A case of progressive right ventricular failure with ventricular arrhythmia and aortic insufficiency after implantable left ventricular assist device implantation

Takahiro Jimba1, Masaru Hatano2, Takayuki Fujiwara1, Hiroshi Akazawa1, Masafumi Watanabe3, Koichiro Kinugawa4, Minoru Ono5, Issei Komuro1
1Department of Cardiovascular Medicine, Graduate School of Medicine and Faculty of Medicine, The University of Tokyo, Tokyo, Japan
2Department of Advanced Medical Center for Heart Failure, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
3Department of Cardiology, Pulmonology, and Nephrology, Yamagata University School of Medicine, Yamagata, Japan
4Second Department of Internal Medicine, University of Toyama, Toyama, Japan
5Department of Thoracic Surgery, Graduate School of Medicine and Faculty of Medicine, The University of Tokyo, Tokyo, Japan

Tài liệu tham khảo

Ali, 2020, Right ventricular failure post-implantation of left ventricular assist device: prevalence, pathophysiology, and predictors, ASAIO J, 66, 610, 10.1097/MAT.0000000000001088 Kormos, 2020, Updated definitions of adverse events for trials and registries of mechanical circulatory support: a consensus statement of the mechanical circulatory support academic research consortium, J Heart Lung Transplant, 39, 735, 10.1016/j.healun.2020.03.010 Slaughter, 2010, Clinical management of continuous-flow left ventricular assist devices in advanced heart failure, J Heart Lung Transplant, 29, S1, 10.1016/j.healun.2010.01.011 Imamura, 2014, Late-onset right ventricular failure in patients with preoperative small left ventricle after implantation of continuous flow left ventricular assist device, Circ J, 78, 625, 10.1253/circj.CJ-13-1201 Takeda, 2015, Late right heart failure during support with continuous-flow left ventricular assist devices adversely affects post-transplant outcome, J Heart Lung Transplant, 34, 667, 10.1016/j.healun.2014.10.005 Gopinathannair, 2019, Device therapy and arrhythmia management in left ventricular assist device recipients: a scientific statement from the American Heart Association, Circulation, 139, e967, 10.1161/CIR.0000000000000673 Cowger, 2015, Comprehensive review and suggested strategies for the detection and management of aortic insufficiency in patients with a continuous-flow left ventricular assist device, J Heart Lung Transplant, 34, 149, 10.1016/j.healun.2014.09.045 Marasco, 2020, International experience using a durable, centrifugal-flow ventricular assist device for biventricular support, J Heart Lung Transplant, 39, 1372, 10.1016/j.healun.2020.08.006 Hatano, 2022, Late-onset right ventricular failure after continuous-flow left ventricular assist device implantation: case presentation and review of the literature, J Cardiol, 80, 110, 10.1016/j.jjcc.2021.12.009