A biosensor based on magnetoresistance technology

Biosensors and Bioelectronics - Tập 13 Số 7-8 - Trang 731-739 - 1998
David R. Baselt1, Gil U. Lee2, Mohan Natesan3, Steven Metzger3, Paul E. Sheehan2, Richard J. Colton2
1Naval Research Laboratory, Washington, DC 20375-5342, USA
2Code 6177, Naval Research Laboratory, Washington DC 20375-5342, USA
3Geo-Centers, Inc., 4601 Presidents Drive, Suite 210, Lanham, MD 20706, USA

Tóm tắt

Từ khóa


Tài liệu tham khảo

Allen, 1997, Detection of antigen-antibody binding events with the atomic force microscope, Biochemistry, 36, 7457, 10.1021/bi962531z

Baibich, 1988, Giant magnetoresistance of (001)Fe/(001)Cr magnetic superlattices, Phys. Rev. Lett., 61, 2472, 10.1103/PhysRevLett.61.2472

Baselt, 1997, A High-Sensitivity Micromachined Biosensor, Proc. IEEE, 85, 672, 10.1109/5.573755

Chang, 1996, Influence of direction and type of applied force on the detachment of macromolecularly-bound particles from surfaces, Langmuir, 12, 2271, 10.1021/la950690y

Chrisey, 1996, Covalent attachment of synthetic DNA to self-assembled monolayer films, Nucleic Acids Res., 24, 3031, 10.1093/nar/24.15.3031

Cussler, E.L., 1994. Mass Transfer in Fluid Systems. Cambridge Press, New York.

Dammer, 1996, Specific antigen/antibody interactions measured by force microscopy, Biophys. J., 70, 2411, 10.1016/S0006-3495(96)79814-4

Daughton, 1992, Magnetoresistive memory technology, Thin Solid Films, 216, 162, 10.1016/0040-6090(92)90888-I

Dieny, 1991, Giant magnetoresistance in soft ferromagnetic multilayers, Phys. Rev. B, 43, 1297, 10.1103/PhysRevB.43.1297

Evans, 1995, Sensitive force technique to probe molecular adhesion and structural linkages at biological interfaces, Biophys. J., 68, 2580, 10.1016/S0006-3495(95)80441-8

Florin, 1995, Sensing specific molecular interactions with the atomic force microscope, Biosens. Bioelectron., 10, 895, 10.1016/0956-5663(95)99227-C

Hinterdorfer, 1996, Detection and localization of individual antibody-antigen recognition events by atomic force microscopy, Proc. Natl. Acad. Sci. USA, 93, 3477, 10.1073/pnas.93.8.3477

Hoh, 1994, Measuring the streptavidin-biotin binding force, Proc. Micro. Soc. Am., 52, 1054

Kötitz, 1997, SQUID based remanence measurements for immunoassays, IEEE Trans. Appl. Supercond., 7, 3678, 10.1109/77.622216

Kriz, 1996, Magnetic permeability measurements in bioanalysis and biosensors, Anal. Chem., 68, 1966, 10.1021/ac951227t

Kriz, K., Gehrke, J., Kriz, D., 1998. Advances toward magneto immunoassays. In this issue of Biosens. Bioelectron.

Kuo, 1993, Relationship between receptor/ligand binding affinity and adhesion strength, Biophys. J., 65, 2191, 10.1016/S0006-3495(93)81277-3

Lee, 1994, Direct measurement of the forces between complementary strands of DNA, Science, 266, 771, 10.1126/science.7973628

Lee, 1994, Sensing discrete streptavidin-biotin interactions with atomic force microscopy, Langmuir, 10, 354, 10.1021/la00014a003

Long, 1993, Detection of Francisella tularensis in blood by polymerase chain reaction, J. Clin. Microbiol., 31, 152, 10.1128/JCM.31.1.152-154.1993

Ludwig, 1997, Atomic force microscope imaging contrast based on molecular recognition, Biophys. J., 72, 445, 10.1016/S0006-3495(97)78685-5

O'Donnell-Maloney, 1996, Microfabrication and array technologies for DNA sequencing and diagnostics, Genet. Anal., 13, 151, 10.1016/S1050-3862(96)00166-0

Pierres, 1996, Measuring bonds between surface-associated molecules, J. Immunol. Methods, 196, 105, 10.1016/0022-1759(96)00103-2

Stuart, 1995, Effects of discrete protein-surface interactions in scanning force microscopy adhesion force measurements, Langmuir, 11, 1368, 10.1021/la00004a051

Wong, 1997, Direct measurement of a tethered ligand-receptor interaction potential, Science, 275, 820, 10.1126/science.275.5301.820