Development and evaluation of a reverse transcription loop-mediated isothermal amplification assay for rapid detection of a new SFTS bunyavirus
Tóm tắt
The etiological agent of severe fever with thrombocytopenia syndrome (SFTS) is a bunyavirus that was first identified in China in 2009. We have developed and validated a one-step, single-tube, reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay for detection of SFTS bunyavirus (SFTSV). This assay demonstrated high specificity and sensitivity, with a detection limit of 101 TCID50 ml−1. When combined with the fluorescent detection reagent (FDR) method, results could be determined by observing a color change within 30 min. As an accurate, rapid, simple and low-cost diagnostic method, this RT-LAMP assay will be helpful for detecting and preventing further SFTSV infection in China.
Tài liệu tham khảo
Yu XJ, Liang MF, Zhang SY, Liu Y, Li JD, Sun YL, Zhang L, Popov VL, Li DX et al (2011) Fever with thrombocytopenia associated with a novel bunyavirus in China. N Engl J Med 364:1523–1532
Zhang YZ, Zhou DJ, Xiong Y, Chen XP, He YW, Sun Q, Wang Y, de Jong MD, Xu J et al (2011) Hemorrhagic fever caused by a novel tick-borne Bunyavirus in Huaiyangshan China. Zhonghua Liu Xing Bing Xue Za Zhi 32:209–220
Stone R (2010) Rival teams identify a virus behind deaths in central China. Science 330:20–21
Li DX (2011) Fever with thrombocytopenia associated with a novel bunyavirus in China. Zhonghua Shi Yan He Lin Chuang Bing Du Xue Za Zhi 25:81–84
Notomi T, Okayama H, Masubuchi H, Yonekawa T, Watanabe K, Amino N, Hase T (2000) Loop-mediated isothermal amplification of DNA. Nucleic Acids Res 28:1–7
Tomita N, Mori Y, Kanda H, Notomi T (2008) Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products. Nat Protoc 3:877–882
Nagamine K, Hase T, Notomi T (2002) Accelerated reaction by loop-mediated isothermal amplification using loop primers. Mol Cell Probes 16:223–229
Fukuta S, Iida T, Mizukami Y, Ishida A, Ueda J, Kanbe M, Ishimoto Y (2003) Detection of Japanese yam mosaic virus by RT-LAMP. Arch Virol 148:1713–1720
Ma XJ, Shu YL, Nie K, Qin M, Wang DY, Gao RB, Wang M, Wen LY, Han F, Zhou SM, Zhao X, Cheng YH, Li DX, Dong XP (2010) Visual detection of pandemic influenza A H1N1 Virus 2009 by reverse-transcription loop-mediated isothermal amplification with hydroxynaphthol blue dye. J Virol Methods 167:214–217
Tao J, Juan L, Yongqiang D, Lijuan X, Xiaofeng L, Han J, Cao RY, Qin ED, Qin CF (2011) Development and evaluation of a reverse transcription-loop-mediated isothermal amplification assay for rapid detection of enterovirus 71. J Clin Microbiol 49:870–874
Parida M, Posadas G, Inoue S, Hasebe F, Morita K (2004) Real-time reverse transcription loop-mediated isothermal amplification for rapid detection of West Nile virus. J Clin Microbiol 42:257–263
Kurosaki Y, Takada A, Ebihara H, Grolla A, Kamo N, Feldmann H, Kawaoka Y, Yasuda J (2007) Rapid and simple detection of Ebola virus by reverse transcription-loop-mediated isothermal amplification. J Virol Methods 141:78–83
Sun Y, Liang M, Qu J, Jin C, Zhang Q, Li J, Jiang X, Wang Q, Lu J, Gu W, Zhang S, Li C, Wang X, Zhan F, Yao W, Bi Z, Wang S, Li D (2011) Early diagnosis of novel SFTS bunyavirus infection by quantitative real-time RT-PCR assay. J Clin Virol. doi:10.1016/j.jcv.2011.09.031
Larkin MA, Blackshields G, Brown NP, Chenna R, McGettigan PA, McWilliam H, Valentin F, Wallace IM, Wilm A, Lopez R, Thompson JD, Gibson TJ, Higgins DG (2007) Clustal W and Clustal X version 2.0. Bioinformatics 23:2947–2948
Peyrefitte CN, Boubis L, Coudrier D, Bouloy M, Grandadam M, Tolou HJ, Plumet S (2008) Real-time reverse-transcription loop-mediated isothermal amplification for rapid detection of rift valley fever virus. J Clin Microbiol 46:3653–3659
Pyrc K, Milewska A, Potempa J (2011) Development of loop-mediated isothermal amplification assay for detection of human coronavirus-NL63. J Virol Methods 175:133–136