A Compilation of New and Published Major and Trace Element Data for NIST SRM 610 and NIST SRM 612 Glass Reference Materials

Wiley - Tập 21 Số 1 - Trang 115-144 - 1997
Nicholas J.G. Pearce1, William H. Perkins1, John A. Westgate2, Michael P. Gorton2, Simon E. Jackson3, C. R. Neal4, Simon Chenery5
1Institute of Earth Studies, University of Wales, Aberystwyth SY23 3DB, Wales, U.K.
2University of Toronto
3Department of Earth Sciences, Memorial University of Newfoundland, St. Johns, Newfoundland, A1B 3X5, Canada
4University of Notre Dame.
5British Geological Survey#TAB#

Tóm tắt

Microanalytical trace element techniques (such as ion probe or laser ablation ICP‐MS) are hampered by a lack of well characterized, homogeneous standards. Two silicate glass reference materials produced by National Institute of Standards and Technology (NIST), NIST SRM 610 and NIST SRM 612, have been shown to be homogeneous and are spiked with up to sixty one trace elements at nominal concentrations of 500 μg g‐1 and 50 μg g‐1 respectively. These samples (supplied as 3 mm wafers) are equivalent to NIST SRM 611 and NIST SRM 613 respectively (which are supplied as 1 mm wafers) and are becoming more widely used as potential microanalytical reference materials. NIST however, only certifies up to eight elements in these glasses. Here we have compiled concentration data from approximately sixty published works for both glasses, and have produced new analyses from our laboratories. Compilations are presented for the matrix composition of these glasses and for fifty eight trace elements. The trace element data includes all available new and published data, and summaries present the overall average and standard deviation, the range, median, geometric mean and a preferred average (which excludes all data outside ± one standard deviation of the overall average). For the elements which have been certified, there is a good agreement between the compiled averages and the NIST data. This compilation is designed to provide useful new working values for these reference materials.

Từ khóa


Tài liệu tham khảo

10.1111/j.1751-908X.1979.tb00250.x

10.1021/ac60328a005

10.1111/j.1751-908X.1984.tb00405.x

10.1016/0009-2541(94)90104-X

10.1016/0584-8547(90)80049-O

10.1016/0584-8547(90)80050-S

10.1016/0168-583X(88)90040-7

10.1007/BF00424686

10.1016/0020-7381(76)80073-3

Bonham R.W., 1989, Coupling of a spark‐source mass spectrograph and an Nd:YAG laser, Spectroscopy International, 1, 42

10.1007/BF00476401

10.1021/ac60311a028

CarpenterB.S.andPilloneLJ.(1986).The use of delayed nuclear track counting for determining bismuth. In Proceedings of the Seventh Modern Trends in Activation Analysis. (Copenhagen) 473–478.

10.1016/0168-583X(93)95718-K

10.1039/ja9930800299

10.1007/BF02261210

10.1111/j.1751-908X.1982.tb00337.x

DenoyerE.R.(1990)Laser sampling ICP‐MS of high purity quartz and glasses. Perkin‐Elmer Laser Application Report No LAR‐5.

10.1021/ac00008a001

10.1016/0009-2541(93)90029-I

10.1021/ac00292a066

10.1007/BF02132373

Freidli C., 1988, Studies in heavy ion activation analysis. X. Trace determination possibilities with 11B ion bombardment, Journal of Radioanalytical and Nuclear Chemistry - Articles, 120, 253

Freidli C., 1988, Studies in heavy ion activation analysis. XI. Trace determination possibilities with 15 N ion bombardment, Journal of Radioanalytical and Nuclear Chemistry - Articles, 122, 115

10.1111/j.1751-908X.1993.tb00122.x

10.1021/ac50008a021

GladneyE.S. BurnsC.E. PerrinD.R. RobinsonR.D.andKnabD.(1984)Quality assurance for environmental analytical chemistry: 1982. Los Alamos National Laboratory Report LA‐9950‐MS.

10.1111/j.1751-908X.1984.tb00410.x

10.1111/j.1751-908X.1985.tb00434.x

GladneyE.S. O'MalleyB.T. RoelandtsI.andGillsT.E.(1987)Compilation of elemental concentration data for NBS clinical biological geological and environmental standard reference materials. National Bureau of Standards Special Publication 260‐111 547pp.

10.1111/j.1751-908X.1995.tb00152.x

10.1039/an9901500159

10.1007/BF00371062

10.1039/an9952001373

HaneyM.A.(1977)Comparison of window glasses by isotope dilution spark source mass spectrometry.Journal of Forensic Sciences .

10.1021/ac50019a006

10.1039/an9840900113

10.1021/ac60307a033

10.1016/0009-2541(90)90136-U

10.1039/an9952001315

10.1111/j.1751-908X.1995.tb00149.x

10.1016/0009-2541(94)90128-7

10.1007/BF01245099

Ingamells CO., 1986, Applied Geochemical Analysis, 733

Jackson S.E., 1992, The application of laser ablation microprobe inductively coupled plasma‐mass spectrometry (LAM‐ICP‐MS) to in situ trace element determinations in minerals, Canadian Mineralogist, 30, 1049

JeffriesT.E.(1996)Investigations of mineral analysis by laser ablation inductively coupled plasma‐mass spectrometry. Unpublished Ph.D. thesis University of Wales Aberystwyth.

10.1039/ac9963300035

10.1016/0009-2541(90)90145-W

Johnson W.M., 1981, Rock and Mineral Analysis, 489

Joyce J.R., 1984, Low energy proton activation with X‐ray counting, Journal of Trace and Microprobe Techniques, 2, 53

10.1016/S0003-2670(01)84410-X

10.1007/BF02513934

Kobayashi K., 1986, Determination of trace elements in electronic materials by NAA, Bunseki Kagu, 35, 734

10.1007/BF02037147

Lass B.D., 1982, Heavy ion activation analysis, Journal of Radioanalytical Chemistry, 70, 251

10.1007/BF00371291

10.1016/0009-2541(90)90143-U

10.1016/0584-8547(90)80136-7

10.1021/ac60326a012

10.1021/ac60364a027

10.1021/ac60366a027

10.1016/0016-7037(88)90083-X

10.1016/0584-8547(93)80006-G

10.1021/ac60336a014

10.1016/S0003-2670(01)85278-8

10.1016/1040-6182(95)00087-9

10.1007/BF02162580

10.1007/978-1-4615-2053-5_7

Pouchou J.L, 1985, Microbeam analysis ‐1985, 104

10.1007/PL00012714

10.1016/0168-583X(95)00267-7

10.1016/0168-583X(87)90310-7

Sankar Das M., 1979, Geometric means as probable values for compiled data on geochemical samples, Geostandards Newsletter, 2, 199

Sheibley D.W., 1973, Trace elements in fuel, 98

10.1111/j.1751-908X.1992.tb00483.x

10.1016/0168-583X(93)95713-F

Thompson M., 1983, A handbook of inductively coupled plasma spectro‐metry, 273

10.1007/BF02169835

10.1016/0020-708X(80)90027-7

10.1016/0016-7037(92)90088-Z

10.1016/0883-2927(94)90042-6

10.1016/0029-554X(76)90013-6

10.1016/0009-2541(85)90047-6