Intraosseous foreign body granuloma in rotator cuff repair with bioabsorbable suture anchor

Springer Science and Business Media LLC - Tập 130 - Trang 1037-1040 - 2010
T. Nusselt1, S. Freche1, H.-M. Klinger1, M. H. Baums1
1Department of Orthopaedic Surgery, University of Göttingen, Medical Center (UMG), Göttingen, Germany

Tóm tắt

Biodegradable implants lead to problems such as cyst formation, soft-tissue inflammation, loose implant fragments or local osteolysis. This report represents the first published case of an intraosseous foreign body granuloma in the humeral head after arthroscopic rotator cuff tear fixation with a poly-l-lactide (PLLA) suture anchor. A 48-year-old female patient presented with pain in her right shoulder. A refixation of her right supraspinatus tendon with a biodegradable suture anchor was performed 11 months ago at an external hospital. Laboratory tests showed normal values for C-reactive protein, leukocytes and the erythrocyte sedimentation rate. No signs of infection or instability were noted. The visual analogue scale (VAS) was 8, the simple shoulder test (SST) was 4 and the American shoulder and elbow surgeons score (ASES) was 44. Plain radiographs showed high lucency in the area of the tuberculum majus. MRI showed an intra- and extraosseous mass surrounded by fluid in this area. Surgical care involved arthroscopic debridement and removal of the suture anchor. Histological examination revealed a foreign body granuloma. At the 18-month follow-up the patient was nearly pain-free. The VAS was 2, SST was 10 and ASES was 88. Foreign body granulomas are a well known but rarely described complication that arises after the use of biodegradable suture anchors in shoulder surgery. Every patient presenting with shoulder pain after usage of a biodegradable fixation material should be evaluated closely. Orthopaedic surgeons should be aware of the possibility of delayed foreign body reactions, especially after using PLLA anchors.

Tài liệu tham khảo

Scheibel MT, Habermeyer P (2003) A modified Mason-Allen technique for rotator cuff repair using suture anchors. Arthroscopy 19:330–333 Spoliti M (2007) Glenoid osteolysis after arthroscopic labrum repair with a bioabsorbable suture anchor. Acta Orthop Belg 73:107–1010 Klinger HM, Buchhorn GH, Heidrich G, Kahl E, Baums MH (2008) Biomechanical evaluation of rotator cuff repairs in a sheep model: suture anchors using arthroscopic Mason-Allen stitches compared with transosseous sutures using traditional modified Mason-Allen stitches. Clin Biomech 23:291–298 McFarland EG, Park HB, Keyurapan E, Gill HS, Selhi S (2005) Suture anchors and tacks for shoulder surgery, part 1. Am J Sports Med 33:1918–1923 Goradia VK, Mullen DJ, Boucher HR, Parks BG, O’Donnell JB (2001) Cyclic loading of rotator cuff repairs: a comparison of bioabsorbable tacks with metal suture anchors and transosseous sutures. Arthroscopy 17:360–364 Burkhart SS (2005) Letter to the editor. Am J Sports Med 33:11 McGuire DA, Barber FA, Elrod BF, Paulos LE (1999) Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction. Arthroscopy 15:463–473 Weiler A, Windhagen HJ, Raschke MJ, Laumeyer A, Hoffmann RF (1998) Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws. Am J Sports Med 26:119–127 Böstman OM (1991) Current concepts review: absorbable implants for the fixation of fractures. J Bone Joint Surg 73-A:148–153 Böstman O, Päivärinta U, Partio E, Vasenius J, Manninen M, Rokkanen P (1992) Degradation and tissue replacement of an absorbable polyglycolide screw in the fixation of rabbit femoral osteotomies. J Bone Joint Surg 74-A:1021–1031 Bergsma EJ, de Bruijn WC, Rozema FR, Bos RRM, Boering G (1995) Late degradation tissue response to poly(l-lactide) bone plates and screws. Biomaterials 16:25–31 Suuronen R, Pohjonen T, Hietanen J, Lindqvist C (1998) A 5-year in vitro and in vivo study of the biodegradation of polylactide plates. J Oral Maxillofac Surg 56:604–614 Böstman OM, Pihlajamaki HK (2000) Adverse tissue reactions to bioabsorbable fixation devices. Clin Orthop Rel Res 371:216–227 Freehill MQ, Harms DJ, Huber SM, Atlihan D, Buss DD (2003) Poly-l-lactic acid tack synovitis after arthroscopic stabilization of the shoulder. Am J Sports Med 31:643–647 Peltoniemi H, Ashammakhi N, Kontio R, Waris T, Salo A, Lindqvist C, Grätz K, Suuronen R (2002) The use of bioabsorbable osteofixation devices in craniomaxillofacial surgery. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 94:5–14 Glueck D, Wilson TC, Johnson DL (2005) Extensive osteolysis after rotator cuff repair with a bioabsorbable suture anchor. Am J Sports Med 33:742–744 Müller M, Kääb MJ, Villiger C, Holzach P (2002) Osteolysis after open shoulder stabilization using a new bio-resorbable bone anchor: a prospective, non-randomized clinical trial. Injury 33:30–36 Athwal GS, Shridharani SM, O’Driscoll SW (2006) Osteolysis and arthropathy of the shoulder after use of bioabsorbable knotless suture anchors. J Bone Joint Surg Am 88:1840–1845 Benedetto KP, Fellinger M, Lim TE, Passler JM, Schoen JL, Willems WJ (2000) A new bioabsorbable interference screw: preliminary results of a prospective, multicenter, randomized clinical trial. Arthroscopy 16:41–48 Barber FA, Snyder SJ, Abrams JS, Fanelli GC, Savoie FH 3rd (2003) Arthroscopic Bankart reconstruction with a bioabsorbable anchor. J Shoulder Elbow Surg 12:535–538 Warme WJ, Arciero RA, Savoie FH 3rd, Uhorchak JM, Walton M (1999) Nonabsorbable versus absorbable suture anchors for open Bankart repair. A prospective, randomized comparison. Am J Sports Med 27:742–746 Böstman OM, Pihlajamäki HK (1998) Late foreign-body reaction to an intraosseous bioabsorbable polylactic acid screw. A case report. J Bone Joint Surg 80:1791–1794 Meyer DC, Gerber C (2004) Failure of anterior shoulder instability repair caused by eyelet cutout of absorbable suture anchors. Arthroscopy 20:521–523 Pihlajamäki H, Böstman O, Hirvensalo E, Tömälä P, Rokkanen P (1992) Absorbable pins of self-reinforced poly-l-lactic acid for fixation of fractures and osteotomies. J Bone Joint Surg 74:853–857 Matsusue Y, Hanafusa S, Yamamuro T, Shikinami Y, Ikada Y (1995) Tissue reaction of bioabsorbable ultra high strength poly (l-lactide) rod. A long-term study in rabbits. Clin Orthop 317:246–253 Rokkanen PU, Böstman O, Hirvensalo E, Mäkelä EA, Partio EK, Pätiälä H, Vainionpää SI, Vihtonen K, Törmälä P (2000) Bioabsorbable fixation in orthopaedic surgery and traumatology. Biomaterials 21:2607–2613 Kääb MJ, Rahn BA, Weiler A, Curtis R, Perren SM, Schneider E (2002) Osseous integration of poly-(l-co-d/l-lactide) 70/30 and titanium suture anchors: an experimental study in sheep cancellous bone. Injury 33:B37–B42 Lohrbach O, Wilmes P, Brogard P, Seil R (2008) Complications related to implants in arthroscopic shoulder surgery [German]. Orthopäde 37:1073–1079