Quantitative assessment of safety barrier performance in the prevention of domino scenarios triggered by fire

Reliability Engineering & System Safety - Tập 143 - Trang 30-43 - 2015
Gabriele Landucci1, Francesca Argenti2, Alessandro Tugnoli3, Valerio Cozzani3
1Dipartimento di Ingegneria Civile e Industriale, Università di Pisa, Largo Lucio Lazzarino 2, 56126 Pisa, Italy
2Dipartimento di Ingegneria Civile e Industriale - Università di Pisa, Largo Lucio Lazzarino 2, 56126 Pisa, Italy
3LISES – Dipartimento di Ingegneria Civile, Chimica, Ambientale e dei Materiali, Alma Mater Studiorum Università di Bologna, via Terracini 28, 40131 Bologna, Italy

Tài liệu tham khảo

Cozzani, 2013, Historical background and state of the art on domino effect assessment, 1 2000 Khan, 1999, The world’s worst industrial accident of the 1990s—what happened and what might have been: a quantitative study, Process Saf Prog, 18, 135, 10.1002/prs.680180304 Lees, 1996 Latha, 1992, Strategies for the quantification of thermally initiated cascade effects, J Loss Prev Proc Ind, 5, 18, 10.1016/0950-4230(92)80061-C Darbra, 2010, Domino effect in chemical accidents: main features and accident sequences, J Hazard Mater, 183, 565, 10.1016/j.jhazmat.2010.07.061 Casal, 2013, Analysis of past accidents and relevant case-histories, 12 Directive 2012/18/EU. European Parliament and Council Directive 2012/18/EU of 4 July 2012 on control of major-accident hazards involving dangerous substances, amending and subsequently repealing council directive 96/82/EC. Official Journal of the European Communities, L 197/1, Brussels, 24.7.2012. Bagster, 1991, The estimation of domino incident frequencies—an approach, Proc Saf Environ Prot, 69/B, 195 Delvosalle C. A methodology for the identification and evaluation of domino effects. Report CRC/MT/003. Brussels, Belgium: Belgian Ministry of Employment and Labour; 1998. 2001 Cozzani, 2005, The assessment of risk caused by domino effect in quantitative area risk analysis, J Hazard Mater, A127, 14, 10.1016/j.jhazmat.2005.07.003 Cozzani, 2013, Threshold-based approach, 189 Roberts A, Medonos S, Shirvill LC. Review of the response of pressurised process vessels and equipment to fire attack (Offshore Technology Report—OTO 2000 051, HSL 2000). Manchester, UK: Health and Safety Laboratory; 2000. Landucci, 2009, The assessment of the damage probability of storage tanks in domino events triggered by fire, Accid Anal Prev, 41, 1206, 10.1016/j.aap.2008.05.006 Birk, 2006 Manu, 2009, Stress rupture predictions of pressure vessels exposed to fully engulfing and local impingement accidental fire heat loads, Eng Fail Anal, 16, 1141, 10.1016/j.engfailanal.2008.07.018 Gledhill J, Lines I. Development of methods to assess the significance of domino effects from major hazard sites (CR Report 183). London, UK: Health and Safety Executive; 1998. Landucci, 2013, Heat radiation effects, 70 Cozzani, 2013, Quantitative assessment of risk caused by domino accidents, 208 2001 De Dianous, 2006, ARAMIS project: a more explicit demonstration of risk control through the use of bow–tie diagrams and the evaluation of safety barrier performance, J Hazard Mater, 130, 220, 10.1016/j.jhazmat.2005.07.010 2009 2008 Dennis, 1996 2008 Townsend W, Anderson CE, Zook J, Cowgill G. Comparison of thermally coated and uninsulated rail tank-cars filled with LPG subjected to a fire environment, Report FRA-OR&D 75-32. Washington, DC: US Department of Transportation; 1974. Droste, 1988, Full scale fire tests with unprotected and thermal insulated LPG storage tanks, J Hazard Mater, 20, 41, 10.1016/0304-3894(88)87005-5 Di Padova, 2011, Identification of fireproofing zones in oil & gas facilities by a risk-based procedure, J Hazard Mater, 191, 83, 10.1016/j.jhazmat.2011.04.043 Tugnoli, 2012, Mitigation of fire damage and escalation by fireproofing: a risk-based strategy, Reliab Eng Syst Saf, 105, 25, 10.1016/j.ress.2011.11.002 Landucci, 2009, Experimental and analytical investigation of thermal coating effectiveness for 3m3 LPG tanks engulfed by fire, J Hazard Mater, 161, 1182, 10.1016/j.jhazmat.2008.04.097 Landucci, 2009, Modeling the performance of coated LPG tanks engulfed in fires, J Hazard Mater, 172, 447, 10.1016/j.jhazmat.2009.07.029 2004 2007 Dowell AM, Dennis PE, Hendershot C. Simplified risk analysis: layer of protection analysis (LOPA). In: AIChE national meeting Indianapolis, IN, paper 281a; November 3–8, 2002. p. 1–6. Bobbio, 2001, Improving the analysis of dependable systems by mapping fault trees into Bayesian networks, Reliab Eng Syst Saf, 71, 249, 10.1016/S0951-8320(00)00077-6 Boudali, 2005, A discrete-time Bayesian network reliability modeling and analysis framework, Reliab Eng Syst Saf, 87, 337, 10.1016/j.ress.2004.06.004 Meel, 2006, Plant-specific dynamic failure assessment using Bayesian theory, Chem Eng Sci, 61, 7036, 10.1016/j.ces.2006.07.007 Schüller, 1997 Khakzad, 2014, Risk management of domino effects considering dynamic consequence analysis, Risk Anal, 34, 1128, 10.1111/risa.12158 Khakzad, 2013, Domino effect analysis using Bayesian networks, Risk Anal, 33, 292, 10.1111/j.1539-6924.2012.01854.x Khakzad, 2012, Dynamic risk analysis using bow-tie approach, Rel Eng Syst Saf, 104, 36, 10.1016/j.ress.2012.04.003 Khakzad, 2013, Risk-based design of process systems using discrete-time Bayesian networks, Rel Eng Syst Safety, 109, 5, 10.1016/j.ress.2012.07.009 1998 1994 2001 1998 2007 1996 2004 2001 2001 2000 2001 Det Norske Veritas. Offshore standard DNV-OS-D301—fire protection, Norway; 2008. International Organization for Standardization. International Standard ISO 13702 – petroleum and natural gas industries – control and mitigation of fires and explosions on offshore production installations—requirements and guidelines. 1st ed. Genève, Switzerland; 1999. 1999 Cozzani, 2009, The development of an inherent safety approach to the prevention of domino accidents, Accid Anal Prev, 41, 1216, 10.1016/j.aap.2008.06.002 1992 Hauptmanns, 2008, Availability analysis for a fixed wet sprinkler system, Fire Saf J, 43, 468, 10.1016/j.firesaf.2008.03.002 1998 1999 1999 1997 Cadwallader, 1995 2000 New Zealand Fire Service Commission Research report number 89—effectiveness of fire safety systems for use in quantitative risk assessment. New York, NY: Marsh and McLennan Companies; 2008. Madonna M, Martella G, Monica L, Maini Pichini E, Tomassini L. The Human factor in risk assessment: methodological comparison between human reliability analysis techniques Italian national institute for occupational safety and prevention (ISPESL). Safety Technologies Department. Rome, Italy. Prevention Today 2009; 5(1/2):67–83. Frank, 2013, A review of sprinkler system effectiveness studies, Fire Sci Rev, 10.1186/2193-0414-2-6 Richardson, 1985, The reliability of automatic sprinkler systems, vol. 238 Finucane, 1987 Shirvill, 2004, Efficacy of water spray protection against propane and butane jet fires impinging on LPG storage tanks, J Loss Prev Proc Ind, 17, 111, 10.1016/j.jlp.2003.10.004 Roberts, 2004, Directed deluge system designs and determination of the effectiveness of the currently recommended minimum deluge rate for the protection of LPG tanks, J Loss Prev Proc Ind, 17, 103, 10.1016/j.jlp.2003.10.005 Roberts, 2004, Effectiveness of an enhanced deluge system to protect LPG tanks and sensitivity to blocked nozzles and delayed deluge initiation, J Loss Prev Proc Ind, 17, 151, 10.1016/j.jlp.2003.10.009 Hankinson, 2004, Effectiveness of area and dedicated water deluge in protecting objects impacted by crude oil/gas jet fires on offshore installations, J Loss Prev Proc Ind, 17, 119, 10.1016/j.jlp.2003.10.003 Paltrinieri, 2009, Risk reduction in road and rail LPG transportation by passive fire protection, J Hazard Mater, 167, 332, 10.1016/j.jhazmat.2008.12.122 Gomez-Mares, 2012, Performance assessment of passive fire protection materials, Ind Eng Chem Res, 51, 7679, 10.1021/ie201867v Gomez-Mares, 2012, Behavior of intumescent epoxy resins in fireproofing applications, J Anal Appl Pyrolysis, 97, 99, 10.1016/j.jaap.2012.05.010 Jimenez, 2006, Intumescent fire protective coating: toward a better understanding of their mechanism of action, Thermochim Acta, 449, 16, 10.1016/j.tca.2006.07.008 Flynn, 2009 Hobert FA, Molag M. Fire Brigade response and deployment scenarios to avoid a hot BLEVE of a LPG tank vehicle or a LPG tank wagon. TNO-report 200G4-R0069/B. Apeldoorn, The Netherlands: TNO Build Environment and Geosciences; 2006. U.S. Fire Administration/National Fire Data Center . Structure fire response time. Topical fire research series. Emmitsburg, MD, USA: U.S. Department of Homeland Security United States Fire Administration, National Fire Data Center; 2006. 2004 Uijt de Haag, 1999 Alber, 1995 1976 Marryatt, 1988 1978 Miller, 1973 United States Dept. of Energy (DOE), Office of the Assistant Secretary for Environmental Protection, Safety and Emergency Preparedness. Automatic sprinkler system performance and reliability in United States Department of Energy Facilities. 1952-1980 DOE/EP-0052. Washington, DC: US DOE; 1982. Argenti F, Landucci G. Probabilistic assessment of fire protection systems adopted in the process industries—University of Pisa internal Report 2014/01. Pisa, Italy: University of Pisa, Department of Civil and Industrial Engineering; 2014. Necci, 2014, Accident scenarios triggered by lightning strike on atmospheric storage tanks, Rel Eng Syst Safety, 127, 30, 10.1016/j.ress.2014.02.005