department, University of Zanjan, Zanjan, Iran

Tài liệu tham khảo

Jonsson, 2003, An adaptive scheme to prevent undesirable distance protection operation during voltage instability, IEEE Transactions on Power Delivery, 18, 1174, 10.1109/TPWRD.2003.817501 Nuqui, 2003, Fast on-line voltage security monitoring using synchronized phasor measurements and decision trees, Proc. IEEE Power Eng. Soc. WinterMeeting, 3, 1347 Begovic, 1989, Power system emergency control near voltage instability, Proc. IEEE 28th Decision and Control, 13, 2179, 10.1109/CDC.1989.70553 He, 2006, An adaptive distance relay based on transient error estimation of CVT, IEEE Transactions on Power Delivery, 21, 1856, 10.1109/TPWRD.2006.877098 Samantaray, 2008, Transmission line distance relaying using a variable window short-time Fourier transform, Electric Power Systems Research, 78, 595, 10.1016/j.epsr.2007.05.005 Bhalja, 2007, High-resistance faults on two terminal parallel transmission line: Analysis, simulation studies, and an adaptive distance relaying scheme, IEEE Transactions on Power Delivery, 22, 801, 10.1109/TPWRD.2007.893352 Lu, 2009, An adaptive distance relaying algorithm with a morphological fault detector embedded, Proc. Power & Energy Society General Meeting, 1, 10.1109/PES.2009.5275579 Chen, 2006, Application of combined adaptive fourier Altering technique and fault detector to fast distance protection, IEEE Transactions on Power Delivery, 21, 619, 10.1109/TPWRD.2005.858808 Sidhu, 2004, A new method for determining settings of zone-2 distance relays, Electric Power Component System, 32, 275, 10.1080/15325000490208056 Sorrentino, 2011, Optimal- probabilistic method to compute the reach settings of distance relays, IEEE Transactions on Power Delivery, 26, 1522, 10.1109/TPWRD.2010.2091724 Nayak, 2014, Secured zone 3 protection during stressed condition, IEEE Transactions on Power Delivery, 1 Li, 2007, Operation margin analysis of zone 3 impedance relay based on sensitivities to power injection, Generation, Transmission & Distribution, IET, 1, 312, 10.1049/iet-gtd:20060083 Horowitz, 2006, Third Zone Revisited, IEEE Transactions on Power Delivery, 21, 23, 10.1109/TPWRD.2005.860244 Franklin, 2011, Determining distance relay Zone-1 reach settings to prevent CCVT transient overreach, 1 Bin Abidin, 2011, Adaptive settings of distance protection to prevent mal-operation under severe voltage fluctuation, 162 Biswal, 2013, Adaptive distance relay setting for series compensated line, Electrical Power & Energy Systems, 52, 198, 10.1016/j.ijepes.2013.03.018 Arvind, 2013, Adaptive distance protection of transmission line in presence of SVC, Electrical Power & Energy Systems, 53, 78, 10.1016/j.ijepes.2013.03.020 Shuntao, 2010, A new algorithm for relay setting and coordination in power system, 349 El-Hadidy, 2010, A new algorithm to improve the operation of distance relays zone 3 by using Synchronized Phasor Measurements, Proc. International Symposium of Modern Electric Power Systems (MEPS), 1 Kundu, 2014, Synchrophasor-assisted zone 3 operation, IEEE Transactions on Power Delivery, 29, 660, 10.1109/TPWRD.2013.2276071 Naidu, 2013, Synchrophasor- assisted zone 3 operation, Proc. IEEE ISGT Asia, 1 Ortiz, 2012, Implementation and real time test of an accelerated zone 2 trip scheme for non-communicated distance relays, IEEE Latin America Transactions, 10, 1916, 10.1109/TLA.2012.6272474 Power system test cases. 1999. [Online]. Available: http://www.ee.washington.edu/research/pstca/pf30/ieee30cdf.txt.