A novel buddy balloon technique to recross a T‐stented bifurcation

Catheterization and Cardiovascular Interventions - Tập 74 Số 1 - Trang 103-107 - 2009
Brendan Gunalingam1, Richard Y.J. Chan1
1Department of Cardiology, Gosford Hospital, Gosford, New South Wales, Australia

Tóm tắt

AbstractThe T technique is not uncommonly used to stent bifurcation lesions. It requires recrossing into the side branch with a guidewire and balloon to perform final Kissing Balloon dilations, but recrossing can be difficult. We describe a case of bifurcation stenting where balloon recrossing following guidewire placement into the side branch proved very challenging, and was finally achieved via a combination of forward pressure on a low‐profile balloon with its tip wedged at the stent struts along with simultaneous low‐pressure inflation of a larger parallel balloon. This altered the stent architecture and also allowed for a more favorable vector of force transmission to allow recrossing and hence successful completion of the procedure. © 2009 Wiley‐Liss, Inc.

Từ khóa


Tài liệu tham khảo

10.1111/j.1540-8183.2001.tb00375.x

Pendyala L, 2008, Review of percutaneous therapy for bifurcation lesions in the era of drug‐eluting stents, Minerva Cardioangiol, 56, 89

10.1016/j.jacc.2005.05.080

10.1161/01.CIR.0000118474.71662.E3

Pristipino C, 2006, Limitations of crush technique, J Am Coll Cardiol, 47, 1915, 10.1016/j.jacc.2006.02.011

10.1016/j.ahj.2006.10.017

10.1136/hrt.2005.061531

Nguyen T, 2003, Practical Handbook of Advanced Interventional Cardiology

Goldberg A, 2007, Buddy wire, buddy balloon or better together!, J Invasive Cardiol, 19, E363

10.1002/1522-726X(200011)51:3<312::AID-CCD15>3.0.CO;2-3

10.1002/ccd.10551

10.1002/ccd.20624

Kern MJ, 2006, SCAI Interventional Cardiology Board Review Book