Advanced microscopy techniques to assess solid-state properties of inhalation medicines
Tài liệu tham khảo
Smyth, 2005, Propellant-driven metered-dose inhalers for pulmonary drug delivery, Expert Opin. Drug Deliv., 2, 53, 10.1517/17425247.2.1.53
Newman, 2005, Principles of metered-dose inhaler design, Respir. Care, 50, 1177
McDonald, 2000, Transition to CFC-free metered dose inhalers — into the new millennium, Int. J. Pharm., 201, 89, 10.1016/S0378-5173(00)00401-4
Telko, 2005, Dry powder inhaler formulation, Respir. Care, 50, 1209
Edge, 2008, Factors affecting defining the quality and functionality of excipients used in the manufacture of dry powder inhaler products, Drug Dev. Ind. Pharm., 34, 966, 10.1080/03639040802192814
Chan, 2006, Dry powder aerosol drug delivery — opportunities for colloid and surface scientists, Colloid Surf. A., 284, 50, 10.1016/j.colsurfa.2005.10.091
Srichana, 1998, On the relationship between drug and carrier deposition from dry powder inhalers in vitro, Int. J. Pharm., 167, 13, 10.1016/S0378-5173(98)00037-4
Rogueda, 2005, Novel hydrofluoroalkane suspension formulations for respiratory drug delivery, Expert Opin. Drug Deliv., 2, 625, 10.1517/17425247.2.4.625
Newman, 2002, Evolution of dry powder inhaler design, formulation, and performance, Respir. Med., 96, 293, 10.1053/rmed.2001.1276
Hickey, 2007, Physical characterization of component particles included in dry powder inhalers. I. Strategy review and static characteristics, J. Pharm. Sci., 96, 1282, 10.1002/jps.20916
Lehto, 2004, Moisture transfer into medicament chambers equipped with a double-barrier-desiccant system, Int. J. Pharm., 275, 155, 10.1016/j.ijpharm.2004.01.026
Ng, 2008, Anomalous particle size shift during post-milling storage, Pharm. Res., 25, 1175, 10.1007/s11095-007-9497-8
United States Pharmacopoeia, (31st Rev. ed.), Aerosol <601> (2008). Rockville, MD: The United States Pharmacopoeial Convention, Inc, Retrieved September 8, 2008, from www.uspnf.com.
Food and Drug Administration, 1998, Guidance for industry metered dose inhaler (MDI) and dry powder inhaler (DPI) drug products
Cooke, 2000, Chemical microscopy, Anal. Chem., 72, 169R, 10.1021/a1000012s
Surman, 1996, Comparison of microscope techniques for the examination of biofilms, J. Microbiol. Meth., 25, 57, 10.1016/0167-7012(95)00085-2
Ruozi, 2011, AFM, ESEM, TEM, and CLSM in liposomal characterization: a comparative study, Int. J. Nanomed., 6, 557, 10.2147/IJN.S14615
Young, 2003, Effect of humidity on aerosolization of micronized drugs, Drug Dev. Ind. Pharm., 29, 959, 10.1081/DDC-120025453
Islam, 2004, Lactose surface modification by decantation: are drug-fine lactose ratios the key to better dispersion of salmeterol xinafoate from lactose-interactive mixtures?, Pharm. Res., 21, 492, 10.1023/B:PHAM.0000019304.91412.18
Bunker, 2005, Towards screening of inhalation formulations: measuring interactions with atomic force microscopy, Expert Opin. Drug Deliv., 2, 613, 10.1517/17425247.2.4.613
Davies, 2005, Characterization of drug particle surface energetics and Young's modulus by atomic force microscopy and inverse gas chromatography, Pharm. Res., 22, 1158, 10.1007/s11095-005-5647-z
Traini, 2005, Surface energy and interparticle force correlation in model pMDI formulations, Pharm. Res., 22, 816, 10.1007/s11095-005-2599-2
Liao, 2004, Characterization of pharmaceutical solids by scanning probe microscopy, J. Pharm. Sci., 93, 2250, 10.1002/jps.20139
Shotton, 1995, Electronic light-microscopy — present capabilities and future-prospects, Histochem. Cell Biol., 104, 97, 10.1007/BF01451571
Elkady, 2007, Scanning transmitted and reflected light microscopy: a novel microscopy for visualizing biomaterials at interfaces, Micron, 38, 848, 10.1016/j.micron.2007.06.004
Mitchell, 2007, In vitro and in vivo aspects of cascade impactor tests and inhaler performance: a review, AAPS Pharm. Sci. Tech., 8, E1, 10.1208/pt0804110
United States Pharmacopoeia, (31st Rev. ed.), Particulate matter in injections <788> (2008). Rockville, MD: The United States Pharmacopoeial Convention, Inc, Retrieved September 8, 2008, from www.uspnf.com.
O'Shaughnessy, 1997, Evaluating particle counters, J. Am. Water Works Ass., 89, 60, 10.1002/j.1551-8833.1997.tb08340.x
Niemann, 2006, A Critical Comparison: Particle Counting with Light Obscuration and Automated Raman Microscopy, 529
Larhrib, 2003, The influence of carrier and drug morphology on drug delivery from dry powder formulations, Int. J. Pharm., 257, 283, 10.1016/S0378-5173(03)00156-X
Kaialy, 2011, Characterisation and deposition studies of recrystallised lactose from binary mixtures of ethanol/butanol for improved drug delivery from dry powder inhalers, AAPS J., 13, 30, 10.1208/s12248-010-9241-x
Kaialy, 2010, Engineered mannitol as an alternative carrier to enhance deep lung penetration of salbutamol sulphate from dry powder inhaler, Colloids Surf. B., 79, 345, 10.1016/j.colsurfb.2010.04.016
Oldenbourg, 2008, Polarized light field microscopy: an analytical method using a microlens array to simultaneously capture both conoscopic and orthoscopic views of birefringent objects, J. Microsc., 231, 419, 10.1111/j.1365-2818.2008.02053.x
Knowles, 2004, Microscopy and microanalysis of crystalline glazes, J. Microsc., 215, 257, 10.1111/j.0022-2720.2004.01380.x
Omura, 2010, Problems in polarized light microscopy observation of birefringence of calcium pyrophosphate dihydrate crystals, Micron, 41, 974, 10.1016/j.micron.2010.07.001
Price, 2003, Visualization of the crystallization of lactose from the amorphous state, J. Pharm. Sci., 93, 155, 10.1002/jps.10513
Shur, 2008, Cospray-dried unfractionated heparin with L-leucine as a dry powder inhaler mucolytic for cystic fibrosis therapy, J. Pharm. Sci., 97, 4857, 10.1002/jps.21362
Boyer, 2010, Crystallization of polymers at constant and high cooling rates: a new hot-stage microscopy set-up, Polym. Test., 29, 445, 10.1016/j.polymertesting.2010.02.003
Vitez, 1998, The evolution of hot-stage microscopy to aid solid-state characterizations of pharmaceutical solids, Thermochim. Acta., 327, 187, 10.1016/S0040-6031(98)00535-8
Chan, 1998, Solid state characterization of spray-dried powders of recombinant human deoxyribonuclease (RhDNase), J. Pharm. Sci., 87, 647, 10.1021/js9504292
Littringer, 2011
Sun, 1995, Using laser-scanning confocal microscopy as a guide for electron-microscopic study — a simple method for correlation of light and electron-microscopy, J. Histochem. Cytochem., 43, 329, 10.1177/43.3.7868862
Maggiano, 2009, Confocal laser scanning microscopy: a flexible tool for simultaneous polarization and three-dimensional fluorescence imaging of archaeological compact bone, J. Archaeol. Sci., 36, 2392, 10.1016/j.jas.2009.06.021
Chew, 2001, Use of solid corrugated particles to enhance powder aerosol performance, Pharm. Res., 18, 1570, 10.1023/A:1013082531394
Maas, 2011, The impact of spray drying outlet temperature on the particle morphology of mannitol, Powder Technology., 213, 27, 10.1016/j.powtec.2011.06.024
Casuccio, 2004, Measurement of fine particulate matter using electron microscopy techniques, Fuel Process Technol., 85, 763, 10.1016/j.fuproc.2003.11.026
Srinivasan, 2007, Scanning electron microscopy of nanoscale chemical patterns, ACS Nano, 1, 191, 10.1021/nn7000799
Berard, 2002, Dry powder inhaler: influence of humidity on topology and adhesion studied by AFM, Int. J. Pharm., 232, 213, 10.1016/S0378-5173(01)00913-9
Murtomaa, 2004, Effect of particle morphology on the triboelectrification in dry powder inhalers, Int. J. Pharm., 282, 107, 10.1016/j.ijpharm.2004.06.002
Shur, 2008, The spray drying of unfractionated heparin: optimization of the operating parameters, Drug Dev. Ind. Pharm., 34, 559, 10.1080/03639040701657552
Maa, 1999, Protein inhalation powders: spray drying vs spray freeze drying, Pharm. Res., 16, 249, 10.1023/A:1018828425184
Shekunov, 2003, Aerosolisation behaviour of micronised and supercritically-processed powders, J. Aerosol Sci., 34, 553, 10.1016/S0021-8502(03)00022-3
Kaerger, 2004, Processing of spherical crystalline particles via a novel solution atomization and crystallization by sonication (SAXS) technique, Pharm. Res., 21, 372, 10.1023/B:PHAM.0000016252.97296.f1
Murnane, 2008, In situ and Ex situ analysis of salmeterol xinafoate microcrystal formation from poly(ethylene glycol) 400 — water cosolvent mixtures, Cryst. Growth. Des., 8, 1855, 10.1021/cg700953k
Adi, 2008, The influence of drug morphology on aerosolisation efficiency of dry powder inhaler formulations, J. Pharm. Sci., 97, 2780, 10.1002/jps.21195
Pitchayajittipong, 2010, Characterisation and functionality of inhalation anhydrous lactose, Int. J. Pharm., 390, 134, 10.1016/j.ijpharm.2010.01.028
Kawashima, 1998, Effect of surface morphology of carrier lactose on dry powder inhalation property of pranlukast hydrate, Int. J. Pharm., 172, 179, 10.1016/S0378-5173(98)00202-6
Zeng, 2001, Lactose as a carrier in dry powder formulations: the influence of surface characteristics on drug delivery, J. Pharm. Sci., 90, 1424, 10.1002/jps.1094
Heng, 2000, Quantification of the surface morphologies of lactose carriers and their effect on the in vitro deposition of salbutamol sulphate, Chem. Pharm. Bull., 48, 393, 10.1248/cpb.48.393
Xu, 2010, Dry powder aerosols generated by standardized entrainment tubes from drug blends with lactose monohydrate: 2. Ipratropium bromide monohydrate and fluticasone propionate, J. Pharm. Sci., 99, 3415, 10.1002/jps.22100
Young, 2008, Lactose composite carriers for respiratory delivery, Pharm. Res., 26, 802, 10.1007/s11095-008-9779-9
Donovan, 2010, Influence of size and surface roughness of large lactose carrier particles in dry powder inhaler formulations, Int. J. Pharm., 402, 1, 10.1016/j.ijpharm.2010.08.045
Ferrari, 2004, The surface roughness of lactose particles can be modulated by wet-smoothing using a high-shear mixer, AAPS Pharm. Sci. Tech., 5, 1, 10.1208/pt050460
Young, 2007, The influence of mechanical processing of dry powder inhaler carriers on drug aerosolization performance, J. Pharm. Sci., 96, 1331, 10.1002/jps.20933
Shur, 2008, The role of fines in the modification of the fluidization and dispersion mechanism within dry powder inhaler formulations, Pharm. Res., 25, 1631, 10.1007/s11095-008-9538-y
Jones, 2008, An investigation into the relationship between carrier-based dry powder inhalation performance and formulation cohesive–adhesive force balances, Eur. J. Pharm. Biopharm., 69, 496, 10.1016/j.ejpb.2007.11.019
Jones, 2006, The influence of fine excipient particles on the performance of carrier-based dry powder inhalation formulations, Pharm. Res., 23, 1665, 10.1007/s11095-006-9012-7
Adi, 2006, Agglomerate strength and dispersion of salmeterol xinafoate from powder mixtures for inhalation, Pharm. Res., 23, 2556, 10.1007/s11095-006-9082-6
Kirk, 2009, Application of environmental scanning electron microscopy to determine biological surface structure, J. Microsc., 233, 205, 10.1111/j.1365-2818.2009.03111.x
Wight, 1993, Environmental scanning electron-microscope imaging examples related to particle analysis, Microsc. Res. Techniq., 25, 393, 10.1002/jemt.1070250507
Watling, 2010, Surface modification of lactose inhalation blends by moisture, Int. J. Pharm., 391, 29, 10.1016/j.ijpharm.2010.02.011
Huyang, 2009, Focused ion beam processing and engineering of devices in self-assembled supramolecular structures, Nanotechnology, 20, 1, 10.1088/0957-4484/20/48/485301
Friedmann, 2011, Investigation of cell-substrate interactions by focused ion beam preparation and scanning electron microscopy, Acta Biomater., 7, 2499, 10.1016/j.actbio.2011.02.024
Wallace, 2011, Subsurface examination of a foliar biofilm using scanning electron- and focused-ion-beam microscopy, Micron, 42, 579, 10.1016/j.micron.2011.02.003
Heng, 2007, Focused-ion-beam milling: a novel approach to probing the interior of particles used for inhalation aerosols, Pharm. Res., 24, 1608, 10.1007/s11095-007-9276-6
Chew, 1999, Influence of particle size, air flow, and inhaler device on the dispersion of mannitol powders as aerosols, Pharm. Res., 16, 1098, 10.1023/A:1018952203687
Hansma, 1998, Atomic force microscopy and other scanning probe microscopies, Curr. Opin. Chem. Biol., 2, 579, 10.1016/S1367-5931(98)80086-0
Binnig, 1986, Atomic force microscope, Phys. Rev. Lett., 56, 930, 10.1103/PhysRevLett.56.930
Hansma, 2000, Probing biopolymers with the atomic force microscope: a review, J. Biomater. Sci. Polym. Ed., 11, 675, 10.1163/156856200743940
Giessibl, 2003, Advances in atomic force microscopy, Rev. Mod. Phys., 75, 949, 10.1103/RevModPhys.75.949
Louey, 2001, Characterisation of adhesional properties of lactose carriers using atomic force microscopy, J. Pharm. Biomed. Anal., 25, 559, 10.1016/S0731-7085(00)00523-9
Price, 2002, The influence of relative humidity on particulate interactions in carrier-based dry powder inhaler formulations, Int. J. Pharm., 246, 47, 10.1016/S0378-5173(02)00359-9
Roberts, 2005, What can we learn from atomic force microscopy adhesion measurements with single drug particles?, Eur. J. Pharm. Sci., 24, 153, 10.1016/j.ejps.2004.11.002
Islam, 2005, Surface roughness contribution to the adhesion force distribution of salmeterol xinafoate on lactose carriers by atomic force microscopy, J. Pharm. Sci., 94, 1500, 10.1002/jps.20381
Strathmann, 2009, Forces between insulin microspheres and polymers surfaces for a dry powder inhaler, Int. J. Pharm., 372, 147, 10.1016/j.ijpharm.2009.01.004
Young, 2004, The influence of humidity on the aerosolisation of micronised and SEDS produced salbutamol sulphate, Eur. J. Pharm. Sci., 22, 235, 10.1016/j.ejps.2004.03.006
Louey, 2002, Particle interactions involved in aerosol dispersion of ternary interactive mixtures, Pharm. Res., 19, 1524, 10.1023/A:1020464801786
Young, 2003, Under pressure: predicting pressurized metered dose inhaler interactions using the atomic force microscope, J. Colloid. Interf. Sci., 262, 298, 10.1016/S0021-9797(03)00032-8
Traini, 2005, Surface energy and interparticle force correlation in model pMDI formulations, Pharm. Res., 22, 816, 10.1007/s11095-005-2599-2
Traini, 2006, In Vitro investigation of drug particulates interactions and aerosol performance of pressurised metered dose Inhalers, Pharm. Res., 24, 125, 10.1007/s11095-006-9130-2
Young, 2009, The influence of micronised particulates on the aerosolisation properties of pressurised metered dose inhalers, J. Aerosol Sci., 40, 324, 10.1016/j.jaerosci.2008.12.006
Rogueda, 2011, Particle synergy and aerosol performance in non-aqueous liquid of two combinations metered dose inhalation formulations: an AFM and Raman investigation, J. Colloid. Interf. Sci., 361, 649, 10.1016/j.jcis.2011.05.073
Esayanur, 2005, Interaction force measurements using atomic force microscopy for characterization and control of adhesion, dispersion and lubrication in particulate systems, J. Adhes. Sci. Technol., 19, 611, 10.1163/1568561054890516
Turner, 2007, Scanning probe microscopy in the field of drug delivery, Adv. Drug Deliv. Rev., 59, 1453, 10.1016/j.addr.2007.08.020
Hooton, 2003, Characterization of particle-interactions by atomic force microscopy: effect of contact area, Pharm. Res., 20, 508, 10.1023/A:1022684911383
Hooton, 2004, An atomic force microscopy study of the effect of nanoscale contact geometry and surface chemistry on the adhesion of pharmaceutical particles, Pharm. Res., 21, 953, 10.1023/B:PHAM.0000029283.47643.9c
Begat, 2004, The cohesive–adhesive balances in dry powder inhaler formulations I: direct quantification by atomic force microscopy, Pharm. Res., 21, 1591, 10.1023/B:PHAM.0000041453.24419.8a
Begat, 2004, The cohesive–adhesive balances in dry powder inhaler formulations II: influence on fine particle delivery characteristics, Pharm. Res., 21, 1826, 10.1023/B:PHAM.0000045236.60029.cb
Hooton, 2006, Predicting the behavior of novel sugar carriers for dry powder inhaler formulations via the use of a cohesive–adhesive force balance approach, J. Pharm. Sci., 95, 1288, 10.1002/jps.20618
Hooton, 2008, The influence of crystal habit on the prediction of dry powder inhalation formulation performance using the cohesive–adhesive force balance approach, Drug Dev. Ind. Pharm., 34, 974, 10.1080/03639040802149087
Jones, 2007, An Investigation into the dispersion mechanisms of ternary dry powder inhaler formulations by the quantification of interparticulate forces, Pharm. Res., 25, 337, 10.1007/s11095-007-9467-1
Shur, 2007, Effect of surface amorphous content of active pharmaceutical ingredients on the performance of dry powder inhaler formulations, 341
Morita, 1996, Contact and non-contact mode imaging by atomic force microscopy, Thin Solid Films, 273, 138, 10.1016/0040-6090(95)06806-6
Begat, 2003, The effect of mechanical processing on surface stability of pharmaceutical powders: visualization by atomic force microscopy, J. Pharm. Sci., 92, 611, 10.1002/jps.10320
Traini, 2006, Comparative study of erythritol and lactose monohydrate as carriers for inhalation: atomic force microscopy and in vitro correlation, Eur. J. Pharm. Sci., 27, 243, 10.1016/j.ejps.2005.10.005
Jones, 2006, Dehydration of trehalose dihydrate at low relative humidity and ambient temperature, Int. J. Pharm., 313, 87, 10.1016/j.ijpharm.2006.01.026
Young, 2002, Characterization of a surface modified dry powder inhalation carrier prepared by “particle smoothing”, J. Pharm. Pharmacol., 54, 1339, 10.1211/002235702760345400
Danesh, 2000, Polymorphic discrimination using atomic force microscopy: distinguishing between two polymorphs of the drug cimetidine, Langmuir, 16, 866, 10.1021/la990470a
Baker, 2001, Internal structure of the starch granule revealed by AFM, Carbohydr. Res., 330, 249, 10.1016/S0008-6215(00)00275-5
Price, 2005, On the physical transformations of processed pharmaceutical solids, Micron, 36, 519, 10.1016/j.micron.2005.04.003
Bowe, 1998, White light interferometric surface profiler, Opt. Eng., 37, 1796, 10.1117/1.601727
Adi, 2008, Scanning white-light interferometry as a novel technique to quantify the surface roughness of micron-sized particles for inhalation, Langmuir, 24, 11307, 10.1021/la8016062
Harding, 2007, Two- and three-dimensional imaging of multicomponent systems using scanning thermal microscopy and localized thermomechanical analysis, Anal. Chem., 79, 129, 10.1021/ac061190k
Harding, 2007, Nanoscale characterisation and imaging of partially amorphous materials using local thermomechanical analysis and heated tip AFM, Pharm. Res., 24, 2048, 10.1007/s11095-007-9339-8
Schmidt, 2006, Raman spectral imaging — a nondestructive, high resolution analysis technique for local stress measurements in silicon, Vib. Spectrosc., 42, 93, 10.1016/j.vibspec.2006.01.005
Mansour, 2007, Raman characterization and chemical imaging of biocolloidal self-assemblies, drug delivery systems, and pulmonary inhalation aerosols: a review, AAPS Pharm. Sci. Tech., 8, E1, 10.1208/pt0804099
Corrigan, 2006, Physicochemical and in vitro deposition properties of salbutamol sulphate/ipratropium bromide and salbutamol sulphate/excipient spray dried mixtures for use in dry powder inhalers, Int. J. Pharm., 322, 22, 10.1016/j.ijpharm.2006.05.022
Rabbani, 2011, TOF-SIMS with argon gas cluster ion beams: a comparison with C60+, Anal. Chem., 83, 3793, 10.1021/ac200288v
Ogaki, 2011, Surface mass spectrometry of two component drug-polymer systems: novel chromatographic separation method using gentle-secondary ion mass spectrometry (G-SIMS), Anal. Chem., 83, 3627, 10.1021/ac200347a
Almstrand, 2011, TOF-SIMS analysis of exhaled particles from patients with asthma and healthy controls, Eur. Respir. J., 39, 59, 10.1183/09031936.00195610
Bunker, 2006, Single particle friction on blister packaging materials used in dry powder inhalers, Eur. J. Pharm. Sci., 29, 405, 10.1016/j.ejps.2006.08.001
Zhou, 2011, Investigation of the extent of surface coating via mechanofusion with varying additive levels and the influences on bulk powder flow properties, Int. J. Pharm., 413, 36, 10.1016/j.ijpharm.2011.04.014
Kudelski, 2009, Raman spectroscopy of surfaces, Surf. Sci., 603, 1328, 10.1016/j.susc.2008.11.039
Schoenherr, 2009, Confocal Raman microscopy to probe content uniformity of a lipid based powder for inhalation: a quality by design approach, Eur. J. Pharm. Sci., 38, 47, 10.1016/j.ejps.2009.05.011
Connatser, 2010, Toward surface-enhanced Raman imaging of latent fingerprints, J. Forensic Sci., 55, 1462, 10.1111/j.1556-4029.2010.01484.x
Steele, 2004, The potential use of raman mapping to investigate in vitro deposition of combination pressurized metered-dose inhalers, AAPS Pharm. Sci. Tech., 6, 1
Theophilus, 2006, Co-deposition of salmeterol and fluticasone propionate by a combination inhaler, Int. J. Pharm., 313, 14, 10.1016/j.ijpharm.2006.01.018
Barnes, 2002, Scientific rationale for inhaled combination therapy with long-acting 2-agonists and corticosteroids, Eur. Respir. J., 19, 182, 10.1183/09031936.02.00283202
Šašić, 2010, Global illumination Raman chemical imaging of a combination of two drug molecules in a dry powder inhaler formulation, Anal. Methods., 2, 1528, 10.1039/c0ay00371a
Shur, 2011, Investigating the structure–function relationship of combination dry powder inhaler formulations, 479
Fu, 2006, Investigation of particle packing in model pharmaceutical powders using X-ray microtomography and discrete element method, Powder Tech., 167, 134, 10.1016/j.powtec.2006.06.011
Miguélez-Morán, 2009, Characterisation of density distributions in roller-compacted ribbons using micro-indentation and X-ray micro-computed tomography, Eur. J. Pharm. Biopharm., 72, 173, 10.1016/j.ejpb.2008.12.005
Williams, 2010, Computational X-ray tomography techniques as development tools for nasal and pulmonary device optimization, 895
Miller, 2005, Non-destructive density measurements of compacted lactose using X-ray microtomography, 18
Stuart, 2009, The role of X-ray computed tomography as an investigation tool in hardware design, 213
