Design and characterization of a tissue-equivalent CVD-diamond detector for clinical dosimetry in high-energy photon beams

Physica Medica - Tập 24 - Trang 159-168 - 2008
B. Górka1, B. Nilsson1, R. Svensson1, A. Brahme1, P. Ascarelli2, D.M. Trucchi2, G. Conte3, R. Kalish4
1Medical Radiation Physics, Department of Oncology and Pathology, Karolinska Institutet and Stockholm University, Box 260, 171 76 Stockholm, Sweden
2Istituto dei Sistemi Complessi, National Research Council, Via Salaria km 29.300 Monterotondo Scalo, 00016 Rome, Italy
3Department of Electronic Engineering, University of Rome “Roma Tre”, Via della Vasca Navale 84, 00146 Rome, Italy
4Physics Department and Solid State Institute, Technion, Haifa 32000, Israel

Tài liệu tham khảo

Svensson, 1986, Recent advances in electron and photon dosimetry, 87 Burgemeister, 1981, Dosimetry with a diamond operating as a resistor, Phys Med Biol, 26, 269, 10.1088/0031-9155/26/2/006 Manfredotti, 1998, CVD diamond tips as x-ray detectors, Diamond Relat Mater, 7, 523, 10.1016/S0925-9635(97)00275-6 ICRU, 1984 ICRU, 1989 White DR. Tissue substitutes in experimental radiation physics. Med Phys 197;5:467–79. Vatnitsky, 1993, Application of a natural diamond detector for the measurements of relative dose distributions in radiotherapy, Phys Med Biol, 38, 173, 10.1088/0031-9155/38/1/013 Rustgi, 1995, Evaluation of the dosimetric characteristics of a diamond detector for photon beam measurements, Med Phys, 22, 567, 10.1118/1.597543 Heydarian, 1996, A comparison of dosimetry techniques in stereotactic radiosurgery, Phys Med Biol, 41, 93, 10.1088/0031-9155/41/1/008 Laub, 1999, A diamond detector in the dosimetry of high-energy electron and photon beams, Phys Med Biol, 44, 2183, 10.1088/0031-9155/44/9/306 De Angelis, 2002, An investigation of the operating characteristics of two PTW diamond detectors in photon and electron beams, Med Phys, 29, 248, 10.1118/1.1446101 Bucciolini, 2003, Diamond detector versus silicon diode and ion chamber in photon beams of different energy and field size, Med Phys, 30, 2149, 10.1118/1.1591431 Bacci, 1997, Correlation between material properties and leakage current in CVD diamond films deposited by DC plasma glow discharge, Mat Sci Eng B, 47, 54, 10.1016/S0921-5107(97)00002-0 Meier, 1999 Oh, 1999 Ascarelli, 2003, CVD diamond dosimetric response evaluated by X-ray absorbers method, Diamond Relat Mater, 12, 691, 10.1016/S0925-9635(02)00375-8 Buttar, 1997, CVD diamond detectors as dosimeters for radiotherapy, Nucl Instrum Meth A, 392, 281, 10.1016/S0168-9002(97)00296-9 Ramkumar, 2001, An assessment of radiotherapy dosimeters based on CVD grown diamond, Nucl Instrum Meth A, 460, 401, 10.1016/S0168-9002(00)01062-7 Bucciolini, 2005, Diamond dosimetry: outcomes of the CANDIDO and CONRAD INFN projects, Nucl Instrum Meth A, 552, 189, 10.1016/j.nima.2005.06.030 Fidanzio, 2004, Photon and electron beam dosimetry with a CVD diamond detector, Nucl Instrum Meth A, 524, 115, 10.1016/j.nima.2004.01.056 Fidanzio, 2005, A preliminary dosimetric characterization of chemical vapor deposition diamond detector prototypes in photon and electron radiotherapy beams, Med Phys, 32, 389, 10.1118/1.1851887 De Angelis, 2007, Present limitations of CVD diamond detectors for IMRT applications, Nucl Instrum Meth A, 583, 195, 10.1016/j.nima.2007.08.186 Burgemeister, 1983, The construction of a diamond detector for ionising radiation, Radiat Prot Dosimetry, 6, 145, 10.1093/oxfordjournals.rpd.a082889 Marczewska, 2001, Studies on the application of CVD diamonds as active detectors of ionising radiation, Physica B, 308-310, 1213, 10.1016/S0921-4526(01)00945-0 Assiamah, 2007, A synthetic diamond probe for low-energy X-ray dose measurements, Appl Radiat Isot, 65, 545, 10.1016/j.apradiso.2006.11.009 Conte, 2003, Grain boundary transport in x-ray irradiated polycrystalline diamond, J Appl Phys, 93, 6078, 10.1063/1.1565191 Górka, 2006, Influence of electrodes on the photon energy deposition in CVD-diamond dosimeters studied with the Monte Carlo code PENELOPE, Phys Med Biol, 51, 3607, 10.1088/0031-9155/51/15/001 Fowler, 1966, Solid state electrical conductivity dosimeters, 291 McKerracher, 2006, Notes on the construction of solid-state detectors, Radiother Oncol, 79, 348, 10.1016/j.radonc.2006.05.008 Wickman, 1972, Small gas-tight ionization chambers for absorbed dose control during radiation therapy, Acta Radiol, 313, 152, 10.3109/05678067209176142 Wickman, 1992, The use of liquids in ionization chambers for high precision radiotherapy dosimetry, Phys Med Biol, 37, 1789, 10.1088/0031-9155/37/9/005 Andreo, 2000 Hoban, 1994, Dose rate dependence of a PTW diamond detector in the dosimetry of a 6MV photon beam, Phys Med Biol, 39, 1219, 10.1088/0031-9155/39/8/003 Górka B, Fernández-Varea JM, Panettieri V, Nilsson B. Optimization of a tissue-equivalent CVD-diamond dosimeter for radiotherapy using the Monte Carlo code PENELOPE. Submitted for publication.