Anatomical relationship of coronary sinus/great cardiac vein and left circumflex coronary artery along mitral annulus in atrial fibrillation before radiofrequency catheter ablation using 320-slice CT

International Journal of Cardiology - Tập 168 - Trang 5174-5181 - 2013
Kohki Nakamura1, Nobusada Funabashi2, Shigeto Naito1, Masae Uehara3, Hiroyuki Takaoka3, Kenichi Kaseno1, Koji Kumagai1, Shigeru Oshima1, Yoshio Kobayashi3
1Division of Cardiology, Gunma Prefectural Cardiovascular Center, 3-12 Kameizumi-machi, Maebashi City, Gunma 371-0004, Japan
2Department of Cardiovascular Science and Medicine, Chiba University Graduate School of Medicine, 1‐8‐1 Inohana, Chuo‐ku, Chiba City, Chiba 260‐8670, Japan
3Department of Cardiovascular Science and Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-ku, Chiba City, Chiba 260-8670, Japan

Tài liệu tham khảo

Haissaguerre, 2000, Electrophysiological breakthroughs from the left atrium to the pulmonary veins, Circulation, 102, 2463, 10.1161/01.CIR.102.20.2463 Ouyang, 2004, Complete isolation of left atrium surrounding the pulmonary veins: new insights from the double-Lasso technique in paroxysmal atrial fibrillation, Circulation, 110, 2090, 10.1161/01.CIR.0000144459.37455.EE Oral, 2002, Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation, Circulation, 105, 1077, 10.1161/hc0902.104712 Oral, 2003, Catheter ablation for paroxysmal atrial fibrillation: segmental pulmonary vein ostial ablation versus left atrial ablation, Circulation, 108, 2355, 10.1161/01.CIR.0000095796.45180.88 Hocini, 2005, Techniques, evaluation, and consequences of linear block at the left atrial roof in paroxysmal atrial fibrillation: a prospective randomized study, Circulation, 112, 3688, 10.1161/CIRCULATIONAHA.105.541052 Gaita, 2005, Linear cryoablation of the left atrium versus pulmonary vein cryoisolation in patients with permanent atrial fibrillation and valvular heart disease: correlation of electroanatomic mapping and long-term clinical results, Circulation, 111, 136, 10.1161/01.CIR.0000151310.00337.FA Jais, 2004, Technique and results of linear ablation at the mitral isthmus, Circulation, 110, 2996, 10.1161/01.CIR.0000146917.75041.58 Willems, 2006, Substrate modification combined with pulmonary vein isolation improves outcome of catheter ablation in patients with persistent atrial fibrillation: a prospective randomized comparison, Eur Heart J, 27, 2871, 10.1093/eurheartj/ehl093 Takahashi, 2005, Acute occlusion of the left circumflex coronary artery during mitral isthmus linear ablation, J Cardiovasc Electrophysiol, 16, 1104, 10.1111/j.1540-8167.2005.50124.x Wong, 2010, Acute occlusion of left circumflex artery following radiofrequency catheter ablation at the mitral isthmus, Europace, 12, 743, 10.1093/europace/eup447 Fayad, 2003, Circumflex artery stenosis induced by intraoperative radiofrequency ablation, Ann Thorac Surg, 76, 1291, 10.1016/S0003-4975(03)00476-4 Hosaka, 2009, Coronary vasospasm triggered ventricular fibrillation delayed after radiofrequency ablation of the right accessory pathway, Europace, 11, 1554, 10.1093/europace/eup219 Choure, 2006, In vivo analysis of the anatomical relationship of coronary sinus to mitral annulus and left circumflex coronary artery using cardiac multidetector computed tomography: implications for percutaneous coronary sinus mitral annuloplasty, J Am Coll Cardiol, 48, 1938, 10.1016/j.jacc.2006.07.043 Tops, 2007, Noninvasive evaluation of coronary sinus anatomy and its relation to the mitral valve annulus: implications for percutaneous mitral annuloplasty, Circulation, 115, 1426, 10.1161/CIRCULATIONAHA.106.677880 Jongbloed, 2005, Noninvasive visualization of the cardiac venous system using multislice computed tomography, J Am Coll Cardiol, 45, 749, 10.1016/j.jacc.2004.11.035 Van de Veire, 2006, Non-invasive visualization of the cardiac venous system in coronary artery disease patients using 64-slice computed tomography, J Am Coll Cardiol, 48, 1832, 10.1016/j.jacc.2006.07.042 Yang, 2009, 64-MDCT coronary angiography of patients with atrial fibrillation: influence of heart rate on image quality and efficacy in evaluation of coronary artery disease, AJR Am J Roentgenol, 193, 795, 10.2214/AJR.08.2012 Uehara, 2011, Quality of coronary arterial 320-slice computed tomography images in subjects with chronic atrial fibrillation compared with normal sinus rhythm, Int J Cardiol, 150, 67, 10.1016/j.ijcard.2010.02.032 Uehara, 2011, Quality of coronary arterial 320-slice computed tomography images compared with 16-slice computed tomography images in subjects with chronic atrial fibrillation, Int J Cardiol, 149, e90, 10.1016/j.ijcard.2010.09.096 Kataoka, 2011, Quantitative evaluation of left atrial volumes and ejection fraction by 320-slice computed tomography in comparison with three- and two-dimensional echocardiography: a single-center retrospective study in 22 subjects, Int J Cardiol, 153, 47, 10.1016/j.ijcard.2010.08.036 Xu, 2011, Diagnostic performance of 320-detector CT coronary angiography in patients with atrial fibrillation: preliminary results, Eur Radiol, 21, 936, 10.1007/s00330-010-1987-0 Nasis, 2010, Diagnostic accuracy of noninvasive coronary angiography with 320-detector row computed tomography, Am J Cardiol, 106, 1429, 10.1016/j.amjcard.2010.06.073 Becker, 2004, Left atrial isthmus: anatomic aspects relevant for linear catheter ablation procedures in humans, J Cardiovasc Electrophysiol, 15, 809, 10.1046/j.1540-8167.2004.03651.x Wittkampf, 2005, Where to draw the mitral isthmus line in catheter ablation of atrial fibrillation: histological analysis, Eur Heart J, 26, 689, 10.1093/eurheartj/ehi095 Chiribiri, 2008, Magnetic resonance cardiac vein imaging: relation to mitral valve annulus and left circumflex coronary artery, JACC Cardiovasc Imaging, 1, 729, 10.1016/j.jcmg.2008.06.009 Chatelain, 1995, Acute coronary occlusion secondary to radiofrequency catheter ablation of a left lateral accessory pathway, Eur Heart J, 16, 859, 10.1093/oxfordjournals.eurheartj.a061007 Paul, 2003, Complete occlusion of the left circumflex coronary artery after radiofrequency catheter ablation in an infant, J Cardiovasc Electrophysiol, 14, 1004, 10.1046/j.1540-8167.2003.02578.x Calkins, 1992, Radiofrequency catheter ablation of accessory atrioventricular connections in 250 patients. Abbreviated therapeutic approach to Wolff–Parkinson–White syndrome, Circulation, 85, 1337, 10.1161/01.CIR.85.4.1337 Schneider, 2009, Incidence of coronary artery injury immediately after catheter ablation for supraventricular tachycardias in infants and children, Heart Rhythm, 6, 461, 10.1016/j.hrthm.2009.01.029 Solomon, 1993, Effect on coronary artery anatomy of radiofrequency catheter ablation of atrial insertion sites of accessory pathways, J Am Coll Cardiol, 21, 1440, 10.1016/0735-1097(93)90321-Q Paul, 1997, Coronary artery involvement early and late after radiofrequency current application in young pigs, Am Heart J, 133, 436, 10.1016/S0002-8703(97)70185-6 Huang, 1988, Short- and long-term effects of transcatheter ablation of the coronary sinus by radiofrequency energy, Circulation, 78, 416, 10.1161/01.CIR.78.2.416 Bokenkamp, 2000, Effects of intracardiac radiofrequency current application on coronary artery vessels in young pigs, J Cardiovasc Electrophysiol, 11, 565, 10.1111/j.1540-8167.2000.tb00010.x Aoyama, 2005, Comparison of cryothermia and radiofrequency current in safety and efficacy of catheter ablation within the canine coronary sinus close to the left circumflex coronary artery, J Cardiovasc Electrophysiol, 16, 1218, 10.1111/j.1540-8167.2005.50126.x Schwartzman, 2001, Cardiac swelling associated with linear radiofrequency ablation in the atrium, J Interv Card Electrophysiol, 5, 159, 10.1023/A:1011477408021 Simmers, 1998, Effects of intracavitary blood flow and electrode-target distance on radiofrequency power required for transient conduction block in a Langendorff-perfused canine model, J Am Coll Cardiol, 31, 231, 10.1016/S0735-1097(97)00435-X Tops, 2005, Fusion of multislice computed tomography imaging with three-dimensional electroanatomic mapping to guide radiofrequency catheter ablation procedures, Heart Rhythm, 2, 1076, 10.1016/j.hrthm.2005.07.019 Kistler, 2006, Validation of three-dimensional cardiac image integration: use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation, J Cardiovasc Electrophysiol, 17, 341, 10.1111/j.1540-8167.2006.00371.x Richmond, 2008, Validation of computed tomography image integration into the EnSite NavX mapping system to perform catheter ablation of atrial fibrillation, J Cardiovasc Electrophysiol, 19, 821, 10.1111/j.1540-8167.2008.01127.x