Head-to-head comparison of exercise stress testing, pharmacologic stress echocardiography, and perfusion tomography as first-line examination for chest pain in patients without history of coronary artery disease

Journal of Nuclear Cardiology - Tập 5 - Trang 19-27 - 1998
Giovanni M. Santoro1,2, Roberto Sciagrà1,2, Piergiovanni Buonamici1,2, Nicola Consoli1,2, Vincenzo Mazzoni1,2, Francesca Zerauschek1,2, Gianni Bisi1,2, Pier Filippo Fazzini1,2
1Division of Cardiology, Careggi Hospital, Firenze, Italy
2Nuclear Medicine Unit, Department of Clinical Pathophysiology, University of Florence, Florence, Italy

Tóm tắt

To overcome the relatively low accuracy of exercise stress testing (EST) in detecting coronary artery disease (CAD), both echocardiography and perfusion scintigraphy have been evaluated in conjunction with pharmacologic stress, but there is still uncertainty of the relative value of these tests as possible first-line examinations for suspected CAD. This study evaluated the accuracy of EST, dipyridamole and dobutamine stress echocardiography (DIP-ECHO, DOB-ECHO), and dipyridamole and dobutamine technetium 99m sestamibi tomography (DIP-MIBI, DOB-MIBI) for the detection of CAD in patients evaluated for the first time because of chest pain. Sixty patients underwent EST, DIP-ECHO, DOB-ECHO, DIP-MIBI, and DOB-MIBI. Echocardiographic images were acquired simultaneously with sestamibi injections, and the scintigraphic images were collected 1 hour later. Coronary angiography was performed within 15 days. Out of 33 patients with significant (>70%) coronary stenoses, 19 (58%) were correctly identified by EST, 18 (55%) by DIP-ECHO, 20 (61%) by DOB-ECHO, 32 (97%) by DIP-MIBI, and 30 (91%) by DOB-MIBI (p<0.005 for MIBI vs EST and ECHO). The specificity of EST was 67% (p<0.05 vs ECHO and MIBI), 96%, 96%, 89%, and 81%, respectively. Of the 62 stenotic coronary arteries, 20 (32%) were correctly identified by DIP-ECHO, 24 (39%) by DOB-ECHO, 48 (77%) by DIP-MIBI, and 45 (73%) by DOB-MIBI. The sensitivity of the imaging techniques in predicting the presence of multivessel disease was 14% and 29% for DIP and DOB-ECHO compared with 48% and 57% for DIP and DOB-MIBI. Our results confirm the limited reliability of EST in detecting CAD and the good diagnostic value of DIP and DOB-MIBI. Conversely, the lower sensitivity and the poorer capability to recognize multivessel CAD do not support the role of either DIP or DOB-ECHO as first-line examination for suspected CAD.

Tài liệu tham khảo

Picano E, Distante A, Masini M, Morales MA, Lattanzi F, L'Abbate A. Dypiridamole-echocardiography test in effort angina pectoris. Am J Cardiol 1985;56:452–6. Picano E, Simonetti I, Masini M, et al. Transient myocardial dysfunction during pharmacologic vasodilatation as an index of reduced coronary reserve: a coronary hemodynamic and echocardiographic study. J Am Coll Cardiol 1986;8:84–90. Cohen JL, Greene TO, Alston JR, Wilchfort SD, Kim CS. Usefulness of oral dipyridamole digital echocardiography for detecting coronary artery disease. Am J Cardiol 1989;64:385–6. Mazeika P, Nihoyannopoulos P, Joshi J, Oakley CM. Uses and limitations of high-dose dipyridamole stress echocardiography for evaluation of coronary artery disease. Br Heart J 1992;67: 144–9. Margonato A, Chierchia S, Cianflone D, et al. Limitations of dipyridamole-echocardiography in effort angina pectoris. Am J Cardiol 1987;59:225–31. Sawada SG, Segar DS, Ryan T, et al. Echocardiographic detection of coronary artery disease during dobutamine infusion. Circulation 1991;83:1601–14. Marcovitz PA, Armstrong WF. Accuracy of dobutamine stress echocardiography in detecting coronary artery disease. Am J Cardiol 1992;69:1269–73. Previtali M, Lanzarini L, Ferrario M, Tortorici M, Mussini A, Montemartini C. Dobutamine versus dipyridamole echocardiography in coronary artery disease. Circulation 1991;83(suppl III):27–31. Salustri A, Fioretti PM, McNeill AJ, Pozzoli MMA, Roelandt JRTC. Pharmacological stress echocardiography in the diagnosis of coronary artery disease and myocardial ischaemia: a comparison between dobutamine and dipyridamole. Eur Heart J 1992;13:1356–62. Martin TW, Seaworth JF, Johns JP, Pupa LE, Condos WR. Comparison of adenosine, dipyridamole and dobutamine in stress echocardiography. Ann Intern Med 1992;116:190–6. Beleslin BD, Ostojic M, Stepanovic J, et al. Stress echocardiography in the detection of myocardial ischemia. Head-to-head comparison of exercise, dobutamine and dipyridamole tests. Circulation 1994;90:1168–76. Dagianti A, Penco M, Agati L, et al. Stress echocardiography: comparison of exercise, dipyridamole and dobutamine in detecting and predicting the extent of coronary artery disease. J Am Coll Cardiol 1995;26:18–25. Leppo J, Boucher CA, Okada RD, Newell JB, Strauss HW, Pohost GM. Serial thallium-201 myocardial imaging after dipyridamole infusion: diagnostic utility in detecting coronary stenoses and relationship to regional wall motion. Circulation 1982;66:649–57. Ruddy TD, Dighero HR, Newell JB, et al. Quantitative analysis of dipyridamole-thallium images for the detection of coronary artery disease. J Am Coll Cardiol 1987;10:142–9. Kong BA, Shaw L, Miller DD, Chaitman BR. Comparison of accuracy for detecting coronary artery disease and side-effect profile of dipyridamole thallium-201 myocardial perfusion imaging in women versus men. Am J Cardiol 1992;70:168–73. Mason JR, Palac RT, Freeman ML, et al. Thallium scintigraphy during dobutamine infusion: nonexercise-dependent screening test for coronary disease. Am Heart J 1984;107:481–5. Pennell DJ, Underwood SR, Swanton RH, Walker JM, Ell PJ. Dobutamine thallium myocardial perfusion tomography. J Am Coll Cardiol 1991;18:1471–9. Hays JT, Mahmariam JJ, Cochran AJ, Verani MS. Dobutamine thallium-201 tomography for evaluating patients with suspected coronary artery disease unable to undergo exercise or vasodilator pharmacologic stress test. J Am Coll Cardiol 1993;21:1583–90. Kiat H, Maddahi J, Lynne TR, et al. Comparison of technetium 99 methoxyisobutylisonitrile and thallium 201 for evaluation of coronary artery disease by planar and tomographic methods. Am Heart J 1989;117:1–11. Iskandrian AS, Heo J, Hong B, Lyons E, Marsh S. Use of technetium 99m isonitrile (RP-30A) in assessing left ventricular perfusion and function at rest and during exercise in coronary artery disease, and comparison with coronary arteriography and exercise thallium-201 SPECT imaging. Am J Cardiol 1989;64: 270–5. Hoffmann R, Lethen H, Kleinhans E, et al. Comparative evaluation of bicycle and dobutamine stress echocardiography with perfusion scintigraphy and bicycle electrocardiogram for identification of coronary artery disease. Am J Cardiol 1993; 72:555–9. Marwick T, Willemart B, D'Hondt AM, et al. Selection of the optimal nonexercise stress for the evaluation of ischemic regional myocardial dysfunction and malperfusion. Comparsion of dobutamine and adenosine using echocardiography and 99m Tc-MIBI single photon emission computed tomography. Circulation 1993; 87:345–54. Marwick T, D'Hondt AM, Baudhuin T, et al. Optimal use of dobutamine stress for the detection and evaluation of coronary artery disease: combination with echocardiography or scintigraphy, or both? J Am Coll Cardiol 1993;22:159–67. Diamond GA, Forrester JS. Analysis of probability as an aid in the clinical diagnosis of coronary disease. N Engl J Med 1979;300: 1350–8. Bisi G, Sciagrà R, Santoro GM, Briganti V, Leoncini M, Fazzini PF. Evaluation of coronary artery disease extent using 99mTc-sestamibi: comparison of dipyridamole versus exercise and of planar versus tomographic imaging. Nucl Med Commun 1993;14: 946–54. Austen WG, Edwards JE, Frye RL, et al. A reporting system on patients evaluated for coronary artery disease: report of the Ad Hoc Committee for Grading of Coronary Artery Disease. Council on Cardiovascular Surgery, American Heart Association. Circulation 1975;51(suppl 51):5–40. Froelicher VF. Use of the exercise electrocardiogram to identify latent coronary atherosclerostic heart disease. In: Amsterdam EA, Wilmore JH, DeMaria AN, editors. Exercise in cardiovascular health and disease. New York: York Medical Books; 1977. p. 189–208. Verani MS. Myocardial perfusion imaging versus two-dimensional echocardiography: comparative value in the diagnosis of coronary artery disease. J Nucl Cardiol 1994;1:399–414. Fung AJ, Gallagher KP, Buda A. The physiologic basis of dobutamine as compared with dipyridamole stress interventions in the assessment of critical coronary stenosis. Circulation 1987;76: 943–51. Nguyen T, Heo J, Ogilby JD, et al. Single-photon emission computed tomography with thallium-201 during adenosine-induced coronary hyperemia: correlation with coronary arteriography, exercise thallium imaging and two-dimensional echocardiography. J Am Coll Cardiol 1990;16:1375–83. Amanullah AM, Bevegard S, Lindvall K, Aasa M. Assessment of left ventricular wall motion in angina pectoris by two-dimensional echocardiography and myocardial perfusion by technetium 99m sestamibi tomography during adenosine induced coronary vasodilation and comparison with coronary angiography. Am J Cardiol 1993;72:983–9. Geleijnse ML, Marwick TH, Boersma E, Deckers JW, Melin JA, Fioretti PM. Optimal pharmacological stress testing for the diagnosis of coronary artery disease: a probabilistic approach. Eur Heart J 1995;16(Suppl M):3–10. Gunalp B, Dokumaci B, Uyan C, et al. Value of dobutamine technetium 99m-sestamibi SPECT and echocardiography in the detection of coronary artery disease compared with coronary angiography. J Nucl Med 1993;34:889–94. Mairesse GH, Marwick TH, Vanoverschelde JJ, et al. How accurate is dobutamine stress electrocardiography for detection of coronary artery disease? Comparison with two-dimensional echocardiography and technetium 99m methoxy isobutyl isonitrile (Mibi) perfusion scintigraphy. J Am Coll Cardiol 1994;24:920–7. Kisacik HL, Ozdemir K, Altinyay, et al. Comparison of exercise stress testing with simultaneous dobutamine stress echocardiography and technetium 99m isonitrile single-photon emission computerized tomography for diagnosis of coronary artery disease. Eur Heart J 1996;17:113–9. Di Bello V, Bellina RC, Gori E, et al. Incremental diagnostic value of dobutamine stress echocardiography and dobutamine scintigraphy (technetium 99m-labeled sestamibi single-photon emission computed tomography) for assessment of presence and extent of coronary artery disease. J Nucl Cardiol 1996;3: 212–20. Elhendy A, Geleijnse ML, Roelandt JRTC, et al. Dobutamine-induced hypoperfusion without transient wall motion abnormalities: less severe ischemia or less severe stress? J Am Coll Cardiol 1996;27:323–9. Senior R, Sridara BS, Anagnostou E, Handler C, Raftery EB, Lahiri A. Synergistic value of simultaneous stress dobutamine sestamibi single-photon-emission computerized tomography and echocardiography in the detection of coronary artery disease. Am Heart J 1994;128:713–8. Armstrong WF, O'Donnel J, Ryan T, Feigenbaum H. Effect of prior myocardial infarction and extent and location of coronary disease on accuracy of exercise echocardiography. J Am Coll Cardiol 1987;10:531–8.