Online monitoring in continuous renal replacement therapies

Kidney International - Tập 56 - Trang S8-S14 - 1999
Claudio Ronco, Alessandra Brendolan, Rinaldo Bellomo

Tài liệu tham khảo

Ronco, 1993, Management of acute renal failure in the critically ill patient, 630 Bellomo, 1995, Acute renal failure in the intensive care unit: Which treatment is the best?, vol 20, 385 Ronco, 1995, Adequacy of renal replacement therapy,, vol 20, 364 Ronco, 1994, Continuous renal replacement therapies in the treatment of acute renal failure in intensive care patients. II. Clinical indications and prescription, Nephrol Dial Transplant, 9, 201 Ronco, 1996, Complications with continuous renal replacement therapies, Am J Kidney Dis, 28, 100, 10.1016/S0272-6386(96)90087-6 Kramer, 1977, Arteriovenous hemofiltration: A new and simple method for treatment of over hydrated patients resistant to diuretics, Klin Wochenschr, 55, 1121, 10.1007/BF01477940 Lauer, 1983, Continuous arterio-venous hemofiltration in the critically ill patient, Ann Intern Med, 99, 455, 10.7326/0003-4819-99-4-455 Kaplan, 1984, Continuous arterio-venous hemofiltration, Ann Intern Med, 100, 358, 10.7326/0003-4819-100-3-358 Ronco, 1994, Continuous renal replacement therapies in the treatment of acute renal failure in intensive care patients. I. Theoretical aspects and techniques, Nephrol Dial Transplant, 9, 191 Ronco, 1995, Kontinuierliche nierenersatzverfahren: Wirkungsprinzipien, Dial J, 50, 19 Ronco, 1994, Continuous renal replacement therapies for the treatment of acute renal failure in intensive care patients, Clin Nephrol, 4, 187 Ronco, 1998 De Vries, 1995, Combined measurement of tissue fluid, blood, & hemodynamics in hemodialysis, Int J Artif Organs, 18, 705, 10.1177/039139889501801104 Ronco, 1996, Today's technology for continuous renal replacement therapies, Clin Intensive Care, 7, 198, 10.3109/tcic.7.4.198.205 Bellomo, 1996, Acute renal failure in the intensive care unit: Adequacy of dialysis and the case for continuous therapies, Nephrol Dial Transplant, 11, 424, 10.1093/oxfordjournals.ndt.a027305 Conger, 1994, Response to hemorrhagic arterial pressure reduction in different ischemic renal failure models, Kidney Int, 46, 318, 10.1038/ki.1994.277 Ronco, 1998, Continuous versus intermittent renal replacement therapy in the treatment of acute renal failure, Nephrol Dial Transplant, 13, 79, 10.1093/ndt/13.suppl_6.79 Bellomo, 1996, Nomenclature for continuous renal replacement therapies, Am J Kidney Dis, 28, S2, 10.1016/S0272-6386(96)90073-6 Ronco, 1987, Solute and water transport during continuous arterio-venous hemofiltration, Int J Artif Organs, 10, 179, 10.1177/039139888701000309 Silvester, 1998, Outcome studies of continuous renal replacement therapy in the intensive care unit, Kidney Int, 53, S138 Depner, 1994, Assessing adequacy of hemodialysis: Urea modeling, Kidney Int, 45, 1522, 10.1038/ki.1994.199 Santoro, 1995, On-line monitoring, Nephrol Dial Transplant, 10, 615 Garred, 1993, Urea kinetic modelling with a prototype urea sensor in the spent dialysate stream, ASAIO J, 39, M337 Lindsay, 1993, On-line urea kinetic modeling: Preliminary results, Nephrol Dial Transplant, 8, 995 Keshaviah, 1994, A new approach to dialysis quantification: An adequacy index based on solute removal, Semin Dial, 7, 85, 10.1111/j.1525-139X.1994.tb00814.x Depner, 1991 Pedrini, 1988, Causes, kinetics and clinical implications of post-hemodialysis urea rebound, Kidney Int, 24, 817, 10.1038/ki.1988.255 Thomaseth, 1994, PANSYM: A symbolic equation generation for mathematical modeling, analysis and control of metabolic and pharmacokinetic systems, Comput Methods Programs Biomed, 42, 99, 10.1016/0169-2607(94)90046-9 Thavarungkul, 1991, Continuous monitoring of urea in blood during dialysis, Biosens Bioelectron, 6, 323, 10.1016/0956-5663(91)87033-8 Ghezzi, 1983, Theoretical model and first clinical results of the paired filtration dialysis, Life Support Syst, Suppl 1, 271 Levin, 1990, What is the role of Kt/V urea in chronic dialysis, Semin Dial, 3, 73 Jindal, 1987, Percent reduction of the blood urea concentration during hemodialysis (PRU), a simple and accurate method of estimate Kt/V urea, ASAIO Trans, 33, 286 Daugirdas, 1990, Rapid methods of estimating Kt/V: Three formulas compared, ASAIO Trans, 36, M362 Garred, 1994, Optimal hemodialysis: The role of quantification, Semin Dial, 1, 236 Schneditz, 1992, Caridopulmonary recirculation in dialysis: An underrecognized phenomenon, ASAIO J, 38, M194, 10.1097/00002480-199207000-00018 Ronco, 1995, On-line urea monitoring: A further step towards adequate dialysis prescription and delivery, Int J Artif Organs, 9, 534, 10.1177/039139889501800911 Ronco, 1996, Future technology for CRRT, Am J Kidney Dis, 5, 121, 10.1016/S0272-6386(96)90091-8 van der Sande, 1999, Effect of dialysate temperature on energy balance during hemodialysis: Quantification of extracorporeal energy transfer, Am J Kidney Dis, 33, 1115, 10.1016/S0272-6386(99)70149-6 Santoro, 1998, Blood, regulation during hemodialysis, Am J Kidney Dis, 32, 739, 10.1016/S0272-6386(98)70128-3 Ronco, C: Evolution of technology in hemodialysis. Semin Dial (in press)