Can a total knee replacement prosthesis be made entirely of polymers?

Journal of Arthroplasty - Tập 13 - Trang 388-395 - 1998
D.J. Moore1, M.A.R. Freeman2, P.A. Revell3, G.W. Bradley4, M. Tuke5
1The Royal London Hospital, London, England
2Bone and Joint Research Unit, The Royal London Hospital Medical College, London, England
3Department of Histopathology, Royal Free Hospital School of Medicine, London, England
4Santa Barbara, California USA
5Finsbury Instruments, Surrey, England

Tài liệu tham khảo

Freeman, 1978, ICLH Arthroplasty of the knee: 1968–1977, J Bone Joint Surg [Br], 60, 339, 10.1302/0301-620X.60B3.681410 Day, 1979, A method of obtaining immediate, direct fixation of polyethylene to cancellous bone, Trans Orthop Res Soc, 4, 223 1988, 70, 517 Swanson, 1973, Some biological properties of the wear particles generated by all cobalt-chrome total joint prostheses, J Bone Joint Surg [Br], 55, 424 McKellop, 1985, Superior wear properties of an all-polymer hip prosthesis, Trans Orthop Res Soc, 10, 322 McKellop, 1993, Evaluation of wear in an all polymer total knee replacement. Part 1: Laboratory testing of polyethylene on polyacetal bearing surfaces. Part 2: Clinical evaluation of wear in a polyethylene on polyacetal total knee, Clin Mat, 14, 127, 10.1016/0267-6605(93)90033-4 Albrektsson, 1990, The effect of a stem on the tibial component of knee arthroplasty: a roentgen stereophotogrammetric study of uncemented tibial components in the Freeman-Samuelson arthroplasty, J Bone Joint Surg [Br], 72, 252, 10.1302/0301-620X.72B2.2312565 Albrektsson, 1992, Proximally cemented versus uncemented Freeman-Samuelson knee arthroplasty: a prospective randomised study, J Bone Joint Surg [Br], 74, 233, 10.1302/0301-620X.74B2.1544959 Grewal, 1992, Early migration of prostheses related to long term survivorship: comparison of tibial components in knee replacement, J Bone Joint Surg [Br], 74, 239, 10.1302/0301-620X.74B2.1544960 Mintzer, 1990, Bone loss in the distal anterior femur after total knee arthroplasty, Clin Orthop, 260, 135, 10.1097/00003086-199011000-00024 Van Lenthe, 1997, Stress shielding after total knee replacement may cause bone resorption in the distal femur, J Bone Joint Surg [Br], 79, 117, 10.1302/0301-620X.79B1.6808 Plante-Bordeneuve, 1993, Tibial high-density polyethylene wear in conforming tibiofemoral prosthesis, J Bone Joint Surg [Br], 75, 630, 10.1302/0301-620X.75B4.8331121 Bradley, 1992, All-polymer total knee replacement, Am J Knee Surg, 5, 3 Freeman, 1985, The management of infected total knee replacements, J Bone Joint Surg [Br], 67, 764, 10.1302/0301-620X.67B5.4055878 Murray, 1993, Survival analysis of joint replacements, J Bone Joint Surg [Br], 75, 697, 10.1302/0301-620X.75B5.8376423 O'Shea, 1992, A simple optical method for the differentiation of two types of polymeric wear debris in tissue samples, J Mater Sci Mater Med, 3, 391, 10.1007/BF00701233