Electrochemically reduced graphene oxide modified with electrodeposited thionine and horseradish peroxidase for hydrogen peroxide sensing and inhibitive measurement of chromium

Materials Science for Energy Technologies - Tập 2 - Trang 676-686 - 2019
Shailendra Kumar Pandey1, Sadhana Sachan2, Sunil Kumar Singh3
1Department of Chemical Engineering, Harcourt Butler Technical University, Kanpur, India
2Department of Chemical Engineering, Motilal Nehru National Institute of Technology, Allahabad, India
3Department of Animal Sciences, School of Basic and Applied Sciences, Central University of Punjab, Bathinda 151001 Punjab, India

Tài liệu tham khảo

Järup, 2003, Hazards of heavy metal contamination, Br. Med. Bull., 68, 167, 10.1093/bmb/ldg032 Olafisoye, 2013, Heavy metals contamination of water, soil, and plants around an electronic waste dumpsite, Pol. J. Environ. Stud., 22, 1431 Davis, 1999, Evaluation of lead concentration in runoff from painted structures, Water Res., 33, 2949, 10.1016/S0043-1354(98)00509-0 Long, 2002, Current status and perspective on phytoremediation of heavy metal polluted soils, J. Appl. Ecol., 13, 757 Ghica, 2013, Glucose oxidase enzyme inhibition sensors for heavy metals at carbon film electrodes modified with cobalt or copper hexacyanoferrate, Sens. Actuators, B, 178, 270, 10.1016/j.snb.2012.12.113 Michel, 2003, Amperometric cytochrome c3-based biosensor for chromate determination, Biosens. Bioelectron., 19, 345, 10.1016/S0956-5663(03)00191-X Costa, 2003, Potential hazards of hexavalent chromate in our drinking water, Toxicol. Appl. Pharmacol., 188, 1, 10.1016/S0041-008X(03)00011-5 Ouyang, 2012, Flower-like self-assembly of gold nanoparticles for highly sensitive electrochemical detection of chromium (VI), Anal. Chim. Acta, 722, 1, 10.1016/j.aca.2012.01.032 Xi, 2008, One-step construction of biosensor based on chitosan–ionic liquid–horseradish peroxidase biocomposite formed by electrodeposition, Biosens. Bioelectron., 24, 29, 10.1016/j.bios.2008.03.023 Noh, 2012, Application of a Cu–Co alloy dendrite on glucose and hydrogen peroxide sensors, Electrochim. Acta, 61, 36, 10.1016/j.electacta.2011.11.066 Yao, 2006, A highly sensitive hydrogen peroxide amperometric sensor based on MnO2 nanoparticles and dihexadecyl hydrogen phosphate composite film, Anal. Chim. Acta, 557, 78, 10.1016/j.aca.2005.10.052 Ujjain, 2014, Nanoceria based electrochemical sensor for hydrogen peroxide detection, Biointerphases, 9, 10.1116/1.4890473 Malassa, 2013, Determination of different trace heavy metals in ground water of South West Bank/Palestine by ICP/MS, J. Environ. Prot., 4, 818, 10.4236/jep.2013.48096 Shaw, 2004, The determination of trace metal pollutants in environmental matrices using ion chromatography, Environ. Int., 30, 403, 10.1016/j.envint.2003.09.009 Hurdis, 1954, Accuracy of determination of hydrogen peroxide by cerate oxidimetry, Anal. Chem., 26, 320, 10.1021/ac60086a016 Zhang, 1999, Optimal conditions and sample storage for the determination of H2O2 in marine waters by the scopoletin–horseradish peroxidase fluorometric method, Talanta, 48, 1031, 10.1016/S0039-9140(98)00312-9 Hanaoka, 2001, Chemiluminescent flow sensor for H2O2 based on the decomposition of H2O2 catalyzed by cobalt (II)-ethanolamine complex immobilized on resin, Anal. Chim. Acta, 426, 57, 10.1016/S0003-2670(00)01181-8 Matsubara, 1992, Oxo [5,10,15,20-tetra (4-pyridyl) porphyrinato] titanium (IV): an ultra-high sensitivity spectrophotometric reagent for hydrogen peroxide, Analyst, 117, 1781, 10.1039/an9921701781 Evtugyn, 1998, Sensitivity and selectivity of electrochemical enzyme sensors for inhibitor determination, Talanta, 46, 465, 10.1016/S0039-9140(97)00313-5 Wang, 2008, Electrochemical sensors for clinic analysis, Sensors, 8, 2043, 10.3390/s8042043 Pedrero, 2014, Electrochemical biosensors for the determination of cardiovascular markers: a review, Electroanalysis, 26, 1132, 10.1002/elan.201300597 Mandal, 2018, Evolving trends in bio/chemical sensor fabrication incorporating bimetallic nanoparticles, Biosens. Bioelectron., 117, 546, 10.1016/j.bios.2018.06.039 Kuldeep, 2019, Gold nanoparticle surface engineering strategies and their applications in biomedicine and diagnostics, 3 Biotech, 9, 57 Chandra, 2016, Nanobiosensors for personalized and onsite biomedical diagnosis, Inst. Eng. Technol. Srivastava, 2015, Marine biomaterials in therapeutics and diagnostic, 1247 Baranwal, 2018, Design of commercially comparable nanotherapeutic agent against human disease-causing parasite, Leishmania, Sci. Rep., 8, 8814, 10.1038/s41598-018-27170-1 Mahato, 2018, Fundamentals and commercial aspects of nanobiosensors in point-of-care clinical diagnostics, 3 Biotech, 8, 149, 10.1007/s13205-018-1148-8 Chandra, 2017 Bertocchi, 1999, Flow injection analysis of mercury (II) in pharmaceuticals based on enzyme inhibition and biosensor detection, J. Pharm. Biomed. Anal., 20, 263, 10.1016/S0731-7085(99)00032-1 vel Krawczyk, 2000, Inhibitive determination of mercury and other metal ions by potentiometric urea biosensor, Biosens. Bioelectron., 15, 681, 10.1016/S0956-5663(00)00085-3 Renedo, 2004, Optimisation procedure for the inhibitive determination of chromium (III) using an amperometric tyrosinase biosensor, Anal. Chim. Acta, 521, 215, 10.1016/j.aca.2004.06.026 Stoytcheva, 1998, Electrochemical approach in studying the inhibition of acetylcholinesterase by arsenate (III): analytical characterisation and application for arsenic determination, Anal. Chim. Acta, 364, 195, 10.1016/S0003-2670(98)00134-2 Nomngongo, 2011, Determination of selected heavy metals using amperometric horseradish peroxidase (HRP) inhibition biosensor, Anal. Lett., 44, 2031, 10.1080/00032719.2010.539738 Han, 2001, A methylene blue-mediated enzyme electrode for the determination of trace mercury (II), mercury (I), methylmercury, and mercury–glutathione complex, Biosens. Bioelectron., 16, 9, 10.1016/S0956-5663(00)00114-7 Qian, 2006, Composite film of carbon nanotubes and chitosan for preparation of amperometric hydrogen peroxide biosensor, Talanta, 68, 721, 10.1016/j.talanta.2005.05.030 Yi, 2000, Direct electrochemistry of horseradish peroxidase immobilized on a colloid/cysteamine-modified gold electrode, Anal. Biochem., 278, 22, 10.1006/abio.1999.4360 He, 2004, Electrocatalytic properties of heme proteins in layer-by-layer films assembled with SiO2 nanoparticles, Electroanalysis, 16, 1122, 10.1002/elan.200403000 Mahiuddin, 2005, Horseradish peroxidase activity in a reverse catanionic microemulsion, Langmuir, 21, 5259, 10.1021/la047161r Novoselov, 2004, Electric field effect in atomically thin carbon films, Science, 306, 666, 10.1126/science.1102896 Pumera, 2010, Graphene-based nanomaterials and their electrochemistry, Chem. Soc. Rev., 39, 4146, 10.1039/c002690p Shao, 2010, Graphene based electrochemical sensors and biosensors: a review, Electroanalysis, 22, 1027, 10.1002/elan.200900571 Zhou, 2009, Controlled synthesis of large-area and patterned electrochemically reduced graphene oxide films, Chem. Eur. J., 15, 6116, 10.1002/chem.200900596 Wang, 2009, Inhibitive determination of heavy metal ions by conductometric nitrate reductase biosensor, Chem. Res. Chin. Univ., 25, 443 Arvand, 2003, Electrochemical study of methylene blue incorporated into mordenite type zeolite and its application for amperometric determination of ascorbic acid in real samples, Anal. Chim. Acta, 491, 193, 10.1016/S0003-2670(03)00790-6 Karyakin, 2004, Prussian blue based nanoelectrode arrays for H2O2 detection, Anal. Chem., 76, 474, 10.1021/ac034859l John, 2004, Microenvironment effects on the electrochemical and photoelectrochemical properties of thionine loaded Nafion® films, J. Electroanal. Chem., 561, 119, 10.1016/j.jelechem.2003.07.025 Chen, 2011, A facile method to prepare stable noncovalent functionalized graphene solution by using thionine, Mater. Res. Bull., 46, 583, 10.1016/j.materresbull.2010.12.024 Wei, 2010, A novel label-free electrochemical immunosensor based on graphene and thionine nanocomposite, Sens. Actuator, B, 149, 314, 10.1016/j.snb.2010.06.008 Kong, 2012, Graphene oxide–thionine–Au nanostructure composites: preparation and applications in non-enzymatic glucose sensing, Electrochem. Commun., 14, 59, 10.1016/j.elecom.2011.11.004 Li, 2014, Square wave anodic stripping voltammetric determination of Cd2+ and Pb2+ at bismuth–film electrode modified with electroreduced graphene oxide–supported thiolated thionine, Talanta, 122, 285, 10.1016/j.talanta.2014.01.062 Guo, 2009, A green approach to the synthesis of graphene nanosheets, ACS Nano, 3, 2653, 10.1021/nn900227d Wang, 2009, Direct electrochemical reduction of single-layer graphene oxide and subsequent functionalization with glucose oxidase, J. Phys. Chem. C, 113, 14071, 10.1021/jp906348x Ping, 2011, Direct electrochemical reduction of graphene oxide on ionic liquid doped screen-printed electrode and its electrochemical biosensing application, Biosens. Bioelectron., 28, 204, 10.1016/j.bios.2011.07.018 Chen, 2011, Direct electrodeposition of reduced graphene oxide on glassy carbon electrode and its electrochemical application, Electrochem. Commun., 13, 133, 10.1016/j.elecom.2010.11.033 Crespilho, 2006, A strategy for enzyme immobilization on layer-by-layer dendrimer–gold nanoparticle electrocatalytic membrane incorporating redox mediator, Electrochem. Commun., 8, 1665, 10.1016/j.elecom.2006.07.032 Hildebrandt, 2008, Development of a portable biosensor for screening neurotoxic agents in water samples, Talanta, 75, 1208, 10.1016/j.talanta.2008.01.033 Raghu, 2012, Development of AChE biosensor for the determination of methyl parathion and monocrotophos in water and fruit samples: a cyclic voltammetric study, J. Electroanal. Chem., 665, 76, 10.1016/j.jelechem.2011.11.020 Ban, 2012, Graphene oxide and its electrochemical performance, Int. J. Electrochem. Sci., 7, 4345, 10.1016/S1452-3981(23)19543-5 Zaid, 2015, Reduction of graphene oxide nanosheets by natural beta carotene and its potential use as supercapacitor electrode, Arabian J. Chem., 8, 560, 10.1016/j.arabjc.2014.11.036 Deng, 2008, A sensitive NADH and glucose biosensor tuned by visible light based on thionine bridged carbon nanotubes and gold nanoparticles multilayer, Biosens. Bioelectron., 24, 951, 10.1016/j.bios.2008.07.066 Kang, 2012, Study on a hydrogen peroxide biosensor based on horseradish peroxidase/GNPs-thionine/chitosan, Electrochim. Acta, 62, 327, 10.1016/j.electacta.2011.12.034 Gu, 2014, Direct electrochemistry and electrocatalysis of horseradish peroxidase immobilized in a DNA/chitosan-Fe3O4 magnetic nanoparticle bio-complex film, Materials, 7, 1069, 10.3390/ma7021069 Zhao, 2012, Direct electrochemistry and electrocatalysis of horseradish peroxidase on a gold electrode modified with a polystyrene and multiwalled carbon nanotube composite film, Microchim. Acta, 176, 177, 10.1007/s00604-011-0699-8 Laviron, 1979, General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems, J. Electroanal. Chem., 101, 19, 10.1016/S0022-0728(79)80075-3 Manea, 2008, Voltammetric detection of urea on an Ag-modified zeolite-expanded graphite-epoxy composite electrode, Sensors, 8, 5806, 10.3390/s8095806 Brown, 1977, Cyclic and differential pulse voltammetric behavior of reactants confined to the electrode surface, Anal. Chem., 49, 1589, 10.1021/ac50019a033 Yang, 2004, Bienzymatic amperometric biosensor for choline based on mediator thionine in situ electropolymerized within a carbon paste electrode, Anal. Biochem., 334, 127, 10.1016/j.ab.2004.07.009 Shi, 2008, Amperometric H2O2 biosensor based on poly-thionine nanowire/HRP/nano-Au-modified glassy carbon electrode, Sens. Actuators, B, 129, 779, 10.1016/j.snb.2007.09.062 Amine, 2006, Enzyme inhibition-based biosensors for food safety and environmental monitoring, Biosens. Bioelectron., 21, 1405, 10.1016/j.bios.2005.07.012 Xiang, 2009, Direct electrochemistry and enhanced electrocatalysis of horseradish peroxidase based on flowerlike ZnO–gold nanoparticle–Nafion nanocomposite, Sens. Actuators, B, 136, 158, 10.1016/j.snb.2008.10.058 Zhao, 2008, Direct electrochemistry and electrocatalysis of horseradish peroxidase based on clay–chitosan-gold nanoparticle nanocomposite, Biosens. Bioelectron., 23, 1032, 10.1016/j.bios.2007.10.012 Tan, 2009, Amperometric hydrogen peroxide biosensor based on horseradish peroxidase immobilized on Fe3O4/chitosan modified glassy carbon electrode, Electroanalysis, 21, 1514, 10.1002/elan.200804572 Lei, 2003, Immobilization of horseradish peroxidase to a nano-Au monolayer modified chitosan-entrapped carbon paste electrode for the detection of hydrogen peroxide, Talanta, 59, 981, 10.1016/S0039-9140(02)00641-0 You, 2013, Novel determination of hydrogen peroxide by electrochemically reduced graphene oxide grafted with aminothiophenol–Pd nanoparticles, Sens. Actuators, B, 178, 450, 10.1016/j.snb.2013.01.006 Bui, 2010, Electrocatalytic reduction of hydrogen peroxide by silver particles patterned on single-walled carbon nanotubes, Sens. Actuators, B, 150, 436, 10.1016/j.snb.2010.06.019 Han, 2013, One-step synthesis of poly (thionine)-Au nano-network and nanowires and its application for non-enzyme biosensing of hydrogen peroxide, Electrochem. Commun., 33, 47, 10.1016/j.elecom.2013.04.027 Gao, 2007, Amperometric hydrogen peroxide biosensor based on the immobilization of HRP on nano-Au/Thi/poly (p-aminobenzene sulfonic acid)-modified glassy carbon electrode, J. Biochem. Biophys. Methods, 70, 407, 10.1016/j.jbbm.2006.09.007