Efficacy and cardiovascular tolerability of extended dialysis in critically ill patients: a randomized controlled study
Tóm tắt
Từ khóa
Tài liệu tham khảo
Silvester, 1998, Outcome studies of continuous renal replacement therapy in the intensive care unit, Kidney Int Suppl, 66, S138
Paganini, 2001, Severity scores and outcomes with acute renal failure in the ICU setting, Contrib Nephrol, 132, 181, 10.1159/000060091
Mehta, 2002, Refining predictive models in critically ill patients with acute renal failure, J Am Soc Nephrol, 13, 1350, 10.1097/01.ASN.0000014692.19351.52
Vanholder, 2001, What is the renal replacement method of first choice for intensive care patients?, J Am Soc Nephrol, 12, S40, 10.1681/ASN.V12suppl_1s40
Ronco, 2000, Effect of different doses in continuous veno-venous hemofiltration on outcomes of acute renal failure, Lancet, 356, 26, 10.1016/S0140-6736(00)02430-2
Kumar, 2002, Daily dialysis in the intensive care unit, Int J Artif Organs, 25, 1031, 10.1177/039139880202501101
Manns, 2003, Cost of acute renal failure requiring dialysis in the intensive care unit, Crit Care Med, 31, 449, 10.1097/01.CCM.0000045182.90302.B3
Mehta, 2001, A randomized clinical trial of continuous versus intermittent dialysis for acute renal failure, Kidney Int, 60, 1154, 10.1046/j.1523-1755.2001.0600031154.x
Tonelli, 2002, Acute renal failure in the intensive care unit, Am J Kidney Dis, 40, 875, 10.1053/ajkd.2002.36318
Marshall, 2001, Sustained low-efficiency dialysis for critically ill patients requiring renal replacement therapy, Kidney Int, 60, 777, 10.1046/j.1523-1755.2001.060002777.x
van Bommel, 1995, Use of APACHE II classification to evaluate outcome and response to therapy in acute renal failure patients in a surgical intensive care unit, Ren Fail, 17, 731, 10.3109/08860229509037641
Kleophas, 1998, Long-term experience with an ultrapure individual dialysis fluid with a batch type machine, Nephrol Dial Transplant, 13, 3118, 10.1093/ndt/13.12.3118
Dhondt, 2003, Studies on dialysate mixing in the Genius single-pass batch system for hemodialysis therapy, Kidney Int, 63, 1540, 10.1046/j.1523-1755.2003.00862.x
Faltlhauser, 1996, Accuracy of less invasive device for rapid beat-to-beat continuous cardiac output monitoring, Intensive Care Med, 22, S364
Venkataraman, 2002, Dosing patterns for continuous renal replacement therapy at a large academic medical center in the US, J Crit Care, 17, 246, 10.1053/jcrc.2002.36757
Kaufman, 1998, Effects of controlled blood cooling on hemodynamic stability and urea kinetics during high-efficiency hemodialysis, J Am Soc Nephrol, 9, 877, 10.1681/ASN.V95877
Yagi, 1998, Cooling effect of continuous renal replacement therapy in critically ill patients, Am J Kidney Dis, 32, 1023, 10.1016/S0272-6386(98)70078-2
Cole, 2001, High-volume haemofiltration in human septic shock, Intensive Care Med, 27, 978, 10.1007/s001340100963
Kanagasundaram, 2003, A preliminary survey of bacterial contamination of the dialysate circuit in continuous veno-venous hemodialysis, Clin Nephrol, 59, 47, 10.5414/CNP59047
Barenbrock, 2000, Effects of bicarbonate- and lactate-buffered replacement fluids on cardiovascular outcome in CVVH patients, Kidney Int, 58, 1751, 10.1046/j.1523-1755.2000.00336.x
Mehta, 2003, In critically ill patients with acute renal failure, outcomes, not dollars, should drive modality choice, Crit Care Med, 31, 644, 10.1097/01.CCM.0000045183.74244.14