A method for analyzing stability of tower-line system under strong winds

Advances in Engineering Software - Tập 127 - Trang 1-7 - 2019
Bo He1, Mingxi Zhao1, Wentao Feng1, Yaping Xiu2, Yu Wang3, Lijun Feng4, Yongjian Qin5, Chukun Wang5
1School of Electrical Engineering, State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Shaanxi, Xi'an 710049, China
2State Grid Shandong Power Company, Yantai Power Supply Company, Shandong, Yantai 264001, China
3State Grid Xi'an Electric Power Company, Shaanxi, Xi'an 710032, China
4State Grid Shanxi Electric Power Dispatch and Control Center, Shanxi, Taiyuan 030001, China
5State Grid Jiangxi Electric Power Economic Research Institute, Jiangxi, Nanchang 330043, China

Tài liệu tham khảo

Hu, 2014, Analysis of influential factors on operation safety of transmission line and countermeasures, High Voltage Eng, 40, 3491 Tianwei, 2016, Wind accident analysis of southern grid coastal region transmission line, High Voltage Apparatus, 52, 23 Yang, 2010, Study on the limited values of foundation deformation for a typical UHV transmission tower, IEEE Trans Power Deliv, 25, 2752, 10.1109/TPWRD.2010.2045662 Gupta, 1994, Structural failure analysis of 345 kV transmission line, IEEE Trans Power Deliv, 9, 894, 10.1109/61.296272 Yu, 2016, Collapse-resistant performance of super-large cooling towers subjected to seismic actions, Eng Struct, 108, 77, 10.1016/j.engstruct.2015.11.023 Fei, 2012, Structural health monitoring oriented stability and dynamic analysis of a long-span transmission tower-line system, Eng Fail Anal, 20, 80, 10.1016/j.engfailanal.2011.11.001 Wang, 2015, Review on the impact of typhoon on the transmission line and the measures of anti-typhoon, Mod Ind Econ Inform, 5, 67 Hossein, 2016, Influence of partial undergrounding on the transient stability of EHV power transmission systems, Electric Power Syst Res, 131, 126, 10.1016/j.epsr.2015.10.002 Liao, 2011, Contrast analysis of wind loading calculation of IEC, ASCE and GB50545 criterion, Electric Power Surv Des, 6, 59 2006 2009 2003 Lilien, 2011, Galloping data base on singleand bundle conductors prediction of maximum amplitudes, IEEE Trans Power Deliv, 31, 102 Maeno, 1984, Dynamic properties of UHV power transmission towers: full-scale tests and numerical investigation Liang, 2015, Investigation on wind tunnel tests of a full aeroelastic model of electrical transmission tower-line system, Eng Struct, 85, 63, 10.1016/j.engstruct.2014.11.042 Mahadevan, 2000, Adaptive simulation for system reliability analysis of large structure, Comput Struct, 77, 725, 10.1016/S0045-7949(00)00013-4 Rao, 2012, Studies on failure of transmission line towers in testing, Eng Struct, 35, 55, 10.1016/j.engstruct.2011.10.017 Safi, 2004, Spectral dynamic analysis of power transmission towers using ANN imperfection Simulator, IEEE Trans Power Deliv, 19, 1907, 10.1109/TPWRD.2004.832394 Aiqiang, 2010, Analysis of 3-D dynamic characteristics of high-voltage long-span transmission tower-line system, China Civil Eng J, 43, 224 Fu, 2016, Dynamic analysis of transmission tower-line system subjected to wind and rain loads, J Wind Eng Ind Aerodyn, 157, 95, 10.1016/j.jweia.2016.08.010 Deng, 2013, Wind tunnel study on wind-induced vibration responses of a UHV transmission tower-line system, Adv Struct Eng, 16, 1175, 10.1260/1369-4332.16.7.1175 Yang, 2016, Nonlinear inelastic responses of transmission tower-line system under downburst wind, Eng Struct, 123, 490, 10.1016/j.engstruct.2016.05.047 Shi, 2015, Geometric nonlinear static and dynamic analysis of guyed towers using fully nonlinear element formulations, Eng Struct, 99, 492, 10.1016/j.engstruct.2015.05.023 Belloli, 2010, Numerical analysis of the dynamic response of a 5-conductor expanded bundle subjected to turbulent wind, IEEE Trans Power Deliv, 25, 3105, 10.1109/TPWRD.2010.2056396 Xie, 2017, Wind-induced vibration of UHV transmission tower line system: wind tunnel test on aero-elastic model, J Wind Eng Ind Aerodyn, 171, 219, 10.1016/j.jweia.2017.10.011 Hamada, 2010, Finite element modeling of transmission line structures under tornado wind loading, Wind Struct, 13, 451, 10.12989/was.2010.13.5.451 An, 2005, A comparison of methods of extreme wind speed estimation, J Wind Eng Ind Aerodyn, 93, 535, 10.1016/j.jweia.2005.05.003 GB50545 (2010), “Code for design of 110 kV–750 kV overhead transmission lines”, Beijing.