Abstract  Considerable scientific and technological efforts have been devoted to develop neuroprostheses and hybrid bionic systems that link the human nervous system with electronic or robotic prostheses, with the main aim of restoring motor and sensory functions in disabled patients. A number of neuroprostheses use interfaces with peripheral nerves or muscles for neuromuscular stimulation and signal recording. Herein, we provide a critical overview of the peripheral interfaces available and trace their use from research to clinical application in controlling artificial and robotic prostheses. The first section reviews the different types of non‐invasive and invasive electrodes, which include surface and muscular electrodes that can record EMG signals from and stimulate the underlying or implanted muscles. Extraneural electrodes, such as cuff and epineurial electrodes, provide simultaneous interface with many axons in the nerve, whereas intrafascicular, penetrating, and regenerative electrodes may contact small groups of axons within a nerve fascicle. Biological, technological, and material science issues are also reviewed relative to the problems of electrode design and tissue injury. The last section reviews different strategies for the use of information recorded from peripheral interfaces and the current state of control neuroprostheses and hybrid bionic systems.

Từ khóa


Tài liệu tham khảo

Agnew WF, 1990, Neural Prostheses: Fundamental Studies. Biophysics and Bioengineering Series.

10.1007/BF02364272

10.1109/10.284958

10.1097/00006123-200204000-00003

10.1016/S0165-0270(03)00143-2

10.1046/j.1525-1594.2002.06938.x

10.1177/00034894031120S905

10.1002/mus.880080303

10.1002/mus.880150308

Barry DT, 1986, Acoustic myography as a control signal for an externally powered prosthesis, Arch Phys Med Rehabil, 67, 267

10.1016/S1350-4533(01)00012-1

Birbaumer N, 2004, Neuroprothetics: Theory and Practice., 1146, 10.1142/9789812561763_0039

10.1016/S0165-0270(97)02225-5

10.1016/S0361-9230(99)00231-2

10.1109/TBME.2003.820321

10.1152/jn.2001.85.4.1585

10.1113/jphysiol.1972.sp009791

Brindley GS, 1973, Emptying the bladder by stimulating sacral ventral roots, J Physiol, 237, 15P

10.1038/sc.1994.126

Brindley GS, 1995, Neuroprostheses., 15

10.1136/jnnp.49.10.1104

Bronzino JD, 1995, Biomedical Engineering Handbook.

10.1111/j.1749-6632.1983.tb31628.x

10.1109/10.704871

Carpaneto J, 2003, A sensorised thumb for force closed‐loop control of hand neuroprostheses, IEEE Trans Rehabil Eng, 11, 346

CarrozzaMC CappielloG CavallaroE VecchiF MiceraS DarioP(2004). Design and control of an underactuated cybernetic artificial hand. 10th International Symposium on Robotics and Applications.

10.1046/j.1525-1594.2000.06569.x

10.1109/TBME.2003.816075

10.1109/TBME.2005.846711

10.1002/jbm.10099

10.1097/00002060-199811000-00013

Chapin JK, 2000, Neural Prosthesis for Restoration of Sensory and Motor Function, 10.1201/9781420039054

10.1097/00004691-199709000-00003

10.1109/10.909637

10.1109/10.740879

10.1242/dev.108.4.635

CoganSF LiuY‐P McCaffreyM TwardochUM(1993). Thin film hermetic coatings. Quarterly Progress Report NIH‐NINDS Neural Prosthesis Program No. 5 N44‐NS‐2‐2311.

10.1016/0925-4005(92)80041-U

10.1109/TBME.1980.326592

Creasey GH, 1993, Electrical stimulation of sacral roots for micturition after spinal cord injury, Urol Clin North Am, 20, 505, 10.1016/S0094-0143(21)00511-5

Creasey G, 1996, Electrical stimulation to restore respiration, J Rehabil Res Dev, 33, 123

10.1109/86.736149

De Luca CJ, 2002, Surface Electromyography: Detection and Recording.

10.1016/S0165-0270(96)00159-8

10.1016/0302-4598(92)87036-T

Dhillon GS, 2004, Residual function in peripheral nerve stumps of amputees: implications for neural control of artificial limbs, J Hand Surg [Am], 29, 605, 10.1016/j.jhsa.2004.02.006

10.1007/BF02478508

10.1038/nn947

10.1109/10.7273

10.1523/JNEUROSCI.06-06-01583.1986

Dupont‐Salter AC, 2004, First clinical experience with BION implants for therapeutic electrical stimulation, Neuromodulation, 7, 38, 10.1111/j.1525-1403.2004.04005.x

10.1109/TBME.1986.325892

EdellDJ DevaneyL DurfeeWK GleasonEF GleasonKK HerndonTO ThompsonCV WrightonMS(1993). Bioresistant integrated circuits. Quarterly Progress Report NIH‐NINDS Neural Prosthesis Program No. 9 NO1‐NS‐0‐2399.

10.1016/0168-9002(91)90289-3

EnglehartK(1998).Signal representation for classification of the transient myoelectric signal.PhD Thesis Fredericton NB Canada:University of New Brunswick.

10.1109/TBME.2003.813539

10.1109/10.76384

10.1007/s00221-004-1970-6

10.1212/WNL.53.4.666

10.1126/science.1925540

10.1016/0304-3940(91)90724-8

10.1016/S0165-0270(97)02243-7

10.1114/1.1349699

10.1114/1.1581292

10.1111/j.1540-8159.1986.tb06627.x

10.1016/S0165-0270(96)02202-9

Goodall EV, 1992, Separation of action potentials in multiunit intrafascicular recordings, IEEE Trans Biomed Eng, 38, 846

10.1109/TBME.1983.325041

10.1007/BF02364648

10.1109/TSMC.1975.5408479

10.1080/01616412.1997.11740820

10.1016/0141-5425(82)90021-8

10.1109/86.506402

10.1109/10.481985

10.1109/86.736150

Gross GW, 1991, Neural Networks: Concepts, Applications, and Implementations., 47

Haemmerle H, 2002, Biostability of micro‐photodiode arrays for subretinal implantation, Biomaterials, 23, 797, 10.1016/S0142-9612(01)00185-5

10.1002/mus.880160702

Hagbarth KE, 2002, Microelectrode recordings from human peripheral nerves (microneurography), Muscle Nerve, 11, S28, 10.1002/mus.10144

10.3109/00016488909127474

HanJ‐S SongW‐K KimJ‐S BangW‐C LeeH BienZ(2000).New EMG pattern recognition based on soft computing techniques and its application to control a rehabilitation robotic arm.IIZUKA2000 Int Conf Soft Computing Iizuka Fukuoka Japan.

10.1109/10.32102

10.3171/jns.1996.84.3.0415

10.1109/86.296345

10.1109/86.296346

10.1109/86.481970

10.1016/S0301-0082(98)00013-6

10.1109/10.284959

Hetke JF, 1990, Flexible miniature ribbon cables for long‐term connection to implantable sensors, Sensors Actuators, 21, 999, 10.1016/0924-4247(90)87076-U

Hewson DJ, 2003, Evolution in impedance at the electrode‐skin interface of two types of surface EMG electrodes during long‐term recordings, J Electromyogr Kinesiol, 13, 273, 10.1016/S1050-6411(02)00097-4

10.1055/s-2007-993372

Hoffer JA, 2001, Neural Prostheses for Restoration of Sensory and Motor Function., 139

10.1109/10.335862

10.1016/S0304-3940(99)00589-3

10.1109/10.204774

10.1016/j.medengphy.2004.03.003

JandersM EgertU StelzleM NischW(1996). Novel thin‐film titanium nitride micro‐electrodes with excellent charge transfer capability for cell stimulation and sensing applications. Proceedings of the 19th International Conference of the IEEE/EMBS pp1191–1193.

10.1109/TNSRE.2002.802851

10.1179/016164102101200294

Ji J, 1990, A scaled electronically‐configurable multichannel recording array, Sensors Actuators, 21, 589, 10.1016/0924-4247(89)80040-8

10.1016/0302-4598(92)80067-Q

10.1109/10.238465

10.1016/1350-4533(95)00003-6

10.1016/S0006-8993(97)00675-6

10.1109/10.52324

10.1016/0165-0270(89)90142-8

10.1046/j.1525-1594.2002.06933.x

Kiguchi K, 2003, An exoskeletal robot for human shoulder joint motion assist, IEEE/ASME Trans Mechatronics, 8, 125, 10.1109/TMECH.2003.809168

Kiguchi K, 2001, An exoskeletal robot for human elbow motion support‐sensor fusion, adaptation, and control, IEEE Trans Syst Man Cybern Part B: Cybernetics, 31, 353, 10.1109/3477.931520

Kilgore KL, 1997, An implanted upper‐extremity neuroprosthesis, J Bone Joint Surg Am, 79, 533, 10.2106/00004623-199704000-00008

10.1682/JRRD.2003.11.0457

10.1109/4.535406

Kipke DR, 2003, Silicon‐substrate intracortical microelectrode arrays for long‐term recording of neuronal spike activity in cerebral cortex, IEEE Trans Rehabil Eng, 11, 151

Klinge PM, 2001, Regeneration of a transected nerve by transplantation of spinal cord encapsulated in a vein, Neuroreport, 12, 1271, 10.1097/00001756-200105080-00043

10.1016/S0142-9612(00)00420-8

10.1109/86.808942

10.1109/10.293244

10.1109/10.256422

10.1002/mus.880121108

Krylow AM, 1995, The Handbook of Brain Theory and Neural Networks., 609

10.3109/03093640409167756

10.1016/j.biomaterials.2004.06.025

10.1007/s004010050907

10.1109/86.847817

10.1016/S0165-0270(03)00231-0

10.1109/TNSRE.2004.831491

10.1002/jbm.10303

10.1007/BF02368469

10.1114/1.1569266

10.1109/TBME.2004.827535

Liberson WT, 1961, Functional electrotherapy: stimulation of the peroneal nerve synchronized with the swing phase of hemiplegic patients, Arch Phys Med Rehabil, 42, 101

Llinás R, 1973, Brain Unit Activity During Behaviour., 105

10.1007/BF02442964

10.1016/0165-0270(95)00123-9

10.1016/S1350-4533(01)00011-X

10.1016/j.clinph.2004.07.028

10.1007/BF02368058

10.1114/1.35

10.1126/science.183.4124.547

10.1109/TNSRE.2004.827223

10.1097/00004691-199709000-00002

10.1109/10.301727

10.1016/S0165-0270(96)00111-2

10.1109/TBME.1976.324593

10.1152/jn.2000.83.1.611

10.1016/S0924-4247(01)00807-X

10.1109/10.930903

10.1016/S1350-4533(98)00017-4

10.1016/S1350-4533(99)00055-7

10.1109/51.982274

10.1007/BF02364479

10.1109/10.55638

10.1109/JSSC.1986.1052646

10.1109/T-ED.1985.22102

10.1109/10.83589

Naples GG, 1990, Neural Prostheses: Fundamental Studies, Biophysics and Bioengineering Series., 107

10.2106/00004623-198264010-00001

Navarro X, 1996, Peripheral nerve regeneration through microelectrode arrays based on silicon technology, Restor Neurol Neurosci, 9, 151

Navarro X, 1998, Stimulation and recording from regenerated peripheral nerves through polyimide sieve electrodes, J Peripher Nerv Syst, 2, 91

Navarro X, 2001, Selective fascicular stimulation of the rat sciatic nerve with mutipolar polyimide cuff electrodes, Restor Neurol Neurosci, 18, 9

10.1016/j.neuroscience.2004.07.017

Nelson HE, 1980, Electrode effectiveness during transcutaneous motor stimulation, Arch Phys Med Rehabil, 61, 73

10.1002/micr.1047

10.1038/35053191

Nielson KD, 1976, Peripheral nerve injury from implantation of chronic stimulating electrodes for pain control, Surg Neurol, 5, 51

NishikawaD IshikawaY YuW MaruishiM WatanabeI YokoiH ManoY KakazuY(2000). On‐line learning based EMG prosthetic hand. Electrophysiology and Kinesiology pp575–580.

Nishikawa D, 1999, IEEE IROS'99, Kyongju, 1592

10.1016/0006-8993(96)00321-6

Normann RA, 1998, A neural interface for a cortical vision prosthesis, Vision Res, 12, 2577

10.1113/jphysiol.1983.sp014873

10.1016/S1050-6411(99)00020-6

Patterson RP, 1993, The influence of electrode size and type on surface stimulation of the quadriceps, IEEE Trans Rehabil Eng, 1, 59, 10.1109/86.242409

10.1109/10.797992

Peckham HP, 1992, Neural Prostheses. Replacing Motor Function After Disease or Disability., 162

10.1109/86.867874

Peters A, 1991, The Fine Structure of the Nervous System: Neurons and Their Supporting Cells

Pfurtscheller G, 2000, Current trends in Graz Brain‐Computer Interface (BCI) research, IEEE Trans Rehabil Eng, 2, 216, 10.1109/86.847821

PineJ TaiY‐C BuzsakiG BraginA CarpiD(1994). The cultured neuron probe. Quarterly Progress Report NIH‐NINDS Neural Prosthesis Program No. 4 NO1‐NS‐3‐2393.

Popovic DB, 1992, Neural Prostheses Replacing Motor Function After Disease or Disability., 233

Popovic MB, 2003, Control of neural prostheses for grasping and reaching, Med Eng Phys, 12, 41, 10.1016/S1350-4533(02)00187-X

Popovic MR, 1998, Neural prostheses for spinal cord injured subjects, J Bioworld, 1, 6

Popovic D, 1993, Sensory nerve recording for closed‐loop control to restore motor functions, IEEE Trans Biomed Eng, 400, 1024, 10.1109/10.247801

10.1111/j.1469-7793.2001.0099b.x

10.1016/S1050-6411(00)00024-9

10.1007/978-3-7091-3271-5

10.1016/0142-9612(93)90183-3

10.1007/s00381-003-0859-1

10.1016/S0022-5347(01)65032-8

Riso RR, 1999, Strategies for providing upper extremity amputees with tactile and hand position feedback – moving closer to the bionic arm, Technol Health Care, 7, 401, 10.3233/THC-1999-7604

Roblee LS, 1990, Neural Prostheses: Fundamental Studies, Biophysics and Bioengineering Series., 26

10.1016/S0165-0270(00)00192-8

Rosen J, 2001, A myosignal‐based powered exoskeleton system, IEEE Trans Syst Man Cybern – Part A Systems Humans, 31

Rosen JM, 1990, Preliminary experiments in nerve regeneration through laser‐drilled holes in silicon chips, Restor Neurol Neurosci, 2, 89

10.1016/0141-5425(93)90039-2

10.1515/BMT.2004.019

10.1146/annurev.bioeng.4.020702.153427

10.1109/51.765188

10.1016/0956-5663(95)96802-6

Santa‐Cruz MC, 2000, IFESS 2000, 436

10.1136/jnnp.53.8.681

Schneider A, 2004, Implantable flexible electrodes for functional electrical stimulation, Med Device Technol, 15, 16

ShimojoM SuzukiT NamikiA SaitoT KunimotoM MakinoR OgawaH IshikawaM MabuchiK(2003). Development of a system for experiencing tactile sensation from a robot hand by electrically stimulating sensory nerve fiber. Proceedings of the IEEE International Conference on Robotics and Automation pp1263–1270.

SinghJ PeckRA LoebGE(2001). Development of BIONs technology for functional electrical stimulation: hermetic packaging. Proceedings of the 23th Annual International Conference of IEEE Eng Med and Bio Soc.

10.1109/86.867869

Sinkjaer T, 2003, Biopotentials as command and feedback signals in functional electrical stimulation systems, Med Eng Phys, 12, 29, 10.1016/S1350-4533(02)00178-9

10.1109/86.808943

10.1109/86.867887

10.1097/00004691-199701000-00004

10.1016/0006-8993(77)90233-5

Stein RB, 1992, Neural Prostheses. Replacing Motor Function After Diseases or Disability

10.1016/S0022-5347(17)36526-6

Stieglitz T, 2004, Considerations on surface and structural biocompatibility as prerequisite for long‐term stability of neural prostheses, J Nanosci Nanotechnol, 4, 496, 10.1166/jnn.2004.075

Stieglitz T, 1997, A flexible, light‐weight multichannel sieve electrode with integrated cables for interfacing regenerating peripheral nerves, Sensors Actuators, 60, 240, 10.1016/S0924-4247(97)01494-5

10.1023/A:1009955222114

Stieglitz T, 2002, Flexible BIOMEMS with electrode arrangements on front and back side as key component in neural prostheses and biohybrid systems, Sensors Actuators B, 12, 1

StieglitzT HabererW KammerS SchanzeT(2003). A simple model to investigate the stability of flexible micromachined retina stimulators. Proceedings of the 8th Annual International Conference of the International Functional Electrical Stimulation Society pp69–73.

StieglitzT MeyerJU(1997).Microtechnical interfaces to neurons.Microsyst Technol Chem Life Scipp131–162.

10.1016/S0956-5663(02)00019-2

10.1515/BMT.2004.015

Strege DW, 1994, Chronic peripheral nerve pain treated with direct electrical nerve stimulation, J Hand Surg [Am], 19, 37, 10.1016/0363-5023(94)90092-2

10.1109/10.55681

10.1088/0960-1317/14/1/014

Tatic‐LucicS TaiY‐C WrightJA PineJ DenisonT(1993). Silicon‐micromachined neurochips for in vitro studies of cultured neural networks. Proceedings of the International Conference on Solid State Sensors and Actuators pp943–946.

10.1016/S0003-9993(99)90333-7

Taylor PN, 2002, Electrical stimulation of abdominal muscles for control of blood pressure and augmentation of cough in a C3/4 level tetraplegic, Spinal Cord, 40, 34, 10.1038/sj.sc.3101250

10.1152/jn.2000.84.1.591

10.1016/0014-4827(72)90481-8

10.1093/brain/110.6.1509

10.1016/S0003-9993(96)90133-1

Tyler DJ, 1994, Interfascicular electrical stimulation for selectively activating axons, IEEE–EMBS Mag, 13, 575

10.1109/86.559349

10.1109/TNSRE.2002.806840

10.1114/1.1569263

10.1109/86.681183

10.1152/physrev.1979.59.4.919

10.1002/nau.1930120511

10.1007/BF02442165

10.1109/10.237694

Vogt M, 1995, Plasma‐deposited passivation layers for moisture and water protection, Surface Coatings Technol, 74, 676, 10.1016/0257-8972(95)08268-9

10.1016/S0142-9612(00)00342-2

10.1080/10790268.1997.11719475

10.1001/archneur.60.10.1369

10.2106/00004623-198567050-00016

10.1139/y04-078

10.1109/TBME.2002.805487

Wells MR, 2001, A neuromuscular platform to extract electrophysiological signals from lesioned nerves: a technical note, J Rehabil Res Dev, 38, 385

Wilkinson DW, 1987, Topographical control of cell behaviour, Development, 99, 439, 10.1242/dev.99.3.439

10.1016/S0003-9993(99)90123-5

10.1109/10.855936

10.1109/10.243412

10.1016/S0165-0270(99)00176-4

10.1109/10.740885

Zajac FE, 1989, Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control, Crit Rev Biomed Eng, 17, 359

10.1109/86.481972

10.1615/CritRevBiomedEng.v30.i456.80

10.1016/S0142-9612(96)00112-3

10.1002/mus.10358