The Footprints of Electrocardiographic Interference: Fact or Artefact

Heart, Lung and Circulation - Tập 28 - Trang 1472-1483 - 2019
Harry G. Mond1,2, Haris M. Haqqani3
1Department of Cardiology, The Royal Melbourne Hospital, and University of Melbourne, Melbourne, Vic, Australia
2Cardioscan Pty Ltd., Melbourne, Vic, Australia
3Department of Cardiology, The Prince Charles Hospital and Faculty of Medicine, University of Queensland, Brisbane, Qld, Australia

Tài liệu tham khảo

Mond, 2016, Twisted leads: the footprints of malpositioned electrocardiographic leads, Heart Lung Circ, 25, 61, 10.1016/j.hlc.2015.05.010 Buendia-Fuentes, 2012, High-bandpass filters in electrocardiography: source of error in the interpretation of the ST segment, ISRN Cardiol, 10.5402/2012/706217 Bailey, 1990, Recommendations for standardization and specifications in automated electrocardiography: bandwidth and digital signal processing, Circulation, 81, 730, 10.1161/01.CIR.81.2.730 Lee, 2005, Design of an adaptive filter with a dynamic structure for ECG signal processing, Int J Control Autom Syst, 3, 137 Imtiaz, 2016, ECG artefact identification and removal in mHealth systems for continuous patient monitoring, Healthc Technol Lett, 3, 171, 10.1049/htl.2016.0020 Mond, 2017, The spectrum of ambulatory electrocardiographic monitoring, Heart Lung Circ, 26, 1160, 10.1016/j.hlc.2017.02.034 Mond, 2017, The electrocardiographic footprints of Wenckebach block, Heart Lung Circ, 26, 1252, 10.1016/j.hlc.2017.06.718 Matthias, 2014, Electrocardiogram artefact caused by rigors mimicking narrow complex tachycardia: a case report, BMC Res Notes, 7, 80, 10.1186/1756-0500-7-80 Huang, 2006, An accurate electrocardiographic algorithm for differentiation of tremor-induced pseudo-ventricular tachycardia and true ventricular tachycardia, Int J Cardiol, 111, 163, 10.1016/j.ijcard.2005.06.017 Sevenson, 2001, Electrocardiography artefact: what you do not know, you do not recognise, Am J Med, 110, 402, 10.1016/S0002-9343(01)00637-4 Knight, 1999, Clinical consequences of electrocardiographic artefact mimicking ventricular tachycardia, N Engl J Med, 341, 1270, 10.1056/NEJM199910213411704 Knight, 2001, Physician interpretation of electrocardiographic artefact that mimics ventricular tachycardia, Am J Med, 110, 335, 10.1016/S0002-9343(01)00627-1 Massel, 2000, Strict reliance on a computer algorithm for measurable ST segment criteria may lead to errors in thrombolytic therapy eligibility, Am Heart J, 140, 221, 10.1067/mhj.2000.108240 Rudiger, 2003, Influence of electrode misplacement on the electrocardiographic signs of inferior myocardial ischaemia, Am J Emerg Med, 21, 574, 10.1016/j.ajem.2003.08.007 Aslager, 2012, Electromechanical association: a subtle electrocardiogram artifact, J Electrocardiol, 45, 15, 10.1016/j.jelectrocard.2010.12.162 Mond, 2014, The cardiac implantable electronic device power source: evolution and revolution, Pacing Clin Electrophysiol, 37, 1728, 10.1111/pace.12526 Ortega, 2005, Runaway pacemaker: a forgotten phenomenon?, Europace, 7, 592, 10.1016/j.eupc.2005.06.004 Mond, 1988, Rate responsive pacing using a minute ventilation sensor, Pacing Clin Electrophysiol, 11, 1866, 10.1111/j.1540-8159.1988.tb06322.x Biotronik products. Closed loop stimulation. https://www.biotronik.com/en-us/products/services/cls.