Accuracy of full-arch scans using intraoral scanners

Sebastian B. M. Patzelt1,2, Archontia Emmanouilidi1, Susanne Stampf3, Jörg Rudolf Strub1, Wael Att1
1Department of Prosthodontics, School of Dentistry, University Medical Center Freiburg, Freiburg, Germany
2Department of Periodontics, School of Dentistry, University of Maryland Baltimore, Baltimore, USA
3Institute of Medical Biometry and Medical Informatics, Department of Medical Biometry and Statistics, University Medical Center Freiburg, Freiburg, Germany

Tóm tắt

Từ khóa


Tài liệu tham khảo

Quaas S, Rudolph H, Luthardt RG (2007) Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/CAM restorations. J Dent 35(12):903–908

Schoenbaum TR (2010) Decoding CAD/CAM and digital impression units. Dent Today 29(2):140, 142, 144–145

Clancy JM, Scandrett FR, Ettinger RL (1983) Long-term dimensional stability of three current elastomers. J Oral Rehabil 10(4):325–333

Endo T, Finger WJ (2006) Dimensional accuracy of a new polyether impression material. Quintessence Int 37(1):47–51

Jamani KD, Harrington E, Wilson HJ (1989) Rigidity of elastomeric impression materials. J Oral Rehabil 16(3):241–248

Shafa S, Zaree Z, Mosharraf R (2008) The effects of custom tray material on the accuracy of master casts. J Contemp Dent Pract 9(6):49–56

Shetty P, Rodrigues S (2006) Accuracy of elastomeric impression materials on repeated pours. J Indian Prosthodont Soc 6(2):61–71

Wostmann B, Rehmann P, Balkenhol M (2009) Accuracy of impressions obtained with dual-arch trays. Int J Prosthodont 22(2):158–160

Zweig A (2009) Improving impressions: go digital! Dent Today 28(11):100, 102, 104

Christensen GJ (2008) Will digital impressions eliminate the current problems with conventional impressions? J Am Dent Assoc 139(6):761–763

Christensen GJ (2009) Impressions are changing: deciding on conventional, digital or digital plus in-office milling. J Am Dent Assoc 140(10):1301–1304

Ender A, Mehl A (2011) Full arch scans: conventional versus digital impressions—an in-vitro study. Int J Comput Dent 14(1):11–21

Luthardt RG, Loos R, Quaas S (2005) Accuracy of intraoral data acquisition in comparison to the conventional impression. Int J Comput Dent 8(4):283–294

van der Meer WJ, Andriessen FS, Wismeijer D, Ren Y (2012) Application of intra-oral dental scanners in the digital workflow of implantology. PLoS One 7(8):e43312. doi: 10.1371/journal.pone.0043312

Ender A, Mehl A (2013) Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision. J Prosthet Dent 109(2):121–128. doi: 10.1016/S0022-3913(13)60028-1

Mehl A, Ender A, Mormann W, Attin T (2009) Accuracy testing of a new intraoral 3D camera. Int J Comput Dent 12(1):11–28

Guth JF, Keul C, Stimmelmayr M, Beuer F, Edelhoff D (2012) Accuracy of digital models obtained by direct and indirect data capturing. Clin Oral Investig. doi: 10.1007/s00784-012-0795-0

Seelbach P, Brueckel C, Wostmann B (2012) Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig. doi: 10.1007/s00784-012-0864-4

Babayoff N, Glaser-Inbari I (2000) Imaging a three-dimensional structure by confocal focussing an array of light beams. International Publication WO 00/08415

Birnbaum NS, Aaronson HB, Stevens C, Cohen B (2009) 3D digital scanners: a high-tech approach to more accurate dental impressions. Insid Dent 5:70–74

Wachman ES, Niu W, Farkas DL (1997) AOTF microscope for imaging with increased speed and spectral versatility. Biophys J 73(3):1215–1222

Brandestini M, Moermann WH (1989) Method of and apparatus for making a prosthesis, especially a dental prosthesis. US Patent 4663720

Schwotzer A (2007) Measuring device and method that operates according to the basic principles of confocal microscopy. US Patent 2007/0296959

Thiel F, Pfeiffer J, Fornoff P (2008) Apparatus and method for optical 3D measurement. International Publication WO 2008/092791

Schmidt V (2010) 3D dental camera for recording surface structures of a measuring object by means of triangulation. International Publication WO 2010/012838 A1

Seitz G, Tiziani HJ (1996) Resolution limits of active triangulation systems by defocusing. Opt Eng 32(6):1374–1383

Kovács T (2004) Active triangulation scanner development focusing on the accuracy of the detection. In: 5th International Symposium of Hungarian Researchers: Sponsored by IEEE Computational Intelligence Chapter, Budapest, Magyarország, 2004.11.11–2004.11.12. pp 183–194

Logozzo S, Franceschini G, Kilpelä A, Caponi M, Governi L, Blois L (2011) A comparative analysis of intraoral 3D digital scanners for restorative dentistry. Internet J Med Technol 5(1). http://ispub.com/IJMT/5/1/10082

Berner M (2010) Optical system for a confocal microscope. US Patent 2010/0085636

Figerio F (2006) 3-dimensional surface imaging using active wavefront sampling (PhD Thesis). Massachusetts Institute of Technology, Massachusetts, USA. http://dspace.mit.edu/handle/1721.1/38258

Besl PJ, McKay ND (1992) A method for registration of 3-D shapes. In: IEEE Transactions on Pattern Analysis and Machine Intelligence. 14(2):239–256

Yang C, Medioni G (1992) Object modeling by registration of multiple range images. Image Vis Comput 10(3):145–155

Mada SK, Smith ML, Smith LN, Midha PS (2003) Overview of passive and active vision techniques for hand-held 3D data acquisition. In: Shearer A, Murtagh FD, Mahon J, Whelan PF (eds) Opto-Ireland 2002: Optical metrology, imaging, and machine vision, Galway, Ireland, 2002. SPIE Digital Library. http://proceedings.spiedigitallibrary.org/proceeding.aspx?articleid=879224