Metal-on-metal bearings total hip arthroplasty: The cobalt and chromium ions release concern
Tài liệu tham khảo
Schmalzried, 1992, Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space, J Bone Joint Surg (Am), 74, 849, 10.2106/00004623-199274060-00006
Weber, 1996, Experience with the Metasul total hip bearing system, Clin Orthop, 329, S69, 10.1097/00003086-199608001-00007
Levai JP. Les prothèses totales métal-métal de hanche. In: Duparc J (ed.). Cahiers d’enseignement de la SOFCOT; 2008, p. 85–96.
Doorn, 1998, Metal wear particle characterization from metal-on-metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles, J Biomed Mater Res, 42, 103, 10.1002/(SICI)1097-4636(199810)42:1<103::AID-JBM13>3.0.CO;2-M
Brodner, 1997, Elevated serum cobalt with metal-on-metal articulating surfaces, J Bone Joint Surg (Br), 79, 316, 10.1302/0301-620X.79B2.7326
Jacobs, 2003, Metal degradation products: a cause for concern in metal-metal bearings?, Clin Orthop, 417, 139, 10.1097/01.blo.0000096810.78689.62
Grübl, 2007, Long-term follow-up of metal-on-metal total hip replacement, J Orthop Res, 25, 841, 10.1002/jor.20381
Clarke, 2003, Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty, J Bone Joint Surg (Br), 85, 913, 10.1302/0301-620X.85B6.14166
Passuti, 2007, Le frottement métal-métal en arthroplastie de hanche. Aspect de matériovigilance, Rev Chir Orthop, 93, 288
Goullé, 2008, Dosage multiélémentaire dans le plasma et le sang total par ICP-MS : influence du matériel de prélèvement, Ann Toxicol Anal, 20, 97, 10.1051/ata/2009007
Lauwerys R. Le chrome – prévention – Toxicologie industrielle et intoxications professionnelles, 5e édition 2007, Masson edt.:252–4.
Lauwerys R. Le cobalt – surveillance médicale – Toxicologie industrielle et intoxications professionnelles, 5e édition 2007, Masson edt.:266–7.
Fiche Biotox du cobalt, guide biotoxicologique pour les médecins du travail – INRS Institut national de recherche et sécurité, http://www.inrs.fr/htm/cobalt_et_composes_mineraux.html; 2009.
Fiche Biotox du chrome, guide biotoxicologique pour les médecins du travail – INRS Institut national de recherche et sécurité, http://www.inrs.fr/htm/cobalt_et_composes_mineraux.html; 2009.
Hallab, 2005, Lymphocyte response in patients with total hip arthroplasty, J Orthop Res, 23, 384, 10.1016/j.orthres.2004.09.001
Hart, 2009, Circulating levels of cobalt and chromium from metal-on-metal hip replacement are associated with CD8+ T-cell lymphopenia, J Bone Joint Surg (Br), 91, 835, 10.1302/0301-620X.91B6.21844
Willert, 2005, Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study, J Bone Joint Surg (Am), 87, 28, 10.2106/JBJS.A.02039pp
Luo, 2005, Effect of cobalt and chromium ions on MMP-1, TIMP-1, and TNF-α gene expression in human U937 macrophages. A role for tyrosine kinases, Biomaterial, 26, 5587, 10.1016/j.biomaterials.2005.02.013
Engh, 2010, Metal-on-metal hip arthroplasty: does early clinical outcome justify the chance of an adverse local tissue reaction?, Clin Orthop Relat Res, 468, 406, 10.1007/s11999-009-1063-8
Daley, 2004, Wear debris from hip or knee replacement causes chromosomal damage in human cells in tissue culture, J Bone Joint Surg (Br), 86, 598, 10.1302/0301-620X.86B4.14368
Ladon, 2004, Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty, J Arthroplasty, 19, 78, 10.1016/j.arth.2004.09.010
Dunstan, 2008, Chromosomal aberrations in the peripheral blood of patients with metal-on-metal hip bearings, J Bone Joint Surg (Am), 90, 517, 10.2106/JBJS.F.01435
Ladon D, Bhamra M, Turner J, Case CP. Changes in chromosome aberrations and metal levels in the peripheral blood of patients after ceramic-on-ceramic hip replacement. Poster 1145, 51st Annual Meeting of the Orthopaedic research Society.
Keegan, 2007, Orthopaedic metals and their potential toxicity in the arthroplasty patient. A review of current knowledge and future strategies, J Bone Joint Surg (Br), 89, 567, 10.1302/0301-620X.89B5.18903
Brodner, 2004, Does the placenta inhibit the passage of chromium and cobalt after metal-on-metal total hip arthroplasty?, J Arthroplasty, 19, 102, 10.1016/j.arth.2004.09.020
Ziaee, 2007, Transplacental transfer of cobalt and chromium in patients with metal-on-metal hip arthroplasty: a controlled study, J Bone Joint Surg (Br), 89, 301, 10.1302/0301-620X.89B3.18520
Visuri, 1996, Cancer risk after metal-on-metal and polyethylene on metal total hip arthroplasty, Clin Orthop, 329, S280, 10.1097/00003086-199608001-00025
Visuri, 2006, Cancer incidence and causes of death among total hip replacement patients: a review based on Nordic cohorts with a special emphasis on metal-on-metal bearings. Proc. ImechE, J Eng Med, 220, 399, 10.1243/095441105X63282
Boardman, 2005, A benign psoas mass following metal-on-metal resurfacing of the hip, J Bone Joint Surg (Br), 88, 402
Pandit, 2008, Pseudotumours associated with metal-on-metal hip resurfacings, J Bone Joint Surg (Br), 90, 847, 10.1302/0301-620X.90B7.20213
Grosclaude, 2006, Masse inguinale révélatrice d’une complication d’une arthroplastie totale de hanche, Rev Chir Orthop, 92, 351
Hananouchi, 2005, Huge pelvic mass secondary to wear debris causing ureteral obstruction, J Arhroplasty, 19, 946, 10.1016/j.arth.2004.11.005
Howie, 1991, Pseudo-abscess of the psoas bursa in failed double-cup arthroplasty of the hip, J Bone Joint Surg (Br), 73, 29, 10.1302/0301-620X.73B1.1991769
Kolmert, 1984, Ileopectinal bursitis following total hip replacement, Acta Orthop Scand, 55, 63, 10.3109/17453678408992314
Farrington, 2002, Giant synovial cyst causing femoral occlusion following a hip replacement. A case report and review of the literature, Hip Int, 2, 394, 10.1177/112070000201200408
Mikhael, 2009, Failure of metal-on-metal total hip arthroplasty mimicking hip infection. A report of two cases, J Bone Joint Surg (Am), 9, 443, 10.2106/JBJS.H.00603
Peacock, 2008, Reactive synovitis following hip resurfacing: a case presentation, Hip Int, 18, 224, 10.5301/HIP.2008.3823
Butler, 2004, Total hip wear debris presenting as lower extremity swelling. A report of two cases, J Bone Joint Surg (Am), 86, 142, 10.2106/00004623-200401000-00022
Harvie, 2008, The treatment of femoral neuropathy due to pseudotumour caused by metal-on-metal resurfacing arthroplasty, Hip Int, 18, 313, 10.5301/HIP.2008.2784
Clayton, 2008, Inflammatory pseudotumeur associated with femoral nerve palsy following metal-on-metal resurfacing of the hip, J Bone Joint Surg (Am), 90, 1988, 10.2106/JBJS.G.00879
Gruber, 2007, Cystic lesion of the groin due to metallosis: a rare long-term complication of metal-on-metal total hip arthroplasty, J Arthroplasty, 22, 923, 10.1016/j.arth.2006.10.002
Matsumoto, 1992, Illiopsoas bursal distension caused by acetabular loosening after total hip arthroplasty. A rare complication after total hip arthroplasty, Clin Orthop, 279, 144, 10.1097/00003086-199206000-00018
Hart, 2009, The painful metal-on-metal hip resurfacing, J Bone Joint Surg (Br), 91, 738, 10.1302/0301-620X.91B6.21682
Shukla, 2005, Biocompatibility of gold nanoparticles and their endocytotic fate inside the cellular compartment: a microscopic overview, Langmuir, 21, 10644, 10.1021/la0513712
Brown, 2006, Biological effects of clinically relevant wear particles from metal-on-metal hip prostheses, Proc Inst Mech Eng H, 220, 355, 10.1243/095441105X63291
Trindade, 2001, Interleukin-10 inhibits polymethylmethacrylate particle induced interleukin-6 and tumor necrosis factor-alpha release by human monocyte/macrophages in vitro, Biomaterials, 22, 2067, 10.1016/S0142-9612(00)00376-8
Kwon, 2009, Dose-dependant cytotoxicity of clinically relevant cobalt nanoparticles and ions on macrophages in vitro, Biomed Mater, 4, 25018, 10.1088/1748-6041/4/2/025018
Glyn-Jones, 2009, Risk factors for inflammatory pseudotumour formation following hip resurfacing, J Bone Joint Surg (Br), 91, 1566, 10.1302/0301-620X.91B12.22287
Grammatopoulos, 2009, Hip resurfacing revised for inflammatory pseudotumour have a poor outcome, J Bone Joint Surg (Br), 91, 1019, 10.1302/0301-620X.91B8.22562
Laudrin, 2008, Absence d’ostéolyse et de descellement d’une arthroplastie bilatérale de Mac Kee-Farrar à 34 ans de recul, Rev Chir Orthop, 94, 87
Zicat, 1995, Patterns of osteolysis around total hip components inserted with and without cement, J Bone Joint Surg (Am), 77, 432, 10.2106/00004623-199503000-00013
Beldame, 2009, Cementless cups do not increase osteolysis risk in metal-on-metal total hip arthroplasty, Orthop Traumatol Surg Res, 95, 478, 10.1016/j.otsr.2009.07.007
Lazennec, 2007, Second generation of metal-on-metal cemented total hip replacements: 12 years of clinical and biological follow-up, Interact Surg, 2, 178, 10.1007/s11610-007-0058-y
Milosev, 2006, Survivorship and retrieval analysis of Sikomet metal-on-metal total hip replacements at a mean of 7 years, J Bone Joint Surg (Am), 88, 1173, 10.2106/JBJS.E.00604
Nich, 2006, Arthroplastie de hanche à couple métal-métal sur polyéthylène cimenté. Résultats à moyen terme, Rev Chir Orthop, 92, 118
Gruen, 1979, Modes of failure of cemented stem-type femoral components: a radiographic analysis of loosening, Clin Orthop, 141, 17
DeLee, 1976, Radiographical demarcation of cemented sockets in total hip replacement, Clin Orthop, 121, 29
Levai, 2006, Échec par descellement aseptique précoce de la cupule acétabulaire cimentée de prothèse totale de hanche à couple de frottement métal-métal, Rev Chir Orthop, 92, 575
Long, 2004, An American experience with metal-on-metal total hip arthroplasties: a 7-year follow-up study, J Arthroplasty, 19, 29
Girard J, Combes A, Herent S, Migaud H. Metal-on-metal cups cemented into reinforcement rings: a possible new acetabular reconstruction procedure for young and active patients. J Athroplasty 2010;25: doi:10.1016/j.arth.2009.08.024. In press.
Delaunay, 2004, Metal-on-metal bearings in cementless primary total hip arthroplasty, J Arthroplasty, 19, 34
Delaunay, 2008, THA using metal-on-metal articulation in active patients younger than 50 years, Clin Orthop, 466, 340, 10.1007/s11999-007-0045-y
Eswaramoorthy, 2008, The Metasul metal-on-metal articulation in primary total hip replacement. Clinical and radiological results at 10 years, J Bone Joint Surg (Br), 90, 1278, 10.1302/0301-620X.90B10.20378
Sharma, 2007, Metal-on-metal total hip joint replacement: a minimum follow-up of 5 years, Hip Int, 17, 70, 10.5301/HIP.2008.5558
Migaud, 2004, Cementless metal-on-metal hip arthroplasty in patients less than 50 years of age: comparison with a matched control group using ceramic-on-polyethylene after a minimum 5-year follow-up, J Arthroplasty, 19, 23
Goetz, 1994, The prevalence of femoral osteolysis associated with components inserted with or without cement in total hip replacement. A retrospective matched-pair series, J Bone Joint Surg (Am), 76, 1121, 10.2106/00004623-199408000-00002
Holloway, 2009, Osteolysis with a cementless second generation metal-on-metal cup in total hip replacement, Int Orthop, 33, 1537, 10.1007/s00264-008-0679-8
Carr, 2008, Osteolysis in patients with a metal-on-metal hip arthroplasty, ANZ J Surg, 78, 144, 10.1111/j.1445-2197.2007.04390.x
Park, 2005, Early osteolysis following second-generation metal-on-metal hip replacement, J Bone Joint Surg (Am), 87, 1514, 10.2106/JBJS.D.02641
Korovessis, 2006, Metallosis after contemporary metal-on-metal total hip arthroplasty, J Bone Joint Surg (Am), 88, 1183, 10.2106/JBJS.D.02916
Neumann, 2009, Long-term results of a contemporary metal-on-metal total hip arthroplasty. A 10-year follow-up study, J Arthroplasty, 24, 1
Amstutz, 2008, Eleven years of experience with metal-on-metal hybrid hip resurfacing: a review of 1000 conserve plus, J Arthroplasty, 23, 36, 10.1016/j.arth.2008.04.017
Heilpern, 2009, Birmingham hip resurfacing arthroplasty. A series of 110 consecutive hips with a minimum 5-year clinical and radiological follow-up, J Bone Joint Surg (Br), 90, 1137
Treacy, 2005, Birmingham hip resurfacing arthroplasty. A minimum follow-up of 5 years, J Bone Joint Surg (Br), 87, 167, 10.1302/0301-620X.87B2.15030
Steffen, 2008, The 5-year results of the Birmingham hip resurfacing arthroplasty. An independent series, J Bone Joint Surg (Br), 90, 436, 10.1302/0301-620X.90B4.19648
Rieker, 2005, Influence of the clearance on in-vitro tribology of large diameter metal-on-metal articulations pertaining to resurfacing hip implants, Orthop Clin North Am, 36, 135, 10.1016/j.ocl.2005.02.004
Dowson, 2006, Tribological principles in metal-on-metal hip joint design, Proc Inst Mech Eng H, 220, 161, 10.1243/095441105X63255
Smith, 2001, The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements, Proc Inst Mech Eng H, 215, 161, 10.1243/0954411011533724
Back, 2005, How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing?, Clin Orthop, 438, 177, 10.1097/01.blo.0000166901.84323.5d
Witzleb, 2006, Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty, Acta Orthop, 77, 697, 10.1080/17453670610012863
Jacobs, 1995, Local and distant products from modularity, Clin Orthop, 319, 94
Vendittoli, 2010, Randomised study comparing metal ion release from bearing wear and corrosion with 28mm and large diameter metal-on-metal bearing articulations, J Bone Joint Surg (Br), 92, 12, 10.1302/0301-620X.92B1.22226
Vendittoli, 2007, Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip, J Bone Joint Surg (Br), 89, 441, 10.1302/0301-620X.89B4.18054
Vendittoli PA, Amzica T, Roy AG, Lusignan D, Girard J, Lavigne M. Metal ion release with large-diameter metal-on-metal hip arthroplasty. J Arthroplasty 2010;25 :doi:10.1016/j.arth.2010 Mar 3 [Epub ahead of print].
Dunstan, 2005, Metal ion levels after metal-on-metal proximal femoral replacements: a 30-year follow-up, J Bone Joint Surg (Br), 87, 628, 10.1302/0301-620X.87B5.15384
Redline, 1986, Granulomatous disease associated with pulmonary deposition of titanium, Br J Ind Med, 43, 652
La Budde, 1994, Particulate titanium and cobalt-chrome metallic debris in failed total knee arthroplasty. A quantitative histologic analysis, J Arthroplasty, 9, 291, 10.1016/0883-5403(94)90084-1
Luetzner, 2007, Serum metal ion exposure after total knee arthroplasty, Clin Orthop, 461, 136, 10.1097/BLO.0b013e31806450ef
Del Rio, 2007, Metal levels in corrosion of spinal implants, Eur Spine J, 16, 1055, 10.1007/s00586-007-0311-4
Richardson, 2008, Serum titanium levels after instrumented spinal arthrodesis, Spine, 33, 792, 10.1097/BRS.0b013e318169574d
Patton, 2008, Levels of systemic metal ions in patients with intramedullary nails, Acta Orthop, 79, 820, 10.1080/17453670810016911