A NURBS-based technique for subject-specific construction of knee bone geometry

Computer Methods and Programs in Biomedicine - Tập 92 - Trang 20-34 - 2008
Anthony G. Au1, Darren Palathinkal1, Adrian B. Liggins2, V. James Raso2, Jason Carey1, Robert G. Lambert3, A. Amirfazli1
1Department of Mechanical Engineering, University of Alberta, Canada
2Capital Health Authority, Glenrose Rehabilitation Hospital Site, Canada
3Department of Radiology and Diagnostic Imaging, University of Alberta, Canada

Tài liệu tham khảo

Dawson, 1992, Consequences of an interference fit on the fixation of porous-coated tibial components in total knee replacement, Journal of Bone and Joint Surgery [Am], 74-A, 233, 10.2106/00004623-199274020-00009 Rakotomanana, 1992, A finite element model for evaluation of tibial prosthesis-bone interface in total knee replacement, Journal of Biomechanics, 25, 1413, 10.1016/0021-9290(92)90055-6 Tissakht, 1996, Calculated stress-shielding in the distal femur after total knee replacement corresponds to the reported location of bone loss, Journal of Orthopaedic Research, 14, 778, 10.1002/jor.1100140515 Taylor, 1998, Finite element analysis of the implanted proximal tibia: a relationship between the initial cancellous bone stresses and implant migration, Journal of Biomechanics, 31, 303, 10.1016/S0021-9290(98)00022-0 Van Loon, 1999, Femoral bone loss in total knee arthroplasty: a review, Acta Orthopaedica Belgica, 65, 154 Eibeck, 1979, Finite element stress analysis of hinged tibial component total joint replacements, 298 Beaupre, 1986, Epiphyseal-based designs for tibial plateau components. II: Stress analysis in the sagittal plane, Journal of Biomechanics, 19, 663, 10.1016/0021-9290(86)90171-5 Lewis, 1998, Effect of material property representation on stresses in endoprostheses, Bio-Medical Materials and Engineering, 8, 11 Iesaka, 2002, The effects of tibial component inclination on bone stress after unicompartmental knee arthroplasty, Journal of Biomechanics, 35, 969, 10.1016/S0021-9290(01)00244-5 Taddei, 2006, Subject-specific finite element models of long bones: an in vitro evaluation of the overall accuracy, Journal of Biomechanics, 39, 2457, 10.1016/j.jbiomech.2005.07.018 Lengsfeld, 1998, Comparison of geometry-based and CT voxel-based finite element modelling and experimental validation, Medical Engineering and Physics, 20, 512, 10.1016/S1350-4533(98)00054-X Li, 1999, A validated three-dimensional computational model of a human knee joint, Transactions of the ASME: Journal of Biomechanical Engineering, 121, 657, 10.1115/1.2800871 Douglas, 2002, Ultrasound imaging in lower limb prosthetics, IEEE Transactions on Neural Systems and Rehabilitation Engineering, 10, 11, 10.1109/TNSRE.2002.1021582 Keyak, 1990, Automated three-dimensional finite element modelling of bone: a new method, Journal of Biomedical Engineering, 12, 389, 10.1016/0141-5425(90)90022-F Marks, 1993, The use of strain energy as a convergence criterion in the finite element modelling of bone and the effect of model geometry on stress convergence, Journal of Biomedical Engineering, 15, 474, 10.1016/0141-5425(93)90061-3 Viceconti, 1998, A comparative study on different methods of automatic mesh generation of human femurs, Medical Engineering and Physics, 20, 1, 10.1016/S1350-4533(97)00049-0 Viceconti, 1998, TRI2SOLID: an application of reverse engineering methods to the creation of CAD models of bone segments, Computer Methods and Programs in Biomedicine, 56, 211, 10.1016/S0169-2607(98)00011-X Prevrhal, 1999, Accuracy limits for the determination of cortical width and density: the influence of object size and CT imaging parameters, Physics in Medicine and Biology, 44, 751, 10.1088/0031-9155/44/3/017 Askew, 1981, Analysis of model variables and fixation post length effects on stresses around a prosthesis in the proximal tibia, Transactions of the ASME: Journal of Biomechanical Engineering, 103, 239, 10.1115/1.3138287 Testi, 2001, Border-tracing algorithm implementation for the femoral geometry reconstruction, Computer Methods and Programs in Biomedicine, 65, 175, 10.1016/S0169-2607(00)00125-5 Anderson, 2005, Subject-specific finite element model of the pelvis: development, validation and sensitivity studies, Transactions of the ASME: Journal of Biomechanical Engineering, 127, 364, 10.1115/1.1894148 J.C. Coleman, M.D. Roberts, C.M. Maender, R.T. Hart, Solid Model Creation from CT Image Data, Technical Report TU-BONE-2000-03, Tulane University, 2000. Miyoshi, 2002, Analysis of the shape of the tibial tray in total knee arthroplasty using a three dimension finite element model, Clinical Biomechanics, 17, 521, 10.1016/S0268-0033(02)00064-5 Hodgskinson, 1992, Young's modulus, density and material properties in cancellous bone over a large density range, Journal of Materials Science: Materials in Medicine, 3, 377, 10.1007/BF00705371 Parker, 1997 Viceconti, 1999, CT data sets surface extraction for biomechanical modeling of long bones, Computer Methods and Programs in Biomedicine, 59, 159, 10.1016/S0169-2607(98)00107-2 Fleischmann, 2000, Stair-step artifacts with single versus multiple detector-row helical CT, Radiology, 216, 185, 10.1148/radiology.216.1.r00jn13185 Wang, 1994, Stair-step artifacts in three-dimensional helical CT: an experimental study, Medical Physics, 191, 79 Ploeg, 2004, How accurate are solid models made from CT scan data? Pena, 2005, Finite element analysis of the effect of meniscal tears and meniscectomies on human knee biomechanics, Clinical Biomechanics, 20, 498, 10.1016/j.clinbiomech.2005.01.009 Mehta, 1997, Comparison of image processing techniques (magnetic resonance imaging, computed tomography scan and ultrasound) for 3D modeling and analysis of the human bones, Journal of Digital Imaging, 10, 203, 10.1007/BF03168701 Au, 2005, A parametric analysis of fixation post shape in tibial knee prostheses, Medical Engineering and Physics, 27, 123, 10.1016/j.medengphy.2004.09.010 Camacho, 1997, An improved method for finite element mesh generation of geometrically complex structures with application to the skullbase, Journal of Biomechanics, 30, 1067, 10.1016/S0021-9290(97)00073-0 Schmutz, 2007, The effect of CT slice spacing on the geometry of 3D models B.B. Greer, Finite element modeling and analysis of the proximal femur, Thesis, University of Nevada, Reno, 1999. Kim, 1999, An efficient method of estimating edge locations with subpixel accuracy in noisy images, 589 Kittler, 1983, On the accuracy of the Sobel edge detector, Image and Vision Computing, 37, 10.1016/0262-8856(83)90006-9 Curry, 1990