A primary current distribution model of a novel micro-electroporation channel configuration

Springer Science and Business Media LLC - Tập 12 - Trang 833-840 - 2010
Gregory D. Troszak1, Boris Rubinsky2
1Department of Mechanical Engineering, University of California, Berkeley, Berkeley, USA
2Department of Mechanical Engineering and Bioengineering, University of California – Berkeley, Berkeley, USA

Tóm tắt

Traditional macro and micro-electroporation devices utilize facing electrodes, which generate electric fields inversely proportional to their separation distance. Although the separation distances in micro-electroporation devices are significantly smaller than those in macro-electroporation devices, they are limited by cell size. Because of this, significant potential differences are required to induce electroporation. These potential differences are often large enough to cause water electrolysis, resulting in electrode depletion and bubble formation, both of which adversely affect the electroporation process. Here, we present a theoretical study of a novel micro-electroporation channel composed of an electrolyte flowing over a series of adjacent electrodes separated by infinitesimally small insulators. Application of a small, non-electrolysis inducing potential difference between the adjacent electrodes results in radially-varying electric fields that emanate from these insulators, causing cells flowing through the channel to experience a pulsed electric field. This eliminates the need for a pulse generator, making a minimal power source (such as a battery) the only electrical equipment that is needed. A non-dimensional primary current distribution model of the novel micro-electroporation channel shows that decreasing the channel height results in an exponential increase in the electric field magnitude, and that cells experience exponentially greater electric field magnitudes the closer they are to the channel walls. Finally, dimensional primary current distribution models of two potential applications, water sterilization and cell transfection, demonstrate the practical feasibility of the novel micro-electroporation channel.

Tài liệu tham khảo

B. Alberts, A. Johnson, J. Lewis, M. Raff, K. Roberts, P. Waiter, Molecular Biology of the Cell, 4th edn. (Garland, New York, 2007) G.L. Andreason, Tiss. J. Cult. Meth. 15, 56–62 (1993) Diarrhoeal diseases. (World Health Organization, 2009), http://www.who.int/vaccine_research/diseases/diarrhoeal/en/print.html. Accessed 12 April 2010 M.B. Fox, D.C. Esveld, A. Valero, R. Luttge, H.C. Mastwijk, P.V. Bartels, A. van der Berg, R.M. Boom, Anal. Bioanal. Chem. 385(3), 474–485 (2006) Global water supply and sanitation assessment report. (World Health Organization/United Nations Children’s Fund, Water Supply and Sanitation Collaborative Council, 2000), http://www.who.int/docstore/water_sanitation_health/Globassessment/GlobalTOC.htm. Accessed 12 April 2010 S.Y. Ho, G.S. Mittal, Crit. Rev. Biotechnol. 16(4), 349–362 (1996) S.Y. Ho, G.S. Mitall, J.D. Cross, J. Food Eng. 31(1), 69–84 (1997) Y. Huang, B. Rubinsky, Biomed. Microdevices 2(2), 145–150 (1999) D. Knorr, A. Angersbach, M.N. Eshtiaghi, V. Heinz, D. Lee, Trends Food Sci. Tech. 12(3–4), 129–135 (2001) H.C. Mastwijk, P.V. Bartels, Int. Rev. Food Sci. Technol. 3, 106–108 (2004) G.L. Prasanna, T. Panda, Bioprocess Biosyst. Eng. 16(5), 261–264 (1997) G. Prentice, Electrochemical Engineering Principles, 1st edn. (Prentice, Upper Saddle River, 1991) A.J.H. Sale, W.A. Hamilton, Biochim. Biophys. 148(3), 781–788 (1967) I.P. Sugar, W. Förster, E. Neumann, Biophys. Chem. 26(3), 321–335 (1987) T.Y. Tsong, K. Kinosita, Bibl. Haematol. 51, 108–114 (1985) J.C. Weaver, Y.A. Chizmadzhev, Bioelectrochem. Bioenerg. 41(2), 135–160 (1996) T. Wong, E. Neumann, Biochem. Biophys. Res. Commun. 107(2), 584–587 (1982) P.C. Wouters, N. Dutreux, J.P.P.M. Smelt, H.L.M. Lelieveld, Appl. Environ. Microbiol. 65(12), 5364–5371 (1999)