Design and evaluation of a nanometer aerosol differential mobility analyzer (Nano-DMA)

Journal of Aerosol Science - Tập 29 - Trang 497-509 - 1998
D.-R Chen1, D.Y.H Pui1, D Hummes2, H Fissan2, F.R Quant3, G.J Sem3
1Particle Technology Laboratory, Mechanical Engineering Department University of Minnesota, Minneapolis, MN 55455, USA
2Prozess- und Aerosolmesstechnik, Gerhard Mercator Universitaet, Bismarckstr. 81, D-47048 Duisburg, Germany
3TSI Inc., P.O. Box 64394, St. Paul, MN 55164, USA

Tài liệu tham khảo

Birmili, 1997, Determination of differential mobility analyzer transfer function using identical instruments in series, Aerosol Sci. Technol., 27, 215, 10.1080/02786829708965468 Chen, 1997, Numerical modeling of the performance of differential mobility analyzers for nanometer aerosol measurements, J. Aerosol Sci., 28, 985, 10.1016/S0021-8502(97)00004-9 Fissan, 1996, Experimental comparison of four differential mobility analyzers for nanometer aerosol measurements, Aerosol Sci. Technol., 24, 1, 10.1080/02786829608965347 Fissan, H., Hummes, D., Stratmann, F., Neumann, S., Pui, D. Y. H. and Chen, D. (1995) Comparison of four differential mobility analyzers for nanometer aerosol measurement: transfer function evaluation. Proc. PARTEC 95, 21–23 March 1995, 6th European Symp. on Particle Characterization, pp. 391–400. Hummes, 1996, Experimental determination of the transfer function of a differential mobility analyzer (DMA) in the nanometer size range, Part. Part. Syst. Charact., 5, 327, 10.1002/ppsc.19960130513 Kousaka, 1986, Effect of Brownian diffusion on electrical classification of ultrafine aerosol particles in differential mobility analyzer, J. Chem. Eng. Japan, 19, 401, 10.1252/jcej.19.401 Liu, 1974, A submicron aerosol standard and the primary absolute calibration of the condensation nuclei counter, J. Colloid Interface Sci., 47, 155, 10.1016/0021-9797(74)90090-3 Mesbah, B. (1994) Le spectromètre de mobilite electriqué circulair; Performance et applications, These de Doctorat à l’Université Paris XII, 4 Juil., Creteil, France. Mulholland, G. W., Fernandez, M., Chen, D.-R. and Pui, D. Y. H. (1997) Design and testing of an aerosol/sheath inlet for high resolution measurements with the DMA. Presented at the 16th Annual Conf. of the American Association for Aerosol Research (AAAR’97), October13–17, Denver, Colorado. Pourprix, 1990, Electrostatic precipitation of aerosols on wafers, a new mobility spectrometer, 2 Pourprix, M. (1994) Sélecteur de particules chargées, a haute sensibilité. Brevet francais No.94 06273, 24 Mal. Pui, 1997, Guest Editorial—Nanometer particles, J. Aerosol Sci., 28, 539, 10.1016/S0021-8502(96)00495-8 Stratmann, 1997, Differential electrical mobility analysis, Aerosol Sci. Technol., 26, 368, 10.1080/02786829708965437 Winkelmayr, 1991, A new electromobility spectrometer for the measurement of aerosol size distribution in the size range from 1 to 1000 nm, J. Aerosol Sci., 22, 289, 10.1016/S0021-8502(05)80007-2 Zhang, 1995, Radial differential mobility analyzer, Aerosol Sci. Technol., 23, 357, 10.1080/02786829508965320