Ablation Lesion Characterization in Scarred Substrate Assessed Using Cardiac Magnetic Resonance

JACC: Clinical Electrophysiology - Tập 5 - Trang 91-100 - 2019
Susumu Tao1, Michael A. Guttman1, Sarah Fink1, Hassan Elahi2, Kaustubha D. Patil1, Hiroshi Ashikaga1,2, Aravindan D. Kolandaivelu1, Ronald D. Berger1, Marc K. Halushka3, Ehud J. Schmidt1, Daniel A. Herzka2, Henry R. Halperin1,2,4
1Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
2Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
3Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
4Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA

Tài liệu tham khảo

Zipes, 2006, J Am Coll Cardiol, 48, e247, 10.1016/j.jacc.2006.07.010 Jaïs, 2012, Elimination of local abnormal ventricular activities: a new end point for substrate modification in patients with scar-related ventricular tachycardia, Circulation, 125, 2184, 10.1161/CIRCULATIONAHA.111.043216 Di Biase, 2012, Endo-epicardial homogenization of the scar versus limited substrate ablation for the treatment of electrical storms in patients with ischemic cardiomyopathy, J Am Coll Cardiol, 60, 132, 10.1016/j.jacc.2012.03.044 Stevenson, 2008, Irrigated radiofrequency catheter ablation guided by electroanatomic mapping for recurrent ventricular tachycardia after myocardial infarction: the Multicenter Thermocool Ventricular Tachycardia Ablation Trial, Circulation, 118, 2773, 10.1161/CIRCULATIONAHA.108.788604 Nazarian, 2009, Applications of cardiac magnetic resonance in electrophysiology, Circ Arrhythm Electrophysiol, 2, 63, 10.1161/CIRCEP.108.811562 Lardo, 2000, Visualization and temporal/spatial characterization of cardiac radiofrequency ablation lesions using magnetic resonance imaging, Circulation, 102, 698, 10.1161/01.CIR.102.6.698 Dickfeld, 2006, Characterization of radiofrequency ablation lesions with gadolinium-enhanced cardiovascular magnetic resonance imaging, J Am Coll Cardiol, 47, 370, 10.1016/j.jacc.2005.07.070 Ranjan, 2011, Gaps in the ablation line as a potential cause of recovery from electrical isolation and their visualization using MRI, Circ Arrhythm Electrophysiol, 4, 279, 10.1161/CIRCEP.110.960567 Dickfeld, 2007, Characterization of acute and subacute radiofrequency ablation lesions with nonenhanced magnetic resonance imaging, Heart Rhythm, 4, 208, 10.1016/j.hrthm.2006.10.019 Celik, 2014, Intrinsic contrast for characterization of acute radiofrequency ablation lesions, Circ Arrhythm Electrophysiol, 7, 718, 10.1161/CIRCEP.113.001163 Guttman, 2018, Non-contrast-enhanced T1-weighted MRI of myocardial radio-frequency ablation lesions, Magn Reson Med, 79, 879, 10.1002/mrm.26750 McGann, 2011, Dark regions of no-reflow on late gadolinium enhancement magnetic resonance imaging result in scar formation after atrial fibrillation ablation, J Am Coll Cardiol, 58, 177, 10.1016/j.jacc.2011.04.008 Ashikaga, 2007, Magnetic resonance-based anatomical analysis of scar-related ventricular tachycardia: implications for catheter ablation, Circ Res, 101, 939, 10.1161/CIRCRESAHA.107.158980 Bland, 1986, Statistical methods for assessing agreement between two methods of clinical measurement, Lancet, 1, 307, 10.1016/S0140-6736(86)90837-8 Aso, 1988, Effects of thermal denaturation on the longitudinal relaxation time (T1) of water protons in protein solutions: study of the factors determining the T1 of water protons, Magn Reson Imaging, 6, 17, 10.1016/0730-725X(88)90519-X Farahani, 1999, MRI of thermally denatured blood: methemoglobin formation and relaxation effects, Magn Reson Imaging, 17, 1489, 10.1016/S0730-725X(99)00094-6 Hartung, 1995, Estimation of temperature during radiofrequency catheter ablation using impedance measurements, Pacing Clin Electrophysiol, 18, 2017, 10.1111/j.1540-8159.1995.tb03862.x Wittkampf, 2006, RF catheter ablation: lessons on lesions, Pacing Clin Electrophysiol, 29, 1285, 10.1111/j.1540-8159.2006.00533.x Ikeda, 2014, Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart: electrogram amplitude, impedance, and electrode temperature are poor predictors of electrode-tissue contact force and lesion, Circ Arrhythm Electrophysiol, 7, 1174, 10.1161/CIRCEP.113.001094 Amorós-Figueras, 2018, Endocardial infarct scar recognition by myocardial electrical impedance is not influenced by changes in cardiac activation sequence, Heart Rhythm, 15, 589, 10.1016/j.hrthm.2017.11.031 Lustgarten, 2008, Ablation using irrigated radiofrequency: a hands-on guide, Heart Rhythm, 5, 899, 10.1016/j.hrthm.2008.01.003 An, 1989, Radiofrequency ablation of ventricular myocardium using active fixation and passive contact catheter delivery systems, Am Heart J, 118, 69, 10.1016/0002-8703(89)90074-4 Kottkamp, 1997, Subendocardial and intramural temperature response during radiofrequency catheter ablation in chronic myocardial infarction and normal myocardium, Circulation, 95, 2155, 10.1161/01.CIR.95.8.2155 Liu, 2006, Characterization of the RF ablation-induced “oven effect”: the importance of background tissue thermal conductivity on tissue heating, Int J Hyperthermia, 22, 327, 10.1080/02656730600609122 Wong, 2013, Characterization of catheter-tissue contact force during epicardial radiofrequency ablation in an ovine model, Circ Arrhythm Electrophysiol, 6, 1222, 10.1161/CIRCEP.113.000184 Aquaro, 2012, Fat in left ventricular myocardium assessed by steady-state free precession pulse sequences, Int J Cardiovasc Imaging, 28, 813, 10.1007/s10554-011-9886-2 Perazella, 2008, Gadolinium-contrast toxicity in patients with kidney disease: nephrotoxicity and nephrogenic systemic fibrosis, Curr Drug Saf, 3, 67, 10.2174/157488608783333989 Tschabrunn, 2016, A swine model of infarct-related reentrant ventricular tachycardia: electroanatomic, magnetic resonance, and histopathological characterization, Heart Rhythm, 13, 262, 10.1016/j.hrthm.2015.07.030