Improving follow-up of abnormal cancer screens using electronic health records: trust but verify test result communication

BMC Medical Informatics and Decision Making - Tập 9 - Trang 1-7 - 2009
Hardeep Singh1,2, Lindsey Wilson1, Laura A Petersen1,2, Mona K Sawhney1, Brian Reis1, Donna Espadas1, Dean F Sittig3
1The Center of Inquiry to Improve Outpatient Safety Through Effective Electronic Communication and the Houston VA HSR&D Center of Excellence at the Michael E DeBakey Veterans Affairs Medical Center, Houston, USA
2Section of Health Services Research, Department of Medicine, Baylor College of Medicine, Michael E DeBakey Veterans Affairs Medical Center (MEDVAMC), Houston, USA
3The Center of Inquiry to Improve Outpatient Safety Through Effective Electronic Communication, University of Texas School of Health Information Sciences and the UT-Memorial Hermann Center for Healthcare Quality & Safety, Houston, USA

Tóm tắt

Early detection of colorectal cancer through timely follow-up of positive Fecal Occult Blood Tests (FOBTs) remains a challenge. In our previous work, we found 40% of positive FOBT results eligible for colonoscopy had no documented response by a treating clinician at two weeks despite procedures for electronic result notification. We determined if technical and/or workflow-related aspects of automated communication in the electronic health record could lead to the lack of response. Using both qualitative and quantitative methods, we evaluated positive FOBT communication in the electronic health record of a large, urban facility between May 2008 and March 2009. We identified the source of test result communication breakdown, and developed an intervention to fix the problem. Explicit medical record reviews measured timely follow-up (defined as response within 30 days of positive FOBT) pre- and post-intervention. Data from 11 interviews and tracking information from 490 FOBT alerts revealed that the software intended to alert primary care practitioners (PCPs) of positive FOBT results was not configured correctly and over a third of positive FOBTs were not transmitted to PCPs. Upon correction of the technical problem, lack of timely follow-up decreased immediately from 29.9% to 5.4% (p < 0.01) and was sustained at month 4 following the intervention. Electronic communication of positive FOBT results should be monitored to avoid limiting colorectal cancer screening benefits. Robust quality assurance and oversight systems are needed to achieve this. Our methods may be useful for others seeking to improve follow-up of FOBTs in their systems.

Tài liệu tham khảo

Yabroff K, Washington KS, Leader A, Neilson E, Mandelblatt J: Is the Promise of Cancer-Screening Programs Being Compromised? Quality of Follow-Up Care after Abnormal Screening Results. Med Care Res Rev. 2003, 60: 294-331. 10.1177/1077558703254698. Baig N, Myers RE, Turner BJ: Physician-reported reasons for limited follow-up of patients with a positive fecal occult blood test screening result. The American Journal of Gastroenterology. 2003, 98: 2078-2081. 10.1111/j.1572-0241.2003.07575.x. Levin B, Hess K, Johnson C: Screening for colorectal cancer. A comparison of 3 fecal occult blood tests. Arch Intern Med. 1997, 157: 970-976. 10.1001/archinte.157.9.970. Morris JB, Stellato TA, Guy BB, Gordon NH, Berger NA: A critical analysis of the largest reported mass fecal occult blood screening program in the United States. Am J Surg. 1991, 161: 101-105. 10.1016/0002-9610(91)90368-N. Burack RC, Simon MS, Stano M, George J, Coombs J: Follow-up among women with an abnormal mammogram in an HMO: is it complete, timely, and efficient?. Am J Manag Care. 2000, 6: 1102-1113. Bastani R, Yabroff KR, Myers RE, Glenn B: Interventions to improve follow-up of abnormal findings in cancer screening. Cancer. 2004, 101: 1188-1200. 10.1002/cncr.20506. Mandel JS, Church TR, Bond JH: The effect of fecal occult-blood screening on the incidence of colorectal cancer. N Engl J Med. 2000, 343: 1603-1607. 10.1056/NEJM200011303432203. Mandel JS, Bond JH, Church TR: Reducing mortality from colorectal cancer by screening for fecal occult blood. Minnesota Colon Cancer Control Study. N Engl J Med. 1993, 328: 1365-1371. 10.1056/NEJM199305133281901. Kronborg O, Jorgensen OD, Fenger C, Rasmussen M: Randomized study of biennial screening with a faecal occult blood test: results after nine screening rounds. Scand J Gastroenterol. 2004, 39: 846-851. 10.1080/00365520410003182. Etzioni D, Yano E, Rubenstein L: Measuring the Quality of Colorectal Cancer Screening: The Importance of Follow-Up. Diseases of the Colon & Rectum. 2006, 49: 1002-1010. 10.1007/s10350-006-0533-2. Fisher DA, Jeffreys A, Coffman CJ, Fasanella K: Barriers to full colon evaluation for a positive fecal occult blood test. Cancer Epidemiol Biomarkers Prev. 2006, 15: 1232-1235. 10.1158/1055-9965.EPI-05-0916. Myers RE, Hyslop T, Gerrity M: Physician Intention to Recommend Complete Diagnostic Evaluation in Colorectal Cancer Screening. Cancer Epidemiol Biomarkers Prev. 1999, 8: 587-593. Myers RE, Turner B, Weinberg D: Impact of a physician-oriented intervention on follow-up in colorectal cancer screening. Prev Med. 2004, 38: 375-381. 10.1016/j.ypmed.2003.11.010. Jimbo M, Myers RE, Meyer B: Reasons Patients With a Positive Fecal Occult Blood Test Result Do Not Undergo Complete Diagnostic Evaluation. Ann Fam Med. 2009, 7: 11-16. 10.1370/afm.906. Wahls T: Diagnostic errors and abnormal diagnostic tests lost to follow-up: a source of needless waste and delay to treatment. J Ambul Care Manage. 2007, 30: 338-343. Poon EG, Wang SJ, Gandhi TK, Bates DW, Kuperman GJ: Design and implementation of a comprehensive outpatient Results Manager. J Biomed Inform. 2003, 36: 80-91. 10.1016/S1532-0464(03)00061-3. Singh H, Arora HS, Vij MS, Rao R, Khan M, Petersen LA: Communication outcomes of critical imaging results in a computerized notification system. J Am Med Inform Assoc. 2007, 14: 459-466. 10.1197/jamia.M2280. Singh H, Naik A, Rao R, Petersen L: Reducing Diagnostic Errors Through Effective Communication: Harnessing the Power of Information Technology. Journal of General Internal Medicine. 2008, 23: 489-494. 10.1007/s11606-007-0393-z. Singh H, Kadiyala H, Bhagwath G: Using a multifaceted approach to improve the follow-up of positive fecal occult blood test results. Am J Gastroenterol. 2009, 104: 942-952. 10.1038/ajg.2009.55. Bagian JP, Gosbee J, Lee CZ, Williams L, McKnight SD, Mannos DM: The Veterans Affairs root cause analysis system in action. Jt Comm J Qual Improv. 2002, 28: 531-545. Ash JS, Smith AC, Stavri PZ: Performing subjectivist studies in the qualitative traditions responsive to users. Evaluation Methods in Biomedical Informatics. Edited by: Friedman CP, Wyatt JC. 2006, Springer New York, 267-300. full_text. 2 Koppel R, Wetterneck T, Telles JL, Karsh BT: Workarounds to Barcode Medication Administration Systems: Their Occurrences, Causes, and Threats to Patient Safety. J Am Med Inform Assoc. 2008, 15: 408-423. 10.1197/jamia.M2616. Singh H, Thomas E, Petersen LA: Automated Notification of Laboratory Test Results in an Electronic Health Record: Do Any Safety Concerns Remain?. American Journal of Medicine. Gandhi TK, Kachalia A, Thomas EJ: Missed and delayed diagnoses in the ambulatory setting: A study of closed malpractice claims. Ann Intern Med. 2006, 145: 488-496. Phillips RL, Bartholomew LA, Dovey SM, Fryer GE, Miyoshi TJ, Green LA: Learning from malpractice claims about negligent, adverse events in primary care in the United States. Qual Saf Health Care. 2004, 13: 121-126. 10.1136/qshc.2003.008029. Singh H, Sethi S, Raber M, Petersen LA: Errors in cancer diagnosis: current understanding and future directions. J Clin Oncol. 2007, 25: 5009-5018. 10.1200/JCO.2007.13.2142. Sittig DF, Singh H: Eight Rights of Safe Electronic Health Record Use. JAMA. 2009, 302: 1111-1113. 10.1001/jama.2009.1311. Bates DW, Leape LL: Doing better with critical test results. Jt Comm J Qual Patient Saf. 2005, 31: 66-67. The pre-publication history for this paper can be accessed here:http://www.biomedcentral.com/1472-6947/9/49/prepub