Physical aspects of a real-time tumor-tracking system for gated radiotherapy

Hiroki Shirato1, Shinichi Shimizu1, Tatsuya Kunieda2, Kei Kitamura1, Marcel van Herk3, Kenji Kagei1, Takeshi Nishioka1,2,3, Seiko Hashimoto1, Katsuhisa Fujita1, Hidefumi Aoyama1, Kazuhiko Tsuchiya1,2,3, Kohsuke Kudo1, Kazuo Miyasaka1
1Department of Radiation Medicine, Hokkaido University School of Medicine, Sapporo, Japan
2Mitsubishi Electronics Company, Ltd., Tokyo, Japan
3Department of Radiotherapy, The Netherlands Cancer Institute (Antoni van Leeuwenhoek Huis), Amsterdam, The Netherlands

Tài liệu tham khảo

Kubo, 1996, Respiration gated radiotherapy treatment, Phys Med Biol, 41, 83, 10.1088/0031-9155/41/1/007 Inada, 1992, Proton irradiation synchronized with respiratory cycle, Nippon Acta Radiol, 52, 1161 Ohara, 1989, Irradiation synchronized with respiration gate, Int J Radiat Oncol Biol Phys, 17, 853, 10.1016/0360-3016(89)90078-3 Balter, 1998, Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging, Int J Radiat Oncol Biol Phys, 41, 939, 10.1016/S0360-3016(98)00130-8 Wong, 1999, The use of active breathing control (ABC) to reduce margin for breathing motion, Int J Radiat Oncol Biol Phys, 44, 911, 10.1016/S0360-3016(99)00056-5 Shimizu, S, Shirato H, Kagei K; et al. Impact of respiratory movement on the computed tomographic images of small lung tumors in three dimensional (3D) radiotherapy. Int J Radiat Oncol Biol Phys 2000:46(5):1127–1133. Shimizu, 1999, Three-dimensional movement of a liver tumor detected by high-speed magnetic resonance imaging, Radiother Oncol, 50, 367, 10.1016/S0167-8140(98)00140-6 Shirato H, Shimizu S, Kitamura K; et al. Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. Int J Radiat Oncol Biol Phys 2000;48:435–442. Shirato, 1999, Real-time tumour-tracking radiotherapy, Lancet, 353, 1331, 10.1016/S0140-6736(99)00700-X Otsu, 1979, A threshold selection method from gray-level histograms, IEEE Trans Syst Man Cybernet, 9, 62, 10.1109/TSMC.1979.4310076 Sumi, 1995, Three-level broad-edge template matching and its application to real-time vision system, IEICE Trans Inf Syst E 78-D, 12, 1526 Coxeter HSM. Projective geometry. 2nd ed. New York: Springer-Verlag; 1987. Shirato, 1997, Stereotactic irradiation without whole-brain irradiation for single brain metastasis, Int J Radiat Oncol Biol Phys, 37, 385, 10.1016/S0360-3016(96)00488-9 Shirato, 1999, Comparison between observation policy and fractionated stereotactic radiotherapy (SRT) as an initial management for vestibular schwannoma, Int J Radiat Oncol Biol Phys, 44, 545, 10.1016/S0360-3016(99)00079-6 van Herk, 1995, Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration, Int J Radiat Oncol Biol Phys, 33, 1311, 10.1016/0360-3016(95)00116-6 Bel, 1996, Target margins for random geometrical treatment uncertainties in conformal radiotherapy, Med Phys, 23, 1537, 10.1118/1.597745 Mageras, 1999, Computerized design of target margins for treatment uncertainties in conformal radiotherapy, Int J Radiat Oncol Biol Phys, 15, 437, 10.1016/S0360-3016(98)00386-1 Low, 1997, The influence of angular misalignment on fixed-portal intensity modulated radiation therapy, Med Phys, 24, 1123, 10.1118/1.598015 Nakagawa, 1994, Real-time beam monitoring in dynamic conformation therapy, Int J Radiat Oncol Biol Phys, 30, 1233, 10.1016/0360-3016(94)90334-4 Uematsu, 1996, A dual computed tomography linear accelerator unit for stereotactic radiation therapy, Int J Radiat Oncol Biol Phys, 35, 587, 10.1016/S0360-3016(96)80022-8 Jaffray, 1999, A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets, Int J Radiat Oncol Biol Phys, 45, 773, 10.1016/S0360-3016(99)00118-2 Crook, 1995, Prostate motion during standard radiotherapy as assessed by fiducial markers, Radiother Oncol, 37, 35, 10.1016/0167-8140(95)01613-L Ramsey, 1999, A comparison of beam characteristics for gated and nongated clinical x-ray beams, Med Phys, 26, 2086, 10.1118/1.598723 Bova, 1997, The University of Florida frameless high-precision stereotactic radiotherapy system, Int J Radiat Oncol Biol Phys, 38, 875, 10.1016/S0360-3016(97)00055-2 Rogus, 1999, Accuracy of a photogrammetry-based patient positioning and monitoring system for radiation therapy, Med Phys, 26, 721, 10.1118/1.598578 Seiler PG, Blattmann H, Kirsh S; et al. A novel tracking technique for the continuous precise measurement of tumour positions in conformal radiotherapy. Phys Med Biol 2000;45. In press.