A role for surface topography in creating and maintaining bone at titanium endosseous implants

Journal of Prosthetic Dentistry - Tập 84 Số 5 - Trang 522-534 - 2000
Lyndon F. Cooper1
1Department of Prosthodontics, School of Dentistry, The University of North Carolina at Chapel Hill, 27599-7450, USA.

Tóm tắt

Từ khóa


Tài liệu tham khảo

Cooper, 1998, Biologic determinants of bone formation for osseointegration: clues for future clinical improvements, J Prosthet Dent, 80, 439, 10.1016/S0022-3913(98)70009-5

Stanford, 1999, Toward an understanding of implant occlusion and strain adaptive bone modeling and remodeling, J Prosthet Dent, 81, 553, 10.1016/S0022-3913(99)70209-X

Masuda, 1998, Generalizations regarding the process and phenomenon of osseointegration. Part I. In vivo studies, Int J Oral Maxillofac Implants, 13, 17

Kieswetter, 1996, Surface roughness modulates the local production of growth factors and cytokines by osteoblast-like MG-63 cells, J Biomed Mater Res, 32, 55, 10.1002/(SICI)1097-4636(199609)32:1<55::AID-JBM7>3.0.CO;2-O

Roberts, 1988, Bone tissue interface, J Dent Educ, 52, 804

Garetto, 1995, Remodeling dynamics of bone supporting rigidly fixed titanium implants: a histomorphometric comparison in four species including humans, Implant Dent, 4, 235, 10.1097/00008505-199500440-00002

Albrektsson, 1981, Osseointegrated titanium implants, Acta Orthrop Scand, 2, 155, 10.3109/17453678108991776

Adell, 1981, A 15-year study of osseointegrated implants in the treatment of the edentulous jaw, Int J Oral Surg, 10, 387, 10.1016/S0300-9785(81)80077-4

Kasemo, 1983, Biocompatibility of titanium implants: surface science aspects, J Prosthet Dent, 49, 832, 10.1016/0022-3913(83)90359-1

Rostlund, 1990, Difference in tissue response to nitrogen-ion-implanted titanium and c.p. titanium in the abdominal wall of the rat, J Biomed Mater Res, 24, 847, 10.1002/jbm.820240705

Johansson, 1998, A quantitative comparison of machined commercially pure titanium and titanium-aluminum-vanadium implants in rabbit bone, Int J Oral Maxillofac Implants, 13, 315

Han, 1998, Quantitative and qualitative investigations of surface enlarged titanium and titanium alloy implants, Clin Oral Implants Res, 9, 1, 10.1034/j.1600-0501.1998.090101.x

Brunski, 1979, The influence of functional use of endosseous dental implants on the tissue-implant interface. I. Histological aspects, J Dent Res, 58, 1953, 10.1177/00220345790580100201

Soballe, 1992, Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions, J Orthop Res, 10, 285, 10.1002/jor.1100100216

Deporter, 1999, Five- to six-year results of a prospective clinical trial using the ENDOPORE dental implant and a mandibular overdenture, Clin Oral Implants Res, 10, 95, 10.1034/j.1600-0501.1999.100203.x

Smith, 1992, Dental implant materials. I. Some effects of preparative procedures on surface topography, J Biomed Mater Res, 25, 1069, 10.1002/jbm.820250903

Pilliar, 1998, Overview of surface variability of metallic endosseous dental implants: textured and porous surface-structured designs, Implant Dent, 7, 305, 10.1097/00008505-199807040-00009

Buser, 1991, Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs, J Biomed Mater Res, 25, 889, 10.1002/jbm.820250708

Larsson, 1996, Bone response to surface-modified titanium implants: studies on the early tissue response to machined and electropolished implants with different oxide thicknesses, Biomaterials, 17, 605, 10.1016/0142-9612(96)88711-4

Li, 1997, Surface-dimpled commercially pure titanium implant and bone ingrowth, Biomaterials, 18, 691, 10.1016/S0142-9612(96)00185-8

Deporter, 1996, A prospective clinical study in humans of an endosseous dental implant partially covered with a powder-sintered porous coating: 3-to 4-year results, Int J Oral Maxillofac Implants, 11, 87

Jansen, 1993, Application of magnetron sputtering for producing ceramic coatings on implant materials, Clin Oral Implants Res, 4, 28, 10.1034/j.1600-0501.1993.040104.x

Wong, 1995, Effect of surface topology on the osseointegration of implant materials in trabecular bone, J Biomed Mater Res, 29, 1567, 10.1002/jbm.820291213

Lifland, 1993, Mechanical properties of a Ti-6A1-4V dental implant produced by electro-discharge compaction, Clin Mater, 14, 13, 10.1016/0267-6605(93)90042-6

Drummond, 1995, A light and scanning electron microscopic evaluation of electro-discharge-compacted porous titanium implants in rabbit tibia, J Oral Implantol, 21, 295

Story, 1998, In vivo performance of a modified CSTi dental implant coating, Int J Oral Maxillofac Implants, 13, 749

Wennerberg, 1996

Wennerberg, 1992, An optical three-dimensional technique for topographical descriptions of surgical implants, J Biomed Eng, 14, 412, 10.1016/0141-5425(92)90087-2

Wennerberg, 1998, A histomorphometric evaluation of screw-shaped implants each prepared with two surface roughnesses, Clin Oral Implants Res, 9, 11, 10.1034/j.1600-0501.1998.090102.x

Yamanaka, 1992, Long term observations on removal torque of directly bone-anchored implants in man, 245

Skripitz, 1998, Tensile bond between bone and titanium: a reappraisal of osseointegration, Acta Orthop Scand, 69, 315, 10.3109/17453679809000938

Edwards, 1997, Mechanical and morphologic investigation of the tensile strength of a bone-hydroxyapatite interface, J Biomed Mater Res, 36, 454, 10.1002/(SICI)1097-4636(19970915)36:4<454::AID-JBM3>3.0.CO;2-D

Takatsuka, 1995, Bone-bonding behavior of titanium alloy evaluated mechanically with detaching failure load, J Biomed Mater Res, 29, 157, 10.1002/jbm.820290204

Blumenthal, 1989, Inhibiton of apatite formation by titanium and vanadium ions, J Biomed Mater Res, 23, 13, 10.1002/jbm.820231305

Bianco, 1996, Titanium serum and urine levels in rabbits with a titanium implant in the absence of wear, Biomaterials, 17, 1937, 10.1016/0142-9612(96)00023-3

Keller, 1985, Systemic effects of porous Ti dental implants, Dent Mater, 1, 41, 10.1016/S0109-5641(85)80022-1

Smith, 1997, Systemic metal ion levels in dental implant patients, Int J Oral Maxillofac Implants, 12, 828

Chen, 1998, Corrosion resistance and ion dissolution of titanium with different surface microroughness, Biomed Mater Eng, 8, 61

Kononen, 1992, Effect of surface processing on the attachment, orientation, and proliferation of human gingival fibroblasts on titanium, J Biomed Mater Res, 26, 1325, 10.1002/jbm.820261006

Bowers, 1992, Optimization of surface micromorphology for enhanced osteoblast responses in vitro, Int J Oral Maxillofac Implants, 7, 302

Stanford, 1994, Bone cell expression on titanium surfaces is altered by sterilization treatments, J Dent Res, 73, 1061, 10.1177/00220345940730050801

Mustafa, 2000, Attachment, proliferation, differentiation and production of TGF-*1 by human osteoblast-like cells on different titanium surfaces [abstract], J Dent Res, 79, 101

Lohmann, 2000, Maturation state determines the response of osteogenic cells to surface roughness an 1,25-dihydroxyvitamin D3, J Bone Miner Res, 15, 1169, 10.1359/jbmr.2000.15.6.1169

Hulshoff, 1995, Biological evaluation of the effect of magnetron sputtered Ca/P coatings on osteoblast-like cells in vitro, J Biomed Mater Res, 29, 967, 10.1002/jbm.820290808

Davies, 1998, Mechanisms of endosseous integration, Int J Prosthodont, 11, 391

Masuda, 1997, Cell and matrix reactions at titanium implants in surgically prepared rat tibiae, Int J Oral Maxillofac Implants, 12, 472

Nygren, 1997, The initial reactions of TiO2 with blood, J Biomed Mater Res, 15, 487, 10.1002/(SICI)1097-4636(19970315)34:4<487::AID-JBM9>3.0.CO;2-G

Suzuki, 1997, Effects of surface roughness of titanium implants on bone remodeling activity of femur in rabbits, Bone, 21, 507, 10.1016/S8756-3282(97)00204-4

Ellingsen, 1998, Surface configurations of dental implants, Periodontol 2000, 17, 36, 10.1111/j.1600-0757.1998.tb00121.x

Lazzara, 1999, A human histologic analysis of osseotite and machined surfaces using implants with 2 opposing surfaces, Int J Periodontics Restorative Dent, 19, 117

Trisi, 1999, A histometric comparison of smooth and rough titanium implants in human low-density jawbone, Int J Oral Maxillofac Implants, 14, 689

Wenneberg A, Ivanhoff CJ, Hallgren C, Widmark G, Sennerby L. A histomorphometrical evaluation of blasted and turned c.p. Ti micro-implants inserted in human bone. Clin Oral Implants Res [in press].

Groessner-Schreiber, 1992, Enhanced extracellular matrix production and mineralization by osteoblasts cultured on titanium surfaces in vitro, J Cell Sci, 101, 209

Degasne, 1999, Effects of roughness, fibronectin and vitronectin on attachment, spreading, and proliferation of human osteoblast-like cells (Saos-2) on titanium surfaces, Calcif Tissue Int, 64, 499, 10.1007/s002239900640

Martin, 1995, Effect of titanium surface roughness on proliferation, differentiation, and protein synthesis of human osteoblast-like cells (MG63), J Biomed Mater Res, 29, 389, 10.1002/jbm.820290314

Anselme, 2000, Qualitative and quantitative study of human osteoblast adhesion on materials with various surface roughnesses, J Biomed Mater Res, 49, 155, 10.1002/(SICI)1097-4636(200002)49:2<155::AID-JBM2>3.0.CO;2-J

Cooper, 1999, Formation of mineralizing osteoblast cultures on machined, titanium oxide grit-blasted, and plasma-sprayed titanium surfaces, Int J Oral Maxillofac Implants, 14, 37

Schneider, 1994, Formation of focal adhesions by osteoblasts adhering to different substrata, Exp Cell Res, 214, 264, 10.1006/excr.1994.1257

Sinha, 1996, Regulation of human osteoblast integrin expression by orthopedic implant materials, Bone, 18, 451, 10.1016/8756-3282(96)00044-0

Healy, 1999, Designing biomaterials to direct biological responses, Ann N Y Acad Sci, 18, 24, 10.1111/j.1749-6632.1999.tb08491.x

Nanci, 1998, Chemical modification of titanium surfaces for covalent attachment of biological molecules, J Biomed Mater Res, 40, 324, 10.1002/(SICI)1097-4636(199805)40:2<324::AID-JBM18>3.0.CO;2-L

Schwartz, 1997, Underlying mechanisms at the bone-surface interface during regeneration, J Periodontal Res, 32, 166, 10.1111/j.1600-0765.1997.tb01399.x

Boyan, 1999, Surface roughness mediates its effects on osteoblasts via protein kinase A and phospholipase A2, Biomaterials, 20, 2305, 10.1016/S0142-9612(99)00159-3

Batzer, 1998, Prostaglandins mediate the effects of titanium surface roughness on MG63 osteoblast-like cells and alter cell responsiveness to 1 alpha,25-(OH)2D3, J Biomed Mater Res, 41, 489, 10.1002/(SICI)1097-4636(19980905)41:3<489::AID-JBM20>3.0.CO;2-C

Clokie, 1995, Morphologic and radioautographic studies of bone formation in relation to titanium implants using the rat tibia as a model, Int J Oral Maxillofac Implants, 10, 155

Ohtsu, 1997, A histological investigation on tissue responses to titanium implants in cortical bone of the rat femur, J Periodontol, 68, 270, 10.1902/jop.1997.68.3.270

Brunski, 2000, Biomaterials and biomechanics of oral and maxillofacial implants: current status and future developments, Int J Oral Maxillofac Implants, 15, 15

Wennerberg, 1997, A 1-year follow-up of implants of differing surface roughness placed in rabbit, Int J Oral Maxillofac Implants, 12, 486

Cole, 1997, Use of bone morphogenetic protein 2 on ectopic porous coated implants in the rat, Clin Orthop, 345, 219, 10.1097/00003086-199712000-00032

Bessho, 1999, BMP stimulation of bone response adjacent to titanium implants in vivo, Clin Oral Implants Res, 10, 212, 10.1034/j.1600-0501.1999.100304.x

Cochran, 1999, Recombinant human bone morphogenetic protein-2 stimulation of bone formation around endosseous dental implants, J Periodontol, 70, 139, 10.1902/jop.1999.70.2.139

Lind, 2000, Osteogenic protein 1 device stimulates bone healing to hydroxyapatite-coated and titanium implants, J Arthroplasty, 15, 339, 10.1016/S0883-5403(00)90693-4

Boden, 1998, Laparoscopic anterior spinal arthrodesis with rhBMP-2 in a titanium interbody threaded cage, J Spinal Disord, 11, 95, 10.1097/00002517-199804000-00001

Ong, 1997, Osteoblast responses to BMP-2-treated titanium in vitro, Int J Oral Maxillofac Implants, 12, 649

Shah, 1999, Mechanism of BMP-2 stimulated adhesion of osteoblastic cells to titanium alloy, Biol Cell, 91, 131, 10.1016/S0248-4900(99)80037-9

Hansson, 1999, The relation between surface roughness and inter-facial shear strength for bone-anchored implants. A mathematical model, J Biomech, 32, 829, 10.1016/S0021-9290(99)00058-5

Cochran, 1996, Evaluation of an endosseous titanium implant with a sand-blasted and acid-etched surface in the canine mandible: radiographic results, Clin Oral Implants Res, 7, 240, 10.1034/j.1600-0501.1996.070306.x

Feighan, 1995, The influence of surface-blasting on the incorporation of titanium-alloy implants in a rabbit intramedullary model, J Bone Joint Surg Am, 77, 1380, 10.2106/00004623-199509000-00015

Quirynen, 1993, An in vivo study of the influence of the surface roughness of implants on the microbiology of supra- and subgingival plaque, J Dent Res, 72, 1304, 10.1177/00220345930720090801

Rimondini, 1997, The effect of surface roughness on early in vivo plaque colonization on titanium, J Periodontol, 68, 556, 10.1902/jop.1997.68.6.556

Bollen, 1996, The influence of abutment surface roughness on plaque accumulation and peri-implant mucositis, Clin Oral Implants Res, 7, 201, 10.1034/j.1600-0501.1996.070302.x

Quirynen, 1996, The influence of titanium abutment surface roughness on plaque accumulation and gingivitis: short-term observations, Int J Oral Maxillofac Implants, 11, 169

Lekholm, 1996, Soft tissue and marginal bone conditions at osseointegrated implants that have exposed threads: a 5-year retrospective study, Int J Oral Maxillofac Implants, 11, 599

Wheeler, 1996, Eight-year clinical retrospective study of titanium plasma-sprayed and hydroxyapatite-coated cylinder implants, Int J Oral Maxillofac Implants, 11, 340

Edge, 1988, In vivo fracture of the tricalcium phosphate coating from the titanium body of an osseointegrating-type dental implant: a case report, Int J Oral Maxillofac Implants, 3, 57

Wang, 1999, Metal debris from titanium spinal implants, Spine, 24, 899, 10.1097/00007632-199905010-00011

La Budde, 1994, Particulate titanium and cobalt-chrome metallic debris in failed total knee arthroplasty. A quantitative histologic analysis, J Arthroplasty, 9, 291, 10.1016/0883-5403(94)90084-1

Liao, 1997, Stability of hydroxyapatite-coatings on titanium oral implants (IMZ). 2 retrieved cases, Clin Oral Implants Res, 8, 68, 10.1111/j.1600-0501.1997.tb00009.x

Schliephake, 1993, Metal release from titanium fixtures during placement in the mandible: an experimental study, Int J Oral Maxillofac Implants, 8, 502

Luthy, 1987, Analysis of plasma flame-sprayed coatings on endosseous oral titanium implants exfoliated in man: preliminary results, Int J Oral Maxillofac Implants, 2, 197

Osborn, 1990, The release of titanium into human bone form a titanium implant coated with plasma sprayed titanium, Adv Biomater, 9, 75

Goodman, 1996, Polyethylene and titanium alloy particles reduce bone formation. Dose-dependence in bone harvest chamber experiments in rabbits, Acta Orthop Scand, 67, 599, 10.3109/17453679608997764

Torgersen, 1995, Metal particles and tissue changes adjacent to miniplates. A retrieval study, Acta Odontol Scand, 53, 65, 10.3109/00016359509005948

Santavirta, 1991, Immunopathological response to loose cementless acetabular components, J Bone Joint Surg Br, 73, 38, 10.1302/0301-620X.73B1.1991772

Kovacs, 1994, Fibrogenic cytokines and connective tissue production, FASEB J, 8, 854, 10.1096/fasebj.8.11.7520879

Haas, 1996, Survival of 1,920 IMZ implants followed for up to 100 months, Int J Oral Maxillofac Implants, 11, 581

Babbush, 1993, Five-year statistical and clinical observations with the IMZ two-stage osseointegrated implant system, Int J Oral Maxillofac Implants, 8, 245

Meredith, 1998, A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants, Crit Rev Biomed Eng, 26, 275, 10.1615/CritRevBiomedEng.v26.i4.20

Ramp, 2000, Assessment of osseointegration by nonlinear dynamic response, Int J Oral Maxillofac Implants, 15, 197

Rasmusson, 1998, Stability assessments and histology of titanium implants placed simultaneously with autogenous onlay bone in the rabbit tibia, Int J Oral Maxillofac Surg, 27, 229, 10.1016/S0901-5027(98)80019-2

Hammerle, 1996, The effect of subcrestal placement of the polished surface of ITI implants on marginal soft and hard tissues, Clin Oral Implants Res, 7, 111, 10.1034/j.1600-0501.1996.070204.x

Vaillancourt, 1996, Factors affecting crestal bone loss with dental implants partially covered with a porous coating: a finite element analysis, Int J Oral Maxillofac Implants, 11, 351

Levy, 1996, Periodontal parameters around porous-coated dental implants after 3 to 4 years supporting overdentures, J Clin Periodontol, 23, 517, 10.1111/j.1600-051X.1996.tb01819.x

Karlsson, 1997, Single-tooth replacement by osseointegrated Astra Tech dental implants: a 2-year report, Int J Prosthodont, 10, 318

Norton, 1998, Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro- and microstructure, Clin Oral Implants Res, 9, 91, 10.1034/j.1600-0501.1998.090204.x

Palmer, 1997, A prospective study of Astra single tooth implants, Clin Oral Implants Res, 8, 173, 10.1034/j.1600-0501.1997.080303.x

Kemppainen, 1997, A comparative prospective clinical study of two single-tooth implants: a preliminary report of 102 implants, J Prosthet Dent, 77, 382, 10.1016/S0022-3913(97)70163-X

Hansson, 1999, The implant neck: smooth or provided with retention elements. A biomechanical approach, Clin Oral Implants Res, 10, 394, 10.1034/j.1600-0501.1999.100506.x

Wiskott, 1999, Lack of integration of smooth titanium surfaces: a working hypothesis based on strains in the surrounding bone, Clin Oral Implants Res, 10, 429, 10.1034/j.1600-0501.1999.100601.x

Froum, 2000

Cochran, 1999, A comparison of endosseous dental implant surfaces, J Periodontol, 70, 1523, 10.1902/jop.1999.70.12.1523

Karabuda, 1999, Histologic and histomorphometric comparison of immediately placed hydroxyapatite-coated titanium plasma-sprayed implants: a pilot study in dogs, Int J Oral Maxillofac Implants, 14, 510

Cochran, 1998, Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etchedsurface: a histometric study in the canine mandible, J Biomed Mater Res, 40, 1, 10.1002/(SICI)1097-4636(199804)40:1<1::AID-JBM1>3.0.CO;2-Q

D'Lima, 1998, Bone response to implant surface morphology, J Arthroplasty, 13, 928, 10.1016/S0883-5403(98)90201-7

Jinno, 1998, Osseointegration of surface-blasted implants made of titanium alloy and cobalt-chromium alloy in a rabbit intramedullary model, J Biomed Mater Res, 42, 20, 10.1002/(SICI)1097-4636(199810)42:1<20::AID-JBM4>3.0.CO;2-Q

Pebe, 1997, Countertorque testing and histomorphometric analysis of various implant surfaces in canines: a pilot study, Implant Dent, 6, 259, 10.1097/00008505-199700640-00002

Wennerberg, 1996, Torque and histomorphometric evaluation of c.p. titanium screws blasted with 25- and 75-microns-sized particles of Al2O3, J Biomed Mater Res, 30, 251, 10.1002/(SICI)1097-4636(199602)30:2<251::AID-JBM16>3.0.CO;2-P

Hure, 1996, Does titanium surface treatment influence the bone-implant interface? SEM and histomorphometry in a 6-month sheep study, Int J Oral Maxillofac Implants, 11, 506

Wennerberg, 1996, Experimental study of turned and grit-blasted screw-shaped implants with special emphasis on effects of blasting material and surface topography, Biomaterials, 17, 15, 10.1016/0142-9612(96)80750-2

Wennerberg, 1996, Bone tissue response to commercially pure titanium implants blasted with fine and coarse particles of aluminum oxide, Int J Oral Maxillofac Implants, 11, 38

Wennerberg, 1995, A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies, Clin Oral Implants Res, 6, 24, 10.1034/j.1600-0501.1995.060103.x

Gotfredsen, 1995, Anchorage of TiO2-blasted, HA-coated, and machined implants: an experimental study with rabbits, J Biomed Mater Res, 29, 1223, 10.1002/jbm.820291009

Ericsson, 1994, A histomorphometric evaluation of bone-to-implant contact on machine-prepared and roughened titanium dental implants. A pilot study in the dog, Clin Oral Implants Res, 5, 202, 10.1034/j.1600-0501.1994.050402.x

Abron A, Hopfensperger M, Thompson J, Cooper LF. Evaluation of a predictive model for implant surface topography effects on early osseointegration in the rat tibia model. J Prosthet Dent [in press].

Klokkevold, 1997, Osseointegration enhanced by chemical etching of the titanium surface. A torque removal study in the rabbit, Clin Oral Implants Res, 8, 442, 10.1034/j.1600-0501.1997.080601.x

Buser, 1998, Removal torque values of titanium implants in the maxilla of miniature pigs, Int J Oral Maxillofac Implants, 13, 611

Li, 1997, Bone-implant interface and remaining tissues on the implant surface after push-out test: an SEM observation, Biomed Mater Eng, 7, 379

Baker, 1999, Rate of pull-out strength gain of dual-etched titanium implants: a comparative study in rabbits, Int J Oral Maxillofac Implants, 14, 722

Buser, 1999, Interface shear strength of titanium implants with a sandblasted and acid-etched surface: a biomechanical study in the maxilla of miniature pigs, J Biomed Mater Res, 45, 75, 10.1002/(SICI)1097-4636(199905)45:2<75::AID-JBM1>3.0.CO;2-P