A performance based methodology for fire design of restrained steel beams
Tài liệu tham khảo
AISC. Steel construction manual. 13th ed. Chicago (IL): American Institute of Steel Construction, Inc.; 2005.
Eurocode 3. EN1993-1-2: the European standard; part 1–2: general rules—structural fire design. Brussels (Belgium): European Committee for Standardization; 2005.
ASCE. Structural fire protection. Manual no. 78, ASCE committee on fire protection, structural division. New York (NY): American Society of Civil Engineers; 1992.
Kirby BR. Large scale fire tests: the British steel European collaborative research programme on the BRE 8-storey frame. In: Proceedings of the Fifth International Symposium of Fire Safety Science. 1997. p. 1129–40.
Newman GM, Robinson JT, Bailey CG. Fire safety design: a new approach to multi-storey steel framed buildings. SCI Publications P288. The Steel Construction Institute. 2000.
Wang, 2000, Research towards use of unprotected steel structures, ASCE Journal of Structural Engineering, 126, 1442, 10.1061/(ASCE)0733-9445(2000)126:12(1442)
Wang, 2000, An analysis of the global structural behaviour of the Cardington steel-framed building during the two BRE fire tests, Engineering Structures, 22, 401, 10.1016/S0141-0296(98)00127-8
Skowronski, 1988, A study of the steel beam deformations during fire, Building and Environment, 23, 159, 10.1016/0360-1323(88)90030-3
Skowronski, 1990, Load capacity and deflection of fire-resistant steel beams, Fire Technology, 310, 10.1007/BF01293076
BS 476-3: 1987. Fire tests on building materials and structures—part 20: method for determination of the fire resistance of elements of construction, general principles. London (UK); 1987.
Li, 2000, Fire-resistant experiment and theoretical calculation of a steel beam, China Civil Engineering Journal, 32, 23
Liu, 2002, Experimental investigation of behaviour of axially restrained steel beams in fire, Journal of Constructional Steel Research, 58, 1211, 10.1016/S0143-974X(01)00062-1
Li, 2008, Experiment on restrained steel beams subjected to heating and cooling, Journal of Constructional Steel Research, 64, 268, 10.1016/j.jcsr.2007.07.007
Usmani, 2001, Fundamental principles of structural behaviour under thermal effects, Fire Safety Journal, 36, 721, 10.1016/S0379-7112(01)00037-6
Tan, 2005, Structural responses of axially restrained steel beams with semirigid moment connection in fire, Journal of Structural Engineering, 131, 541, 10.1061/(ASCE)0733-9445(2005)131:4(541)
Yin, 2003, Numerical simulations of the effects of non-uniform temperature distributions on lateral torsional buckling resistance of steel I-beam, Journal of Constructional Steel Research, 59, 1009, 10.1016/S0143-974X(03)00003-8
Wang, 2006, A simplified analysis of catenary action in steel beams in fire and implications on fire resistant design, Steel and Composite Structures, 6, 367, 10.12989/scs.2006.6.5.367
Dwaikat, 2009, Effect of location of restraint on fire response of steel beams, Journal of Fire Technology
Yang, 2006, Performance of steel H-columns loaded under uniform temperature, Journal of Constructional Steel Research, 62, 262, 10.1016/j.jcsr.2005.07.001
Dharma, 2007, Rotational capacity of steel I-beams under fire conditions, part I: experimental study, Engineering Structures, 29, 2391, 10.1016/j.engstruct.2006.11.031
Haaijer, 1958, On inelastic buckling in steel, Journal of Engineering Mechanics Division, ASCE, 84, 1581-1
Ghali, 2003
ANSYS. ANSYS multiphysics. Version 11.0 SP1 ANSYS Inc. Canonsburg (PA); 2007.
Kodur, 2009, Response of steel beam–columns exposed to fire, Engineering Structures, 31, 369, 10.1016/j.engstruct.2008.08.020
ASCE/SEI 7-05. Minimum design loads for buildings and other structures. ASCE Standard, Structural Engineering Institute, American Society of Civil Engineers. Reston (VA, US): ASCE; 2006. p. 424.