Experimental studies on smoke movement in a model tunnel with longitudinal ventilation

Tunnelling and Underground Space Technology - Tập 35 - Trang 135-141 - 2013
L. Yi1,2, J.L. Niu1, Z.S. Xu1, D.X. Wu3
1Institute of Disaster Prevention Science and Safety Technology, Central South University, Changsha, Hunan, China
2Key Laboratory of Gas and Fire Prevention of Henan Province, Henan Polytechnic University, Jiaozuo, Henan, China
3Zhejiang Provincial Institute of Communications Planning, Design and Research, Hangzhou, Zhejiang, China

Tài liệu tham khảo

Danziger, N.H., Kennedy, W.D., 1982. Longitudinal ventilation analysis for the Glenwood canyon tunnels. In: Proceedings of the Fourth International Symposium Aerodynamics and Ventilation of Vehicle Tunnels, pp. 169–186. He, 1999, Smoke temperature and velocity decays along corridors, Fire Safety J., 33, 71, 10.1016/S0379-7112(99)00012-0 Hu, 2008, Studies on buoyancy-driven back-layering in tunnel fires, Exp. Therm. Fluid Sci., 32, 1468, 10.1016/j.expthermflusci.2008.03.005 Hu, 2006, On the maximum smoke temperature under ceiling in tunnel fires, Tunn. Undergr. Sp. Technol., 21, 650, 10.1016/j.tust.2005.10.003 Hu, 2007, Experimental studies on fire-induced buoyant smoke temperature distribution along tunnel ceiling, Build Environ., 42, 3905, 10.1016/j.buildenv.2006.10.052 Hu, 2007, Experimental and numerical studies on longitudinal smoke temperature distribution upstream and downstream from the fire in a road tunnel, J. Fire Sci., 25, 23, 10.1177/0734904107062357 Kurioka, 2003, Fire properties in near field of square fire source with longitudinal ventilation in tunnels, Fire Safety J., 38, 319, 10.1016/S0379-7112(02)00089-9 Kunsch, 2002, Simple model for control of fire gases in a ventilated tunnel, Fire Safety J., 37, 67, 10.1016/S0379-7112(01)00020-0 Lee, 2005, An experimental study of the effect of the aspect ratio on the critical velocity in longitudinal ventilation tunnel fires, J. Fire Sci., 23, 119, 10.1177/0734904105044630 Li, 2010, Study of critical velocity and backlayering length in longitudinally ventilated tunnel fires, Fire Safety J., 45, 361, 10.1016/j.firesaf.2010.07.003 Ministry of Transport of PR China, 2000. JTJ 026.1-1999 Specifications for Design of Ventilation and Lighting of Highway Tunnel. NFPA, 2011. NFPA 502 Standard for Road Tunnels, Bridges, and Other Limited Access Highways. Oka, 1995, Control of smoke flow in tunnel fires, Fire Safety J., 25, 305, 10.1016/0379-7112(96)00007-0 Quintiere, 1989, Scaling applications in fire research, Fire Safety J., 15, 3, 10.1016/0379-7112(89)90045-3 Thomas, P.H., 1968. The Movement of Smoke in Horizontal Passages Against an Air Flow. Fire Research Note, No. 723, Fire Research Station, Watford, UK. Vauquelin, 2005, Parametrical study of the back flow occurrence in case of a buoyant release into a rectangular channel, Exp. Therm. Fluid Sci., 29, 725, 10.1016/j.expthermflusci.2005.01.002 Vuilleumier, 2002, Safety aspects of railway and road tunnel: example of the Lotschberg railway tunnel and Mont-Blanc road tunnel, Tunn. Undergr. Sp. Technol., 17, 153, 10.1016/S0886-7798(02)00018-4 Wu, 2000, Control of smoke flow in tunnel fires using longitudinal ventilation systems – a study of the critical velocity, Fire Safety J., 35, 363, 10.1016/S0379-7112(00)00031-X