A phantom for dosimetric characterization of small radiation fields: design and use

Medical Dosimetry - Tập 25 - Trang 9-15 - 2000
J Kalef-Ezra1, M Bazioglou1,2, K Theodorou2, C Kappas2
1Medical Physics Department, Medical School, University of Ioannina, 451.10 Ioannina, Hellas Greece
2Medical Physics Department, Medical School, University of Patras, 265.00 Patra, Hellas Greece

Tài liệu tham khảo

Bjärngard, 1990, Doses on the central axis of narrow 6-MV x-ray beams, Med. Phys., 17, 794, 10.1118/1.596475 Schell, M.C.; Bova, F.J.; Larson, D.D.; Leavitt, D.D.; Lutz, W.R.; Podgorsak, E.B.; Wu, A. Stereotactic Radiosurgery, AAPM Report 54. Woodbury, NY: American Institute of Physics; 1995. Houdek, 1983, Dosimetry of small radiation fields for 10 MV x rays, Med. Phys., 19, 333, 10.1118/1.595262 Arcovito, 1985, Dose measurements and calculations of small radiation fields for 9-MV x rays, Med. Phys., 12, 779, 10.1118/1.595664 Rice, 1987, Measurement of dose distributions in small beams of 6 MV x-rays, Phys. Med. Biol., 32, 1087, 10.1088/0031-9155/32/9/002 Wu, 1990, Physics of gamma knife approach on convergent beams in stereotactic radiosurgery, Int. J. Radiat. Oncol. Biol. Phys., 18, 941, 10.1016/0360-3016(90)90421-F Serago, 1992, Tissue maximum ratios (and other parameters) of small circular 4, 6, 19, 15 and 24 MV x-ray beams for radiosurgery, Phys. Med. Biol., 37, 1943, 10.1088/0031-9155/37/10/010 O’Brien, 1994, Measured spatial accuracy for linac based-radiosurgery, Med. Phys., 21, 1145, 10.1118/1.597341 Duftschmid, K.E.; Kindl, P.; Obenaus, B.; Strachotinsky, Ch.; Winker, N. Precision dosimetry in narrow collimated radiation beams of the Leksell Gamma Knife. Radiat Protect Dosim66:295–298; 1996. Heydarian, 1996, A comparison of dosimetry techniques in stereotactic radiosurgery, Phys. Med. Biol., 41, 93, 10.1088/0031-9155/41/1/008 Ertl, 1996, TLD array for precise dose measurements in stereotactic radiation techniques, Phys. Med. Biol., 41, 2679, 10.1088/0031-9155/41/12/007 Rustgi, 1994, Dosimetric characterization of radiosurgical beams with diamond detector. (abstract), Med. Phys., 22, 890 Das, 1996, Characteristics of dedicated linear accelerator-based stereotactic radiosurgery-radiotherapy unit, Radiother. Oncol., 38, 61, 10.1016/0167-8140(95)01674-0 Beddar, 1992, Dosimetry of stereotactic radiation fields using miniature plastic scintillation detectors. (abstract), Med. Phys., 19, 790 McGinley, 1992, An adjustable collimator for stereotactic radiosurgery, Phys. Med. Biol., 37, 413, 10.1088/0031-9155/37/2/008 Chierego, 1993, From radiotherapy to stereotactic radiotherapy, Radiother. Oncol., 29, 214, 10.1016/0167-8140(93)90249-8 Gotoh, 1996, Narrow photon beam dosimetry for linear accelerator radiosurgery, Radiother. Oncol., 41, 221, 10.1016/S0167-8140(96)01843-9 McLaughlin, 1994, The use of radiochromic detectors for the determination of stereotactic radiosurgery dose characteristics, Med. Phys., 21, 379, 10.1118/1.597384 Ramani, 1994, The use of radio-chromic film in treatment verification of dynamic radiosurgery, Med. Phys., 21, 389, 10.1118/1.597385 Guan, 1993, Imaging of radiation doses for stereotactic radiosurgery, Med. Dosim., 18, 135, 10.1016/S0958-3947(06)80008-7 Schulz, 1993, Assessment of the accuracy of stereotactic radiosurgery using Fricke-infused gels and MRI, Med. Phys., 20, 1731, 10.1118/1.597126 Maryanski, 1996, Radiation therapy dosimetry using magnetic resonance imaging of polymer gels, Med. Phys., 23, 699, 10.1118/1.597717 Fairchild, R.G.; Kalef-Ezra, J.; Packer, S.; Wielopolski, L.; Laster, B.H.; Robertson, J.S.; et al. Samarium 145: A new brachytherapy source. Phys. Med. Biol.32:847–858; 1987. Kron, 1993, Thermoluminescent dosimetry of therapeutic x-rays with LiF ribbons and rods, Phys. Med. Biol., 38, 833, 10.1088/0031-9155/38/6/014 Kalef-Ezra, J.; Stamatelatos, I.; Kamenopoulou, A.; Bazioglou, M. Manual TLD readers: Comparison of three systems. Proceedings of the 1st Mediterranean Congress on Radiation Protection. 73–76, Athens; Greek Radiation Protection Association; 1994. Kappas, C.; Theodorou, K.; Kardamakis, D.; Dimopoulos, I.; Papadakis, N.; Proimos, B. Design, construction and installation of a new stereotactic system for single dose and fractionated radiotherapy. Physica Medica XIII: 123–128; 1997. Mazal, D.A. Radiotherapie stereotaxique par petites faisceaux de rayons X de haute energie. Doctoratate de l’ Univesrité Paul Sabatier de Toulouse (Sciences); 1990. Wu, 1993, Comments on dose measurements for a narrow beam in radiosurgery, Med. Phys., 20, 777, 10.1118/1.597032