Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion

Journal of Science and Medicine in Sport - Tập 18 - Trang 262-267 - 2015
Paula C. Charlton1, Benjamin F. Mentiplay1, Yong-Hao Pua2, Ross A. Clark1
1School of Exercise Science, Australian Catholic University, Melbourne, Australia
2Department of Physiotherapy, Singapore General Hospital, Singapore

Tài liệu tham khảo

Verrall, 2007, Hip joint range of motion restriction precedes athletic chronic groin injury, J Sci Med Sport, 10, 463, 10.1016/j.jsams.2006.11.006 Williams, 1978, Limitation of hip joint movement as a factor in traumatic osteitis pubis, Br J Sports Med, 12, 129, 10.1136/bjsm.12.3.129 Verrall, 2005, Hip joint range of motion reduction in sports-related chronic groin injury diagnosed as pubic bone stress injury, J Sci Med Sport, 8, 77, 10.1016/S1440-2440(05)80027-1 Arnason, 2004, Risk factors for injuries in football, Am J Sports Med, 32, 5S, 10.1177/0363546503258912 Hölmich, 1999, Effectiveness of active physical training as treatment for long-standing adductor-related groin pain in athletes: randomised trial, The Lancet, 353, 439, 10.1016/S0140-6736(98)03340-6 Lamontagne, 2009, The effect of Cam FAI on hip and pelvic motion during maximum squat, Clin Orthop Relat Res, 467, 645, 10.1007/s11999-008-0620-x Nussbaumer, 2010, Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients, BMC Muscoskel Disord, 11, 194, 10.1186/1471-2474-11-194 Clapis, 2008, Reliability of inclinometer and goniometric measurements of hip extension flexibility using the modified Thomas test, Physiother Theor Pract, 24, 135, 10.1080/09593980701378256 Franko, 2012, Smartphone app use among medical providers in ACGME training programs, J Med Syst, 36, 3135, 10.1007/s10916-011-9798-7 Clark, 2012, Validity of the Microsoft Kinect for assessment of postural control, Gait Posture, 36, 372, 10.1016/j.gaitpost.2012.03.033 Jacquot, 2012, Measuring the Cobb angle with the iPhone in kyphoses: a reliability study, Int Orthop, 36, 1655, 10.1007/s00264-012-1579-5 Williams, 2013, The TiltMeter app is a novel and accurate measurement tool for the weight bearing lunge test, J Sci Med Sport, 16, 392, 10.1016/j.jsams.2013.02.001 Pua, 2008, Intrarater test–retest reliability of hip range of motion and hip muscle strength measurements in persons with hip osteoarthritis, Arch Phys Med Rehabil, 89, 1146, 10.1016/j.apmr.2007.10.028 Fredericson, 2002, Quantitative analysis of the relative effectiveness of 3 iliotibial band stretches, Arch Phys Med Rehabil, 83, 589, 10.1053/apmr.2002.31606 Ludbrook, 1997, Comparing methods of measurement, Clin Exp Pharmacol Physiol, 24, 193, 10.1111/j.1440-1681.1997.tb01807.x Bland, 1990, A note on the use of the intraclass correlation coefficient in the evaluation of agreement between two methods of measurement, Comput Biol Med, 20, 337, 10.1016/0010-4825(90)90013-F Portney, 2009 Benoit, 2006, Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo, Gait Posture, 24, 152, 10.1016/j.gaitpost.2005.04.012 Ramsey, 1999, Biomechanics of the knee: methodological considerations in the in vivo kinematic analysis of the tibiofemoral and patellofemoral joint, Clin Biomech, 14, 595, 10.1016/S0268-0033(99)00015-7 Patel, 2004, A three-dimensional MRI analysis of knee kinematics, J Orthop Res, 22, 283, 10.1016/j.orthres.2003.08.015