Functional electrical stimulation for grasping and walking: indications and limitations
Tóm tắt
Từ khóa
Tài liệu tham khảo
Kantrowitz A . Electronic Physiological Aids Report on the Maimonides Hospital Brooklyn 1960 4–5
Baker L et al. Neuromuscular Electrical Stimulation – A Practical Guide 3rd edn USA: Rehabilitation Engineering Program, Los Amigos Research and Education Institute, Rancho Los Amigos Medical Center 1993
Guyton A, Hall J Textbook of Medical Physiology 9th edn W.B. Saunders Company 1996
Quintern J . Application of functional electrical stimulation in paraplegic patients NeuroRehabilitation 1998 10: 205–250
Cameron T et al. Micromodular implants to provide electrical stimulation of paralyzed muscles and limbs IEEE Tr Biomed Eng 1997 44: 781–790
Hoshiyama N, Handa Y . A master-slave type multichannel functional electrical stimulation (FES) system for the control of the paralyzed upper extremities Automedica 1989 11: 209–220
Smith B, Peckham P, Keith M, Roscoe D . An externally powered, multichannel, implantable stimulator for versatile control of paralyzed muscle IEEE Tr Biomech Eng 1987 34: 499–508
Tyler D, Durand A . A slowly penetrating interfascicular nerve electrodes for selective activation of peripheral nerves IEEE Tr Rehab Eng 1997 5: 51–61
Kobetic R, Morsolais E . Synthesis of paraplegic gait with multichannel functional neuromuscular stimulation IEEE Tr Rehab Eng 1994 2: 66–78
Mortimer J . Motor prostheses Handbook of Physiology – The Nervous System II American Physiological Society 1981 pp 155–187
Ditunno JF, Young W, Donovan WH, Creasy G . The International Standards Booklet for Neurological and Functional Classification of Spinal Cord Injury Paraplegia 1994 32: 70–80
Sollerman C, Ejeskar A . Sollerman hand function test: A standardized method and its use in tetraplegic patients Scand J Plast Reconstr Surg Hand Surg 1995 29: 167–176
Ditunno JF et al. Walking Index for Spinal Cord Injury (WISCI): An international multicenter validity and reliability study Spinal Cord 2000 38: 234–243
Rutz S, Dietz V, Curt A . Diagnostic and prognostic value of compound motor action potential of lower limbs in acute paraplegic patients Spinal Cord 2000 38: 203–210
Curt A, Dietz V . Traumatic cervical spinal cord injury: relation between somatosensory-evoked potentials, neurological deficits, and hand function Arch Phys Med Rehabil 1996 77: 48–53
Curt A, Dietz V . Neurographic assessment of intramedullar motoneurone lesions in cervical spinal cord injury: consequences for hand function Spinal Cord 1996 34: 326–332
Curt A, Dietz V . Nerve conduction in cervical spinal cord injury: significance for hand function NeuroRehabilitation 1996 7: 165–173
Curt A, Dietz V . Ambulatory capacity in spinal cord injury: significance of somatosensory evoked potentials and ASIA protocols in predicting outcome Arch Phys Med Rehabil 1997 78: 39–43
Curt A, Keck M, Dietz V . Clinical value of F-wave recordings in traumatic cervical spinal cord injury Electroenceph Clin Neurophysiol 1997 105: 189–193
Curt A, Dietz V . Electrophysiological recordings in patients with spinal cord injury: significance for predicting outcome Spinal Cord 1999 37: 157–165
Dietz V . Neurophysiology of gait disorders: present and future applications Electroenceph Clin Neurophysiol 1997 103: 333–335
Popovic MR et al. Surface-stimulation technology for grasping and walking neuroprostheses IEEE Eng Med Biol Magazine 2001 20: 82–93
Bajd T et al. Use of functional electrical stimulation in the rehabilitation of patients with incomplete spinal cord injuries J Biomed Eng 1989 11: 96–102
Ijzerman M et al. The NESS Handmaster orthosis: restoration of hand function in C5 and stroke patients by means of electrical stimulation J Rehabil Sci 1996 9: 86–89
Prochazka A, Gauthier M, Wieler M, Kanwell Z . The Bionic Glove: An electrical stimulator garment that provides controlled grasp and hand opening in quadriplegia Arch Phys Med Rehabil 1997 78: 1–7
Graupe D, Davis R, Kordylewski H, Kohn KH . Ambulation by traumatic T4-12 paraplegics using functional neuromuscular stimulation Crit Rev Neurosurg 1998 8: 221–231
Graupe D, Kohn KH . Functional neuromuscular stimulator for short-distance ambulation by certain thoracic-level spinal-cord-injured paraplegics Surg Neurol 1998 50: 202–207
Wieler M, Naaman S, Stein RB . WalkAid: An improved functional electrical stimulator for correcting foot-drop Proceedings of the 1st Annual Conference of the International FES Society 1996 pp 101–104
Taylor PN et al. Correction of bilateral dropped foot using the Odstock 2 channel stimulator (O2CHS) Proceedings of the 4th Annual Conference of the International FES Society 1999 pp 257–260
Davis R, Houdayer T, Andrews B, Barriskill A Paraplegia: implanted Praxis24–FES system for multi-functional restoration Proceedings of the 4th Annual Conference of the International FES Society 1999 pp 155–158
Kobetic R, Triolo R, Morsolais E . Muscle selection and walking performance of multichannel FES systems for ambulation in paraplegia IEEE Tr Rehab Eng 1997 5: 23–28
Taylor P, Esnouf J, Hobby J . Pattern of use and user satisfaction of neuro control freehand system Spinal Cord 2001 39: 156–160
Haugland M, Lickel A, Haase J, Sinkjaer T . Control of FES thumb force using slip information obtained from the cutaneous electroneurogram in quadriplegic man IEEE Tr Rehab Eng 1999 7: 215–227
Lickel A . Restoration of lateral hand grasp in a tetraplegic patient applying natural sensory feedback. Center for sensory-motor interaction SMI, Aalborg University, Denmark 1998
Catz A et al. SCIM – Spinal Cord Independence Measure: a new disability scale for patients with spinal cord lesions Spinal Cord 1997 35: 850–856
Rebersk S, Vodovnik L . Proportionally controlled functional electrical stimulation of hand Arch Phys Med Rehabil 1973 54: 168–172
Popovic D et al.. Clinical evaluation of the Belgrade Grasping System. Proceedings of the 6th Vienna International Workshop on FES1998 pp 247–250
Hart RL, Kilgore KL, Peckham PH . A comparison between control methods for implanted FES hand-grasp systems IEEE Tr Rehab Eng 1998 6: 208–218
Grill JH, Peckham PH . Functional neuromuscular stimulation for combined control of elbow extension and hand grasp in C5 and C6 quadriplegics IEEE Tr Rehab Eng 1998 6: 190–199
Liberson WT, Holmquest HJ, Scot D, Dow M . Functional electrotherapy: Stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients Arch Phys Med Rehabil 1961 42: 101–105
Vodovnik L et al. Recent applications of functional electrical stimulation to stroke patients in Ljubljana Clin Orthopaed Related Res 1978 131: 64–70
MicroFES – Manual. Institut ‘Jozef Stefan’ Ljubljana, Slovenia 1991
Solomonow M et al. Reciprocating gait orthosis powered with electrical muscle stimulation (RGO II) Part I: Performance evaluation of 70 paraplegic patients Orthopaedics 1997 20: 315–324
Solomonow M et al. Reciprocating gait orthosis powered with electrical muscle stimulation (RGO II) Part II: Medical evaluation of 70 paraplegic patients Orthopedics 1997 20: 411–418
Popovic D, Tomovic R, Schwirtlich L . Hybrid assistive system – the motor neuroprosthesis IEEE Tr Biomed Eng 1989 36: 729–737
Kralj A, Bajd T, Turk R . Enhancement of gait restoration in spinal injured patients by functional electrical stimulation Clin Orthopaed Related Res 1988 223: 34–43
Bajd T, Kralj A, Stefancic M, Lavrac N . Use of functional electrical stimulation in the lower extremities of incomplete spinal cord injured patients Artificial Organs 1999 23: 403–409
Phillips CA . An interactive system of electrical stimulators and gait orthosis for walking in the spinal cord injured Automedica 1989 11: 247–261