A comparison of the performance of voltammetric aptasensors for glycated haemoglobin on different carbon nanomaterials-modified screen printed electrodes

Materials Science and Engineering: C - Tập 101 - Trang 423-430 - 2019
Shimaa Eissa1, Abrar Yousef Almusharraf1, Mohammed Zourob1,2
1Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh 11533, Saudi Arabia
2King Faisal Specialist Hospital and Research Center, Zahrawi Street, Al Maather, Riyadh, 12713, Saudi Arabia

Tài liệu tham khảo

Farzin, 2018, J. Pharm. Biomed. Anal., 147, 185, 10.1016/j.jpba.2017.07.042 Chikkaveeraiah, 2012, ACS Nano, 6, 6546, 10.1021/nn3023969 Ramnani, 2016, Chemosphere, 143, 85, 10.1016/j.chemosphere.2015.04.063 Vanegas, 2016, Biosens. J., 5, 10.4172/2090-4967.1000137 Bunney, 2017, Curr. Res. Nutr. Food Sci. J., 5, 183, 10.12944/CRNFSJ.5.3.02 Zhang, 2009, Sensors, 9, 1033, 10.3390/s90201033 Holzinger, 2014, Front. Chem., 2, 10.3389/fchem.2014.00063 Shavanova, 2016, Sensors, 16, 223, 10.3390/s16020223 Wang, 2005, Analyst, 130, 421, 10.1039/b414248a Grieshaber, 2008, Sensors, 8, 1400, 10.3390/s80314000 Tudorache, 2007, Anal. Bioanal. Chem., 388, 565, 10.1007/s00216-007-1293-0 Renedo, 2007, Talanta, 73, 202, 10.1016/j.talanta.2007.03.050 Yang, 2010, Angew. Chem. Int. Ed., 49, 2114, 10.1002/anie.200903463 Zheng, 2013, Materials, 6, 1011, 10.3390/ma6031011 Eissa, 2018, Biosens. Bioelectron., 101, 282, 10.1016/j.bios.2017.10.015 Eatemadi, 2014, Nanoscale Res. Lett., 9, 393, 10.1186/1556-276X-9-393 Shojaeenezhad, 2017, J. Sci. Adv. Mater. Devices, 2, 470, 10.1016/j.jsamd.2017.09.003 Poh, 2012, Nanoscale, 4, 3515, 10.1039/c2nr30490b Wang, 2016, Biosens. Bioelectron., 79, 136, 10.1016/j.bios.2015.11.093 Qin, 2017, Food Control, 73, 726, 10.1016/j.foodcont.2016.09.023 Wang, 2011, Chem. Commun., 47, 7794, 10.1039/c1cc11373a Hernandez, 2012, Biosensors, 2, 10.3390/bios2010001 Zhao, 2011, Electrochem. Commun., 13, 31, 10.1016/j.elecom.2010.11.005 Porfireva, 2010, Electroanalysis, 22, 2187, 10.1002/elan.201000174 Song, 2009, Sensors Actuators B Chem., 140, 233, 10.1016/j.snb.2009.04.057 Liu, 2008, Clin. Biochem., 41, 576, 10.1016/j.clinbiochem.2008.01.013 Loh, 2014, Pathology, 46, 265, 10.1097/PAT.0000000000000087 Weykamp, 2013, Ann. Lab. Med., 33, 393, 10.3343/alm.2013.33.6.393 Chen, 2012, Anal. Chem., 84, 8635, 10.1021/ac301756d Tanaka, 2001, Biosens. Bioelectron., 16, 1089, 10.1016/S0956-5663(01)00187-7 Salek-Maghsoudi, 2018, Biosens. Bioelectron., 99, 122, 10.1016/j.bios.2017.07.047 Wang, 2015, Materials, 8, 1187, 10.3390/ma8031187 Zhou, 2014, Analyst, 139, 2627, 10.1039/c4an00132j Jarczewska, 2016, Anal. Methods, 8, 3861, 10.1039/C6AY00499G Almusharraf, 2018, Microchim. Acta, 185, 256, 10.1007/s00604-018-2789-3 Eissa, 2017, Sci. Rep., 7, 1016, 10.1038/s41598-017-01226-0