Improving Pacemaker Therapy in Congenital Heart Disease: Contractility and Resynchronization

Pediatric Cardiac Surgery Annual - Tập 18 - Trang 51-56 - 2015
Peter P. Karpawich1
1Section of Cardiology, Department of Pediatrics, The Children’s Hospital of Michigan, Wayne State University School of Medicine, Detroit, MI

Tài liệu tham khảo

Furman, 1959, An intracardiac pacemaker for Stokes-Adams seizures, N Engl J Med, 261, 943, 10.1056/NEJM195911052611904 Hunter, 1959, A bipolar myocardial electrode for complete heart block, Lancet, 79, 506 Adomian, 1986, Myofibrillar disarray produced in normal hearts by chronic electrical pacing, Am Heart J, 112, 79, 10.1016/0002-8703(86)90682-4 Karpawich, 1999, Altered cardiac histology following apical right ventricular pacing in patients with congenital atrioventricular block, Pacing Clin Electrophysiol, 22, 1372, 10.1111/j.1540-8159.1999.tb00631.x Prinzen, 1990, Redistribution of myocardial fiber strain and blood flow by asynchronous activation, Am J Physiol, 259, 330 Tse, 1997, Long-term effect of right ventricular pacing on myocardial perfusion and function, J Am Coll Cardiol, 29, 744, 10.1016/S0735-1097(96)00586-4 Tantengco, 2001, Left ventricular dysfunction after long-term right ventricular apical pacing in the young, J Am Coll Cardiol, 37, 2093, 10.1016/S0735-1097(01)01302-X Karpawich, 1992, Septal His-purkinje ventricular pacing in canines: a new endocardial electrode approach, Pacing Clin Electrophysiol, 15, 2011, 10.1111/j.1540-8159.1992.tb03012.x Lieberman, 2004, Selective Site Pacing: Defining and reaching the selected site, Pacing Clin Electrophysiol, 26, 883, 10.1111/j.1540-8159.2004.00551.x Deshmukh, 2004, Direct His-bundle pacing: Present and future, Pacing Clin Electrophysiol, 27, 862, 10.1111/j.1540-8159.2004.00548.x Manolis, 2006, The deleterious consequences of right ventricular apical pacing: Time to seek alternate site pacing, Pacing Clin Electrophysiol, 29, 298, 10.1111/j.1540-8159.2006.00338.x Behan, 2006, Cardiac resynchronization therapy for heart failure, Int J Clin Pract, 60, 1107, 10.1111/j.1742-1241.2006.01015.x Birnie, 2006, The problem with non-response to cardiac resynchronization therapy, Curr Opin Cardiol, 21, 20, 10.1097/01.hco.0000198983.93755.99 Pires, 2006, Am Heart J, 51, 837, 10.1016/j.ahj.2005.06.024 Karpawich, 1992, DL: Improved chronic epicardial pacing in children: steroid contribution to porous platinized electrodes, Pacing Clin Electrophysiol, 15, 1151, 10.1111/j.1540-8159.1992.tb03118.x Horenstein, 2003, Chronic performance of steroid-eluting epicardial leads in a growing pediatric population: a 10-year comparison, Pacing Clin Electrophysiol, 26, 1467, 10.1046/j.1460-9592.2003.t01-1-00212.x Khan, 2010, Performance of the Lumenless 4.1fr diameter pacing lead implanted at alternate pacing sites in congenital heart: a chronic 5 year comparison, Pacing Clin Electrophysiol, 33, 1467, 10.1111/j.1540-8159.2010.02884.x Wiggers, 1925, The muscle reactions of the mammalian ventricles to artificial surface stimulation, Am J Physiol, 73, 346, 10.1152/ajplegacy.1925.73.2.346 Padeletti, 2006, Physiologic pacing: new modalities and pacing sites, Pacing Clin Electrophysiol, 29, S72 Bleeker, 2004, Relationship between QRS duration and left ventricular dyssynchrony in patients with end-stage heart failure, J Cardiovasc Electrophysiol, 15, 544, 10.1046/j.1540-8167.2004.03604.x Lieberman, 2006, Ventricular pacing lead location alters systemic hemodynamics and left ventricular function in patients with and without reduced ejection fraction, J Am Coll Cardiol, 48, 1634, 10.1016/j.jacc.2006.04.099 Mason, 1971, Assessment of cardiac contractility: the relation between the rate of pressure rise and ventricular pressure during isovolumic systole, Circulation, 44, 47, 10.1161/01.CIR.44.1.47 Giudici, 1999, Alternative site pacing: it’s time to define terms, Pacing Clin Electrophysiol, 22, 551, 10.1111/j.1540-8159.1999.tb00495.x Karpawich PP, Singh H, Zelin K: Optimizing paced ventricular function in patients with and without repaired congenital heart disease by contractility-guided lead implant. Pacing Clin Electrophysiol 2015;38:54–62 Mond, 2007 Dodge-Khatami, 2005, Left heart atrial and ventricular epicardial pacing through a left lateral thoracotomy in children: a safe approach with excellent functional and cosmetic results, Eur J Cardio Thorac Surg, 28, 541, 10.1016/j.ejcts.2005.06.040 Peschar, 2003, Left ventricular septal and apex pacing for optimal pump function in canine hearts, J Am Coll Cardiol, 41, 1218, 10.1016/S0735-1097(03)00091-3 Silvetti MS, Di Carlo D, Ammirati A, et al: Left ventricular pacing in neonates and infants with isolated congenital complete or advanced atrioventricular block: short- and medium-term outcome. Europace 2014; http://dx.doi.org/10.1093/europace/euu180. 12 August 2014. pii: euu180 [Epub ahead of print] Serwer, 1988, Epicardial ventricular pacemaker electrode longevity in children, Am J Cardiol, 61, 104, 10.1016/0002-9149(88)91313-6 Gillette, 1988, Pediatric transvenous pacing: a concern for venous thrombosis?, Pacing Clin Electrophysiol, 11, 1935, 10.1111/j.1540-8159.1988.tb06331.x Kanmmeraad, 2004, Endocardial pacemaker implantation in infants weighing < 10 kilograms, Pacing Clin Electrophysiol, 27, 1466, 10.1111/j.1540-8159.2004.00663.x Stojanov, 2008, Permanent endovenous pediatric pacing: absence of lead failure – 20 years followup, Pacing Clin Electrophysiol, 31, 495, 10.1111/j.1540-8159.2008.01148.x Sanjeev, 2006, Superior vena cava and innominate vein dimensions in growing children: an aid for interventional devices and transvenous leads, Pediatr Cardiol, 27, 414, 10.1007/s00246-006-1133-6 Antretter, 2001, Inferior vena caval loop of an endocardial pacing lead did not solve the growth problem in a child, Pacing Clin Electrophysiol, 24, 1706, 10.1046/j.1460-9592.2001.01706.x Bar-Cohen, 2006, Age, size and lead factors alone do not predict venous obstruction in children and young adults with transvenous lead systems, J Cardiovasc Electrophysiol, 17, 754, 10.1111/j.1540-8167.2006.00489.x Bharmanee, 2013, Comparative chronic effects on atrioventricular valve integrity between standard 5-7 French and the new 4.1 French diameter pacing leads in the young [abstract], Circulation, 28 Janoušek, 2013, Permanent cardiac pacing in children: choosing the optimal pacing site: a multicenter study, Circulation, 127, 613, 10.1161/CIRCULATIONAHA.112.115428 Dubin, 2005, Resynchronization therapy in pediatric and congenital heart patients: an international multicenter study, J Am Coll Cardiol, 46, 2277, 10.1016/j.jacc.2005.05.096 Khairy, 2006, Cardiac resynchronization therapy in congenital heart disease, Int J Cardiol, 109, 160, 10.1016/j.ijcard.2005.06.065 Cecchin, 2009, Cardiac resynchronization therapy (and multisite pacing) in pediatrics and congenital heart disease: Five years experience in a single institution, J Cardiovasc Electrophysiol, 20, 58, 10.1111/j.1540-8167.2008.01274.x Janousek, 2009, Cardiac resynchronisation therapy in paediatric and congenital heart disease: differential effects in various anatomical and functional substrates, Heart, 95 Karpawich, 2014, Improved resynchronization pacing efficacy among congenital heart disease patients with refractory heart failure [abstract], J Heart Dis, 11, 9 Khairy P, Van Hare GF, Balaji S, et al. PACES/HRS expert consensus statement on the recognition and management of arrhythmias in adult congenital heart disease. Heart Rhythm 2014;11(10):e102–e165