Advantages and Drawbacks of Popular Supercritical Fluid Chromatography / Mass Spectrometry Interfacing Approaches—A User's Perspective

European Journal of Mass Spectrometry - Tập 11 Số 2 - Trang 189-197 - 2005
J. David Pinkston1
1Procter & Gamble Pharmaceuticals, Health Care Research Center, 8700 Mason-Montgomery Rd, PO Box 8006, Mason, OH 45040, USA

Tóm tắt

Mobile phases in supercritical fluid chromatography (SFC) have low viscosities and high diffusion coefficients with respect to those of traditional high-performance liquid chromatography (HPLC). These properties allow higher mobile phase flow rates and/or longer columns in SFC, resulting in rapid analyses and high efficiency separations. In addition, chiral SFC is becoming especially popular. Mass spectrometry (MS) is arguably the most popular “informative” detector for chromatographic separations. Most SFC/MS is performed with atmospheric pressure ionization (API) sources. Unlike LC/MS, the interface between the SFC column and the API source must allow control of the downstream (post-column) pressure while also providing good chromatographic fidelity. Here, we compare and contrast the popular interfacing approaches. Some are simple, such as direct effluent introduction with no active back pressure regulator (BPR) in high-speed bioanalytical applications. The pressure-regulating fluid interface is more versatile and provides excellent chromatographic fidelity, but is less user friendly. The pre-BPR-split interface and an interface which provides total flow introduction with a mechanical BPR are good compromises between user friendliness and performance and have become the most popular among practitioners. Applications of SFC/MS using these various interfaces are also discussed.

Từ khóa


Tài liệu tham khảo

1988, 1988 Workshop on Supercritical Fluid Chromatography

10.1021/ac040088p

10.1021/bk-1988-0366.ch011

10.1021/ac00248a055

10.1002/bms.1200150409

10.1016/S0021-9673(01)96500-8

10.1016/S0021-9673(01)88462-4

10.1021/ac00278a079

10.1021/ac00169a035

Pinkston J.D., 1994, “Electron Ionization in SFC/MS: A Systematic Evaluation of the Relative Significance of True Electron Ionization and of Mobile-Phase Mediated Charge-Exchange Ionization”

10.1016/1044-0305(92)87048-4

Henion J.D., 1988, “SFC/MS Analysis of Biological Samples with Electron Ionization”

10.1007/BF00323741

10.1002/rcm.1290020103

Games D.E., 1987, Anal. Proc. (London), 24, 371

10.1002/bms.1200190604

10.1016/S0021-9673(01)93906-8

10.1016/S0021-9673(01)88813-0

10.1021/ac00081a005

10.1093/chromsci/27.6.274

10.1016/0021-9673(94)80164-9

10.1016/0021-9673(95)00238-I

10.1016/S0021-9673(01)93289-3

10.1016/0021-9673(93)83415-O

10.1016/0021-9673(95)01199-4

10.1016/S0021-9673(97)00984-9

10.1016/S0165-022X(00)00055-5

10.1021/ac981372h

10.1002/rcm.1290091202

10.1016/S0021-9673(97)00665-1

10.1002/mas.10060

10.1016/S0021-9673(03)00725-8

10.1021/cc020093b

10.1007/BF02492499

10.1016/S0021-9673(98)00082-X

10.1016/S1044-0305(98)00006-3

10.1016/S1044-0305(02)00436-1

10.1021/ac0014820