Polyethylene Liner Dissociation Is a Complication of the DePuy Pinnacle Cup: A Report of 23 Cases

Ovid Technologies (Wolters Kluwer Health) - Tập 474 - Trang 441-446 - 2015
Andrew Yun1, Emmanuel N. Koli2, John Moreland1, Richard Iorio3, John F. Tilzey4, J. Wesley Mesko5, Gwo-Chin Lee6, Mark Froimson7
1Providence Saint John’s Hospital, Santa Monica, USA
2Department of Orthopaedic Surgery and Rehabilitation, Howard University Hospital, Washington, USA
3Department of Orthopaedic Surgery, NYU Langone Medical Center, Hospital for Joint Diseases, New York, USA
4Lahey Clinic Foundation, Burlington, USA
5Michigan Orthopaedic Center, Lansing, USA
6Penn Presbyterian Medical Center, Philadelphia, USA
7Trinity Health, Livonia, USA

Tóm tắt

Polyethylene liner dissociation is a rare but catastrophic event in total hip arthroplasty (THA), and certain implant designs are known to be at greater risk. Although the DePuy Pinnacle (Warsaw, IN, USA) modular acetabular construct has an excellent record of fixation and wear, an unexpectedly high number of liner dissociations has been noted. The purposes of this study were (1) to characterize the clinical parameters observed in a large group of patients who have experienced liner dissociations with the DePuy Pinnacle acetabular component; (2) to describe the radiographic findings in this group of patients; and (3) to calculate a minimum frequency of this complication. Since 2001, 23 patients with previously well-functioning THAs presented with sudden atraumatic polyethylene liner dissociation at four separate institutions. These THAs were performed between 2001 and 2013. Eight different arthroplasty specialists had performed the index hip arthroplasties using the DePuy Pinnacle acetabular component with a polyethylene liner. Polyethylene failures were evaluated for liner type and radiographic cup position. For three of the surgeons who contributed cases, institutional registries allowed the calculation of the number of components of this type that they used during the period in question, which provided a conservative estimate of the frequency of this type of failure. All 23 liner failures occurred atraumatically in previously asymptomatic THAs at a mean of 48 months (range, 3–138 months). Patients characteristically reported a new and sudden onset of discomfort with audible, reproducible squeaking. Surgical inspection of dissociated liners demonstrated displacement of polyethylene with shearing of the peripheral locking tabs. Radiographic evaluation demonstrated that 14 cups were well positioned and nine cups were malpositioned outside the so-called safe zone. Conservative estimates of the frequency of this complication from the three surgeons’ practices whose institutional registries allowed calculation of the lowest possible frequency were 0.32% (six of 1888), 0.77% (three of 391), and 0.82% (three of 367). With this report of 23 additional liner dissociations, we suggest that surgeons should be aware of the problem and take extra precautions when using this implant to ensure locking mechanism integrity at the time of surgery. We caution that the frequency of liner dissociation may be higher than previously reported. Level IV, therapeutic study.

Tài liệu tham khảo

Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res. 1990;257:107–128. González della Valle A, Ruzo PS, Li S, Pellicci P, Sculco TP, Salvati EA. Dislodgment of polyethylene liners in first and second-generation Harris-Galante acetabular components. A report of eighteen cases. J Bone Joint Surg Am. 2001;83:553–559. Gray CF, Moore RE, Lee GC. Spontaneous dissociation of offset, face-changing polyethylene liners from the acetabular shell: a report of four cases. J Bone Joint Surg Am. 2012;94:841–845. Harris WH, Muratoglu OK. A review of current cross-linked polyethylenes used in total joint arthroplasty. Clin Orthop Relat Res. 2005;430:46–52. Jameson SS, Baker PN, Mason J, Rymaszewska M, Gregg PJ, Deehan DJ, Reed MR. Independent predictors of failure up to 7.5 years after 35,386 single-brand cementless total hip replacements: a retrospective cohort study using National Joint Registry data. Bone Joint J. 2013;95:747–757. Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220. Malik A, Dorr LD, Long WT. Impingement as a mechanism of dissociation of a Metasul metal-on-metal liner. J Arthroplasty. 2009;24:323.e13–16. MAUDE database. Available at: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfMAUDE/search.cfm. Accessed May 28, 2015. Mayer SW, Wellman SS, Bolognesi MP, Attarian DE. Late liner disassociation of a Pinnacle system acetabular component. Orthopedics. 2012;35:e561–565. Mesko JW. Acute liner disassociation of a Pinnacle acetabular component. J Arthroplasty. 2009;24:815–818. Postak PD, Ratzel AR, Greenwald AS. Highly crosslinked polyethylene modular acetabular designs: performance characteristics AAOS poster. Available at: http://orl-inc.com. Accessed March 26, 2011. Powers CC, Fricka KB, Austin MS, Engh CA Sr. Five Duraloc locking ring failures. J Arthroplasty. 2010;25:1170.e15–18. Powers CC, Ho H, Beykirch SE, Huynh C, Hopper RH Jr, Engh CA Jr, Engh CA. A comparison of a second- and a third-generation modular cup design: is new improved? J Arthroplasty. 2010;25:514–521. Retpen JB, Solgaard S. Late disassembly of modular acetabular components. A report of two cases. Acta Orthop Scand. 1993;64:193–195. Ries MD, Weaver K, Rose RM, Gunther J, Sauer W, Beals N. Fatigue strength of poly-ethylene after sterilization by gamma irradia-tion or ethylene oxide. Clin Orthop Relat Res. 1996;333:87–95. Saito S, Ryu J, Seki M, Ishii T, Saigo K, Mori S. Analysis and results of dissociation of the polyethylene liner in the Harris-Galante I ace-tabular component. J Arthroplasty. 2008;23:522-526. Tompkins GS, Jacobs JJ, Kull LR, Rosenberg AG, Galante JO. Primary total hip arthroplasty with a porous-coated acetabular component. Seven-to-ten year results. J Bone Joint Surg Am. 1997;79:169–176. Tradonsky S, Postak PD, Froimson AI, Greenwald AS. A comparison of the disassociation strength of modular acetabular components. Clin Orthop Relat Res. 1993;296:154–160. Werle J, Goodman S, Schurman D, Lannin J. Polyethylene liner dissociation in Harris-Galante acetabular components: a report of 7 cases. J Arthroplasty. 2002;17:78–81.