Defibrillazioni semiautomatica e completamente automatica esterne

EMC - Urgenze - Tập 20 - Trang 1-11 - 2016
J.-M. Agostinucci1, P. Bertrand2
1Samu 93, CHU Avicenne, 125, rue de Stalingrad, 93000 Bobigny, France
2Croix-Rouge française, PSD93, 96, rue Didot, 75014 Paris, France

Tài liệu tham khảo

Valuenzuela, 2000, Outcomes of rapid defibrillation by security officers after cardiac arrest in casinos, N Engl J Med, 343, 1206, 10.1056/NEJM200010263431701 Larsen, 1993, Predicting survival from out-of-hospital cardiac arrest: a graphic model, Ann Emerg Med, 22, 1652, 10.1016/S0196-0644(05)81302-2 Driscol, 1975, The remarkable Dr Abildgaard and countershock. The bicentennial of his electrical experiments on animals, Ann Intern Med, 83, 878, 10.7326/0003-4819-83-6-878 Prévost, 1899, Sur quelques effets des décharges électriques sur le cœur des mammifères, CR Acad Sci, 1269, 167 Hooker, 1933, The effects of alternating electrical currents on the heart, Am J Physiol, 103, 444, 10.1152/ajplegacy.1933.103.2.444 Beck, 1947, Ventricular fibrillation of long duration abolished by electric shock, JAMA, 113, 985, 10.1001/jama.1947.62890150005007a Zoll, 1956, Termination of ventricular fibrillation in man by externally applied countershock, N Engl J Med, 254, 727, 10.1056/NEJM195604192541601 Eisenberg, 1980, Treatment of out-of-hospital cardiac arrets with rapid defibrillation by emergency medical technicians, N Engl J Med, 302, 1379, 10.1056/NEJM198006193022502 Lapandry, 2000, Historique de la défibrillation, Urg Prat, 41, 9 Plaisance, 2005, L’utilisation des défibrillateurs semi-automatiques en France : état des lieux et perspectives en 2005, Reanimation, 14, 707, 10.1016/j.reaurg.2005.10.012 Spaulding, 1997, Immediate coronary angiography in survivors of out-of-hospital cardiac arrest, N Engl J Med, 336, 1629, 10.1056/NEJM199706053362302 Levy, 2000, La mort subite en France, Urg Prat, 41, 27 1997, Overview of defibrillators Kerber, 1984, Advance prediction of transthoracic impedance in human defibrillation and Cardioversion: importance of impedance in determining the success of low energy shocks, Circulation, 70, 303, 10.1161/01.CIR.70.2.303 Cansell, 2004, Impulsions de défibrillation biphasiques : leur influence sur la survie en réanimation préhospitalière, Rev SAMU, 287 Didon, 2008, Clinical experience with a low-energy pulsed biphasic waveform in out-of-hospital cardiac arrest, Resuscitation, 76, 350, 10.1016/j.resuscitation.2007.08.010 Greene, 1995, Comparison of monophasic and biphasic defibrillating uls wareform for transthorac cardioversion, Am J Cardiol, 75, 1135, 10.1016/S0002-9149(99)80745-0 Bardy, 1996, Multicenter comparison of trunated biphasic shocks and standard damped sine weve monophasic shocks for transthoracic ventricular defibrillation. Transthoracic investigators, Circulation, 94, 2507, 10.1161/01.CIR.94.10.2507 Deakin, 2010, European Resuscitation Council Guidelines for Resuscitation 2010 Section 3. Electrical therapies: automated external defibrillators, defibrillation, cardioversion and pacing, Resuscitation, 81, 1293, 10.1016/j.resuscitation.2010.08.008 Schneider, 2000, Multicenter, randomized, controlled trial of 150J biphasicshocks compared with 200 to 360 J monophasic shocks in the resuscitationof out-of-hospital cardiac arrest victims. Optimized Response to Cradiac Arrest (ORCA) Investigators, Circulation, 102, 1780, 10.1161/01.CIR.102.15.1780 Walsh, 2004, Efficacy of distinct energy delivery protocols comparing two biphasic defibrillators for cardiac arrest, Am J Cardiol, 94, 378, 10.1016/j.amjcard.2004.04.042 Monsieurs, 2005, A study comparing the usually or fully automatic vs semi-automatic defibrillation by untrained nursing students, Resuscitation, 64, 41, 10.1016/j.resuscitation.2004.07.003 Lapostolle, 2005, Quality of prehospital CPR based on AED records, Resuscitation, 66, 246, 10.1016/j.resuscitation.2005.02.009 Kerber, 1997, Circulation, 95, 1677, 10.1161/01.CIR.95.6.1677 Young, 1997, What is confidence? Part 2: detailed definition and determination of confidence intervals, Ann Emerg Med, 30, 311, 10.1016/S0196-0644(97)70167-7 Eisenberg, 1990, Cardiac arrest and resuscitation: a tale of 29 cities, Ann Emerg Med, 19, 179, 10.1016/S0196-0644(05)81805-0 Cummins, 1990, Encouraging early defibrillation: the American Heart Association and automated external defibrillators, Ann Emerg Med, 19, 1245, 10.1016/S0196-0644(05)82282-6 Cummins, 1991, Improving survival from sudden cardiac arrest: the “chain of survival” concept. A statement for health professionals from the Advanced Cardiac Life Support Subcommittee and the Emergency Cardiac Care Committee, American Heart Association, Circulation, 83, 1832, 10.1161/01.CIR.83.5.1832 Auble, 1995, Effect of out-of-hospital defibrillation by basic life support providers on cardiac arrest mortality: a meta-analysis, Ann Emerg Med, 25, 642, 10.1016/S0196-0644(95)70178-8 Hargarten, 1990, Prehospital experience with defibrillation of coarse ventricular fibrillation: a ten-year review, Ann Emerg Med, 19, 157, 10.1016/S0196-0644(05)81801-3 Prost, 1993, Utilisation du défibrillateur semi-automatique en milieu extrahospitalier, Rev SAMU, 5–6, 218 Jost, 1998, Expérience française de défibrillation semi-automatique, JEUR, 3, 124 Décret no 98-239 du 27 mars 1998. JORF 1998. Décret no 105 du 4 mai 2007. JORF 2007, texte 56. Arrêté du 3 mars 2006 relatif à l’attestation de formation aux gestes et soins d’urgence. JORF 2006, texte 24. Koster, 2010, Adult basic life support and use of automated external defibrillators, Resuscitation, 81, 1277, 10.1016/j.resuscitation.2010.08.009 Ettelt, 2006, Evidence-based policy? The use of mobile phones in hospital, J Public Health, 28, 299, 10.1093/pubmed/fdl067 Deakina, 2010, Adult advanced life support, Resuscitation, 81, 1305 Rodríguez-Núñez, 2014, Shockable rhythms and defibrillation during in-hospital pediatric cardiac arrest, Resuscitation, 85, 387, 10.1016/j.resuscitation.2013.11.015 Biarent, 2010, Paediatric life support, Resuscitation, 81, 1364, 10.1016/j.resuscitation.2010.08.012 Divekar, 2006, Successful parental use of an automated external defibrillator for an infant with long-QT syndrome, Pediatrics, 118, e526, 10.1542/peds.2006-0129 Direction générale de la sécurité civile et de la gestion des crises, Recommandations relative à l’unité d’enseignement. Prévention et Secours Civique de Niveau 1, 1er juillet 2012. Tromp, 2011, Electrical cardioversion during pregnancy: safe or not?, Neth Heart J, 19, 134, 10.1007/s12471-011-0077-5 Adamson, 2007, Managing palpitations and arrhythmias during pregnancy, Heart, 93, 1630 Jeejeebhoy, 2013, Maternal cardiac arrest: a practical and comprehensive review, Emerg Med Int, 2013, 274814, 10.1155/2013/274814 Petitot JC, Andrivet P, Blond S, Crespon C, Dormont P, Franck R, et al. Interactions entre dispositifs médicaux implantables actifs et dispositifs médicaux. AFSSAPS; 2005. Pommergaard, 2013, Use of mobile phones in hospitals do not jeopardise the safety of the patients, Ugeskr Laeger, 175, 876 Kanz, 2004, Effect of digital cellular phones on tachyarrhythmia analysis of automated external defibrillators, Eur J Emerg Med, 11, 75, 10.1097/00063110-200404000-00004 Trigano, 2006, Clinical testing of cellular phone ringing interference with automated external defibrillators, Resuscitation, 71, 391, 10.1016/j.resuscitation.2006.04.013 Application pour Smartphone. Pocket CPR. Zoll médical 2014. Leclercq G. Sécurité de la défibrillation automatisée externe. Conseil français de réanimation cardio-pulmonaire, 5e forum de l’urgence. Lyon. 26–27 novembre 2008. Décret n°2011-968 du 16 août 2011 – art. 1. Relatif à la revente des dispositifs médicaux d’occasion. JORF 2011;no 0190:14001. Jost, 1999, Incident survenu au cours de l’utilisation des défibrillateurs semi-automatiques dans les arrêts cardio-respiratoires préhospitaliers, Ann Fr Anesth Reanim, 18, R483 Bertrand, 2004, Preliminary report on AED deployment on the entire Air France commercial fleet: a joint venture with Paris XII University Training Programme, Resuscitation, 63, 175, 10.1016/j.resuscitation.2004.05.011 Hallstrom, 2004, Public-access defibrillation and survival after out-of-hospital cardiac arrest, N Engl J Med, 351, 637, 10.1056/NEJMoa040566 Caffrey, 2002, Public use of automated external defibrillators, N Engl J Med, 347, 1242, 10.1056/NEJMoa020932 Riffler, 2006, DEA pour le public, DSA pour les secouristes, Rev SAMU, 28, 261 Bardy, 2008, Home use of automated external defibrillators for sudden cardiac arrest, N Engl J Med, 358, 1793, 10.1056/NEJMoa0801651 Recommandations pour l’organisation de programmes de défibrillation automatisée externe par le public. http://www.cfrc.fr/documents/recommandations_defibrillation_cfrc_2008.pdf. Arrêté 16 août 2010 fixant les modalités de signalisation des défibrillateurs cardiaques automatisés externes dans les lieux publics. JORF 2010, texte 48. Application pour Smartphone. Arrêt cardiaque 2. Association RMC-BFM-EFHE. Conférence d’experts Société française d’anesthésie et de réanimation et de la Société francophone de médecine d’urgence sur la prise en charge des urgences vitales intrahospitalières, 2004. Lloyd, 2008, Hands-on defibrillation: an analysis of electrical current flow through rescuers in direct contact with patients during biphasic external defibrillation, Circulation, 117, 2510, 10.1161/CIRCULATIONAHA.107.763011 Tucker, 1991, Do surgical gloves protect staff during electrosurgical procedures?, Surgery, 110, 892 Sullivan, 2008, Letter by Sullivan regarding article. Hands-on defibrillation: an analysis of electrical current flow through rescuers in direct contact with patients during biphasic external defibrillation, Circulation, 118, e712, 10.1161/CIRCULATIONAHA.108.803718