Attenuation correction for a combined 3D PET/CT scanner

Medical Physics - Tập 25 Số 10 - Trang 2046-2053 - 1998
Paul E. Kinahan1, David W. Townsend, Thomas Beyer, Donald Sashin
1Department of Radiology, University of Pittsburgh, Pennsylvania 15213, USA. [email protected]

Tóm tắt

In this work we demonstrate the proof of principle of CT‐based attenuation correction of 3D positron emission tomography (PET) data by using scans of bone and soft tissue equivalent phantoms and scans of humans. This method of attenuation correction is intended for use in a single scanner that combines volume‐imaging (3D) PET with x‐ray computed tomography (CT) for the purpose of providing accurately registered anatomical localization of structures seen in the PET image. The goal of this work is to determine if we can perform attenuation correction of the PET emission data using accurately aligned CT attenuation information. We discuss possible methods of calculating the PET attenuation map at 511 keV based on CT transmission information acquired from 40 keV through 140 keV. Data were acquired on separate CT and PET scanners and were aligned using standard image registration procedures. Results are presented on three of the attenuation calculation methods: segmentation, scaling, and our proposed hybrid segmentation/scaling method. The results are compared with those using the standard 3D PET attenuation correction method as a gold standard. We demonstrate the efficacy of our proposed hybrid method for converting the CT attenuation map from an effective CT photon energy of 70 keV to the PET photon energy of 511 keV. We conclude that using CT information is a feasible way to obtain attenuation correction factors for 3D PET.

Từ khóa


Tài liệu tham khảo

Strauss L. G., 1991, The applications of PET in clinical oncology, J. Nucl. Med., 32, 623

10.1007/BF01249629

10.1007/BF01728302

Charles C. Watson Danny F. Newport and Mike E. Casey “A single scatter simulation technique for scatter correction in three‐dimensional PET ” inThree‐Dimensional Image Reconstruction in Radiology and Nuclear Medicine edited by Pierre Grangeat and Jean‐Louis Amans (Kluwer Dordrect The Netherlands 1996) Vol. 4 pp. 255–268.

10.1118/1.597394

Richard Leahy and X. Yan “Incorporation of anatomical MR data for improved functional imaging with PET ” conference record of the Information Processing in Medical Imaging: 12th International Conference Wye U.K. 1991.

10.1109/42.108584

10.1088/0031-9155/21/5/002

J. H. Hubbell Report No. NSRDS‐NBS 29 1969.

Hasegawa B. H., 1993, Object specific attenuation correction of SPECT with correlated dual‐energy x‐ray CT, IEEE Trans. Nucl. Sci., 40, 1242, 10.1109/TNS.1993.8526573

10.1109/23.34585

10.1109/23.340649

10.1097/00004728-197903060-00006

T. Beyer P. E. Kinahan D. W. Townsend et al. “The use of x‐ray CT for attenuation correction of PET data ” conference record of the IEEE Nuclear Science Symposium and Medical Imaging Conference Norfolk VA 1994.

Karp J. S., 1991, Performance standards in positron emission tomography, J. Nucl. Med., 32, 2342

10.1109/23.531891

International Commission on Radiation Units and Measurements Report No. 44 1989.

S. Grootoonk T. J. Spinks T. Jones et al. “Correction for scatter using a dual energy window technique with a tomograph operating without septa ” conference record of the IEEE Nuclear Science Symposium and Medical Imaging Conference Orlando FL 1992.

10.1097/00004728-199207000-00024

10.1088/0031-9155/39/3/009

10.1109/23.485974