A Finite Element Model of the Human Knee Joint for the Study of Tibio-Femoral Contact

Journal of Biomechanical Engineering - Tập 124 Số 3 - Trang 273-280 - 2002
Tammy L. Haut Donahue1, Maury L. Hull2, Mark M. Rashid3, Christopher R. Jacobs4
1Department of Mechanical Engineering, Michigan Technological University, Houghton 49931, USA.
2Department of Mechanical Engineering, and Biomedical Engineering Graduate Group, University of California at Davis, Davis, CA 95616
3Department of Civil Engineering, University of California at Davis, Davis, CA 95616
4Musculoskeletal Research Laboratory, Penn State University, Hershey, PA 17033

Tóm tắt

As a step towards developing a finite element model of the knee that can be used to study how the variables associated with a meniscal replacement affect tibio-femoral contact, the goals of this study were 1) to develop a geometrically accurate three-dimensional solid model of the knee joint with special attention given to the menisci and articular cartilage, 2) to determine to what extent bony deformations affect contact behavior, and 3) to determine whether constraining rotations other than flexion/extension affects the contact behavior of the joint during compressive loading. The model included both the cortical and trabecular bone of the femur and tibia, articular cartilage of the femoral condyles and tibial plateau, both the medial and lateral menisci with their horn attachments, the transverse ligament, the anterior cruciate ligament, and the medial collateral ligament. The solid models for the menisci and articular cartilage were created from surface scans provided by a noncontacting, laser-based, three-dimensional coordinate digitizing system with an root mean squared error (RMSE) of less than 8 microns. Solid models of both the tibia and femur were created from CT images, except for the most proximal surface of the tibia and most distal surface of the femur which were created with the three-dimensional coordinate digitizing system. The constitutive relation of the menisci treated the tissue as transversely isotropic and linearly elastic. Under the application of an 800 N compressive load at 0 degrees of flexion, six contact variables in each compartment (i.e., medial and lateral) were computed including maximum pressure, mean pressure, contact area, total contact force, and coordinates of the center of pressure. Convergence of the finite element solution was studied using three mesh sizes ranging from an average element size of 5 mm by 5 mm to 1 mm by 1 mm. The solution was considered converged for an average element size of 2 mm by 2 mm. Using this mesh size, finite element solutions for rigid versus deformable bones indicated that none of the contact variables changed by more than 2% when the femur and tibia were treated as rigid. However, differences in contact variables as large as 19% occurred when rotations other than flexion/extension were constrained. The largest difference was in the maximum pressure. Among the principal conclusions of the study are that accurate finite element solutions of tibio-femoral contact behavior can be obtained by treating the bones as rigid. However, unrealistic constraints on rotations other than flexion/extension can result in relatively large errors in contact variables.

Từ khóa


Tài liệu tham khảo

Newman, A. P., Daniels, A. U., and Burks, R. T., 1993, “Principles and Decision Making in Meniscal Surgery,” Arthroscopy, 9, pp. 33–51.

Siegel, M. G., and Roberts, C. S., 1993, “Meniscal Allografts,” Clin. Sports Med., 12, pp. 59–80.

Rangger, C., Klestil, T., Gloetzer, W., Kemmler, G., and Benedetto, L. P., 1995, “Osteoarthritis After Arthroscopic Partial Meniscectomy,” Am. J. Sports Med., 23, pp. 240–244.

Fauno, P., and Nielson, A. B., 1992, “Arthroscopic Partial Meniscectomy: A Long Term Follow-Up,” Arthroscopy, 8, pp. 345–349.

Bolano, L. E., and Grana, W. A., 1993, “Isolated Arthroscopic Partial Meniscectomy: Functional Radiographic Evaluation at Five Years,” Am. J. Sports Med., 21, pp. 432–437.

Aspden, R. M. , 1985, “A Model for the Function and Failure of the Meniscus,” Eng. Med., 14, pp. 119–122.

Hefzy, M. S., Grood, E. S., and Zoghi, M., 1987, “An Axisymmetric Finite Element Model of the Meniscus,” in 1987 Advances in Bioengineering, American Society of Mechanical Engineers, New York, pp. 51–52.

Schreppers, G. J. M. A., Sauren, A. A. H. J., and Huson, A., 1990, “A Numerical Model of the Load Transmission in the Tibio-Femoral Contact Area,” Journal of Engineering in Medicine, 204, pp. 53–59.

Zhang, H., Totterman, S., Perucchio, R., and Lerner, A. L., 1999, “Magnetic Resonance Image Based 3D Poroelastic Finite Element Model of Tibio-Menisco-Femoral Contact,” in 23rd Proceedings of the American Society of Biomechanics, Pittsburgh, PA, pp. 198–199.

Perie, D., and Hobatho, M. C., 1998, “In Vivo Determination of Contact Areas and Pressure of the Femorotibial Joint Using Non-Linear Finite Element Analysis,” Clin. Biomech., 13, pp. 394–402.

Bendjaballah, M. Z., Shirazi-Adl, A., and Zukor, D. J., 1995, “Biomechanics of the Human Knee Joint in Compression: Reconstruction, Mesh Generation and Finite Element Analysis,” The Knee, 2, pp. 69–79.

Froimson, M. I., Ateshian, G. A., Soslowsky, L. J., Kelly, M. A., and Mow, V. C., 1989, “Quantification of the Surfaces at the Patellofemoral Articulation,” Proc. Inst. Mech. Eng. [H], 5, pp. 73–78.

Li, G., and Loopez, O., 1999, “Reliability of a 3D Finite Element Model Constructed Using Magnetic Resonance Images of a Knee for Joint Contact Stress Analysis,” in 23rd Proceedings of the American Society of Biomechanics, Pittsburgh, PA, pp. 196–197.

Andriacchi, T. P., Mikosz, R. P., Hampton, S. J., and Galante, J. O., 1983, “Model Studies of the Stiffness Characteristics of the Human Knee Joint,” J. Biomech., 16, pp. 23–29.

Bach, J. M., and Hull, M. L., 1995, “A New Load Application System for In Vitro Study of Ligamentous Injuries to the Human Knee Joint,” J. Biomech. Eng., 117, pp. 373–382.

Berns, G. S., Hull, M. L., and Patterson, H. A., 1990, “Implementation of a Five Degree of Freedom Automated System to Determine Knee Flexibility in Vitro,” J. Biomech. Eng., 112, pp. 392–400.

Haut, T. L., Hull, M. L., and Howell, S. M., 1997, “A High Accuracy Three-Dimensional Coordinate Digitizing System for Reconstructing the Geometry of Diarthrodial Joints,” J. Biomech., 31, pp. 571–577.

Ateshian, G. A., Soslowsky, L. J., and Mow, V. C., 1991, “Quantitation of Articular Surface Topography and Cartilage Thickness in Knee Joints Using Stereophotogrammetry,” J. Biomech., 24, pp. 761–776.

Ashman, R. B., Cowin, S. C., Van Bruskirk, W. C., and Rice, J. C., 1984, “A Continuous Wave Technique for the Measurement of the Elastic Properties of Bone,” J. Biomech., 17, pp. 349–361.

Lakes, R. S., and Katz, J. L., 1979, “Viscoelastic Properties of Wet Cortical Bone. III. A Non-linear Constitutive Equation,” J. Biomech., 12, pp. 689–698.

Cowin, S. C., 1989, “The Mechanical Properties of Cortical Bone Tissue,” in Bone Mechanics, S. C. Cowins, ed., CRC Press, Boca Raton, FL, pp. 98–127.

Cowin S. C., 1989, “The Mechanical Properties of Cancellous Bone,” in Bone Mechanics, S. C. Cowins, eds., CRC Press, Boca Raton, FL, pp. 129–157.

Knets, I., and Malmeister, A., 1977, “Deformability and Strength of Human Compact Bone Tissue,” Mechanics of Biological Solids, Bulgarian Academy of Sciences, pp. 133.

Kuhn, J. L., Goldstein, S. A., Ciarelli, M. J., and Matthews, L. S., 1989, “The Limitations of Canine Trabecular Bone as a Model for Human: A Biomechanical Study,” J. Biomech., 22, pp. 95–107.

Armstrong, C. G., Lai, W. M., and Mow, V. C., 1984, “An Analysis of the Unconfined Compression of Articular Cartilage,” J. Biomed. Eng., 106, pp. 165–173.

Eberhardt, A. W., Keer, L. M., Lewis, J. L., and Vithoontien, V., 1990, “An Analytical Model of Joint Contact,” J. Biomech. Eng., 112, pp. 407–413.

Shepard, D. E. T., and Seedhom, B. B., 1999, “The ‘Instantaneous’ Compressive Modulus of Human Articular Cartilage in Joints of the Lower Limb,” Rheumatology, 38, pp. 124–132.

Wismans, J., Veldpaus, F., Janssen, J., Huson, A., and Struben, P., 1980, “A Three-Dimensional Mathematical Model of the Knee Joint,” J. Biomech., 13, pp. 677–685.

Pandy, M. G., Sasaki, K., and Kim, S., 1997, “A Three-Dimensional Musculoskeletal Model of the Human Knee Joint. Part I: Theoretical Construction,” Computer Methods in Biomedical Engineering, 1, pp. 87–108.

Li, G., Gil, J., Kanamori, A., and Woo, S. L., 1999, “A Validated Three-Dimensional Computational Model of a Human Knee Joint,” J. Biomech. Eng., 121, pp. 657–662.

Blankevoort, L., Kuiper, J. H., Huiskes, R., and Grootenboer, H. J., 1991, “Articular Contact in a Three-Dimensional Model of the Knee,” J. Biomech., 24, pp. 1019–1031.

Butler, D. L., Kay, M. D., and Stouffer, D. C., 1986, “Comparison of Material Properties in Fascicle-Bone Units from Human Patellar Tendon and Knee Ligaments,” J. Biomech., 19, pp. 425–432.

Tissakht, M., and Ahmed, A. M., 1995, “Tensile Stress-Strain Characteristics of the Human Meniscal Material,” J. Biomech., 28, pp. 411–422.

Skaggs, D. L., Warden, W. H., and Mow, V. C., 1994, “Radial Tie Fibers Influence the Tensile Properties of the Bovine Medial Meniscus,” J. Orthop. Res., 12, pp. 176–185.

Whipple, R., Wirth, C. R., and Mow, V. C., 1984, “Mechanical Properties of the Meniscus,” in 1984 Advances in Bioengineering, American Society of Mechanical Engineers, New York, pp. 32–33.

Fithian, D. C., Schmidt, M. B., Ratcliffe, A., and Mow, V. C., 1989, “Human Meniscus Tensile Properties: Regional Variation and Biochemical Correlation,” in Transactions of the Orthopedic Research Society, 35, pp. 205.

Noyes, F. R., and Grood, E. S., 1976, “The Strength of the Anterior Cruciate Ligament in Humans and Rhesus Monkeys,” J. Bone Jt. Surg., Am. Vol., 58, pp. 1074–1082.

Merz, B., Niederer, P., Muller, R., and Ruegsegger, P., 1996, “Automated Finite Element Analysis of Excised Human Femora Based on Precision-QCT,” J. Biomech. Eng., 118, pp. 387–390.

Viceconti, M., Bellingeri, L., Cristofolini, L., and Toni, A., 1998, “A Comparative Study on Different Methods of Automatic Mesh Generation of Human Femurs,” Med. Eng. Phys., 20, pp. 1–10.

Allen, P. R., Denham, R. A., and Swan, A. V., 1984, “Late Degenerative Changes After Meniscectomy. Factors Affecting the Knee after Operation,” J. Bone Jt. Surg. Br. Vol. 66, pp. 666–671.

Howell, D. S., Treadwell, B. B., and Trippel, S. B., 1992, “Etiopathogenesis of Osteoarthritis,” in Osteoarthritis, Diagnosis and Medical/Surgical Management, R. W. Moskowitz, Howell, D. S., Goldberg, V. M., Mankin, H. J., eds., WB Saunders, Philadelphia, PA.

Donzelli, P. S., Spilker, R. L., Ateshian, G. A., and Mow, V. C., 1999, “Contact Analysis of Biphasic Transversely Isotropic Cartilage Layers and Correlations with Tissue Failure,” J. Biomech., 32, pp. 1037–1047.

Garcia, J. J., Altiero, N. J., and Haut, R. C., 1998, “An Approach for the Stress Analysis of Transversely Isotropic Biphasic Cartilage Under Impact Load,” J. Biomech. Eng., 120, pp. 608–613.

Ahmed, A. M., and Burke, D. L., 1983, “In-vitro Measurement of Static Pressure Distribution in Synovial Joints-Part I: Tibial Surface of the Knee,” J. Biomech. Eng., 105, pp. 216–225.

Alhalki, M. M., Howell, S. M., and Hull, M. L., 1999, “How Three Methods for Fixing a Medial Meniscal Autograft Affect Tibial Contact Mechanics,” Am. J. Sports Med., 27, pp. 320–328.

Fukubayashi, T., and Kurosawa, H., 1980, “The Contact Area and Pressure Distribution Pattern of the Knee. A Study of Normal and Osteoarthritic Knee Joints,” Acta Orthop. Scand., 51, pp. 871–879.

Huang, A. Z., 2000, “Cross-sectional Parameters of Lateral Meniscal Allografts that Determine the Differences in Tibial Contact Mechanics from the Intact Meniscus in Cadaveric Knees,” MS Thesis in Biomedical Engineering, University of California at Davis, Davis, CA.

Paletta, G. A., Manning, T., Snell, E., Parker, R., and Bergfeld, J., 1997, “The Effect of Allograft Meniscal Replacement on Intraarticular Contact Area and Pressures in the Human Knee,” Am. J. Sports Med., 25, pp. 692–698.

Sekaran, V., Hull, M. L., and Howell, S. M., 2002, “Non-anatomic Location of the Posterior Horn of the Medial Meniscal Autograft Implanted in a Cadaveric Knee Adversely Affects the Pressure Distribution on the Tibial Plateau,” Am. J. Sports Med., 30, pp. 74–82.

Chen, M. I., Branch, T. P., and Hutton, W. C., 1996, “Is It Important to Secure the Horns During Lateral Meniscal Transplantation? A Cadaveric Study,” Arthroscopy, 12, pp. 174–181.

Kadaba, M. P., Ramakrishnan, H. K., and Wootten, M. E., 1990, “Measurement of Lower Extremity Kinematics During Level Walking,” J. Orthop. Res., 8, pp. 383–392.

Lafortune, M. A., Cavanagh, P. R., Sommer, H. J., and Kalenak, A., 1992, “Three-Dimensional Kinematics of the Human Knee During Walking,” J. Biomech., 25, pp. 347–357.

Chao, E. Y., Laughman, R. K., Schneider, E., and Stauffer, R. N., 1983, “Normative Data of Knee Joint Motion and Ground Reaction Forces in Adult Level Walking,” J. Biomech., 16, pp. 219–233.