A technique for fast and accurate measurement of hand volumes using Archimedes’ principle

Springer Science and Business Media LLC - Tập 31 - Trang 56-59 - 2008
S. Hughes1, J. Lau1
1Department of Physical and Chemical Sciences, Queensland University of Technology, Brisbane, Australia

Tóm tắt

A new technique for measuring hand volumes using Archimedes principle is described. The technique involves the immersion of a hand in a water container placed on an electronic balance. The volume is given by the change in weight divided by the density of water. This technique was compared with the more conventional technique of immersing an object in a container with an overflow spout and collecting and weighing the volume of overflow water. The hand volume of two subjects was measured. Hand volumes were 494±6 ml and 312±7 ml for the immersion method and 476±14 ml and 302±8 ml for the overflow method for the two subjects respectively. Using plastic test objects, the mean difference between the actual and measured volume was -0.3% and 2.0% for the immersion and overflow techniques respectively. This study shows that hand volumes can be obtained more quickly than the overflow method. The technique could find an application in clinics where frequent hand volumes are required.

Tài liệu tham khảo

Perrin, M. and Guex, J.J.,Edema and leg volume: methods of assessment. Angiology 51:615–6, 2000. Sander, A.P., Hajer, N.M., Hemenway, K., Miller, A.C.,Upper-extremity volume measurements in women with lymphedema: A comparison of measurements obtained via water displacement with geometrically determined volume. Physical Therapy, 82:1201–1212, 2002. Farrell, K., Johnson, A., Duncan, H., Offenbacker, T., Curry, C.,The intertester and intratester reliability of hand volumetrics. Journal of Hand Therapy, 16:292–299, 2003. Megens, A.M., Harros, S.R., Kim-Sing, C., McKenzie, D.C.,Measurement of upper extremity volume in women after axillary dissection for breast cancer. Arch. Phys. Med. Rehabil. 82:1639–1644, 2001. Boland, R. and Adams, R.,Development and evaluation of precision forearm and hand volumeter and measuring cylinder. Journal of Hand Therapy, 9:349–358, 1996. Tierney, S., Aslam, M., Rennie, K., Grace, P.,Infrared optoelectronic volumetry, the ideal way to measure limb volume. Eur. J. Vasc. Endovas. Surg. 12:412–417, 1996. Hughes, S.W.,Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects. Physics Education, 40: 468–474, 2005. Tipler, P.A. and Mosca, G., Physics for scientists and Engineers, page 432, 2008, 6th edition. Pellechia, G.L.,Figure-of-eight method of measuring hand size: reliability and concurrent validity. Journal of Hand Therapy, 16:300–304, 2003. Lette, J.,A simple and innovative device to measure arm volume at home for patients with lymphedema after breast cancer. Journal of Clinical Oncology, 24:5434–5440, 2006. Lette, J., Lette, S. and Fraser, S.,Home volumetry foretells a new era of self-management for patients with lyphedema after breast cancer. Lymphology, 40:185–187, 2007.