A conservative approach to retrieve a fractured abutment screw – Case report

Journal of Prosthodontic Research - Tập 60 - Trang 138-142 - 2016
Thiago de Almeida Prado Naves Carneiro1, Marcel Santana Prudente1, Roberto Sales e Pessoa2, Gustavo Mendonça3, Flávio Domingues das Neves1
1Department of Occlusion, Fixed Prostheses, and Dental Materials, School of Dentistry, Universidade Federal de Uberlândia, Uberlândia, Minas Gerais, Brazil
2BMe, Biomechanical Section, Katholieke Universiteit, Leuven, Belgium
3University of Michigan, School of Dentistry, Department of Biologic and Material Sciences, Division of Prosthodontics, Ann Arbor, MI, United States

Tài liệu tham khảo

Brånemark, 1977, Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period, Scand J Plast Reconstr Surg Suppl, 16, 1 Naert, 1992, A six-year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism, J Prosthet Dent, 67, 236, 10.1016/0022-3913(92)90461-I Quirynen, 1992, Fixture design and overload influence marginal bone loss and fixture success in the Branemark system, Clin Oral Implants Res, 3, 104, 10.1034/j.1600-0501.1992.030302.x Adell, 1981, A 15-year study of osseointegrated implants in the treatment of the edentulous jaw, Int J Oral Surg, 10, 387, 10.1016/S0300-9785(81)80077-4 Becker, 1995, Replacement of maxillary and mandibular molars with single endosseous implant restorations: a retrospective study, J Prosthet Dent, 74, 51, 10.1016/S0022-3913(05)80229-X Goodacre, 2003, Clinical complications with implants and implant prostheses, J Prosthet Dent, 90, 121, 10.1016/S0022-3913(03)00212-9 Haas, 1995, Branemark single tooth implants: a preliminary report of 76 implants, J Prosthet Dent, 73, 274, 10.1016/S0022-3913(05)80205-7 Jemt, 1996, Measuring fit at the implant prosthodontic interface, J Prosthet Dent, 75, 314, 10.1016/S0022-3913(96)90491-6 Sones, 1989, Complications with osseointegrated implants, J Prosthet Dent, 62, 581, 10.1016/0022-3913(89)90084-X Schwarz, 2000, Mechanical complications of dental implants, Clin Oral Implants Res, 11, 156, 10.1034/j.1600-0501.2000.011S1156.x Iamam, 2014, A technique for retrieving fractured implant screws, J Prosthet Dent, 111, 81, 10.1016/j.prosdent.2013.04.007 Camargos, 2012, Clinical outcomes of single dental implants with external connections: results after 2 to 13 years, Int J Oral Maxillofac Implants Mendonça, 2009, Management of fractured dental implants: a case report, Implant Dent, 18, 10, 10.1097/ID.0b013e318192cafe Eckert, 2000, Analysis of incidence and associated factors with fractured implants: a retrospective study, Int J Oral Maxillofac Implants, 15, 662 Balshi, 1996, An analysis and management of fractured implants: a clinical report, Int J Oral Maxillofac Implants, 11, 660 Weinberg, 1993, The biomechanics of force distribution in implant-supported prostheses, Int J Oral Maxillofac Implants, 8, 19 Simon, 2003, Single implant-supported molar and premolar crowns: a ten-year retrospective clinical report, J Prosthet Dent, 90, 517, 10.1016/j.prosdent.2003.08.025 Al Jabbari, 2008, Mechanical behavior and failure analysis of prosthetic retaining screws after long-term use in vivo. Part 3: Preload and tensile fracture load testing, J Prosthodont, 17, 192, 10.1111/j.1532-849X.2007.00290.x Binon, 1996, The effect of eliminating implant/abutment rotational misfit on screw joint stability, Int J Prosthodont, 9, 511 Att, 2006, Fracture resistance of single-tooth implant-supported all-ceramic restorations: an in vitro study, J Prosthet Dent, 95, 111, 10.1016/j.prosdent.2005.12.003 Khraisat, 2004, Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system, J Prosthet Dent, 91, 326, 10.1016/j.prosdent.2004.01.001 Byrne, 2006, Preloads generated with repeated tightening in three types of screws used in dental implant assemblies, J Prosthodont, 15, 164, 10.1111/j.1532-849X.2006.00096.x Park, 2010, Effects of abutment screw coating on implant preload, J Prosthodont, 19, 458, 10.1111/j.1532-849X.2010.00595.x