Experimental investigation of filled bed effect on the thermal performance of a wet cooling tower by using ZnO/water nanofluid

Energy Conversion and Management - Tập 127 - Trang 199-207 - 2016
Peyman Imani-Mofrad1, Zeinali Heris Saeed1,2, Mehdi Shanbedi1
1Department of Chemical Engineering, Faculty of Engineering, Ferdowsi University of Mashhad, Mashhad, Iran
2Faculty of Chemical and Petroleum Engineering, University of Tabriz, Tabriz, Iran

Tài liệu tham khảo

Cheremisinoff NP, Cheremisinoff PN. Cooling towers selection, design and practice; 1981. Qi, 2007, Performance characteristics of a shower cooling tower, Energy Convers Manage, 48, 193, 10.1016/j.enconman.2006.04.021 Hensley, 2006 Milosavljevic, 2001, A comprehensive approach to cooling tower design, Appl Therm Eng, 21, 899, 10.1016/S1359-4311(00)00078-8 Goshayshi, 2000, The investigation of cooling tower packing in various arrangements, Appl Therm Eng, 20, 69, 10.1016/S1359-4311(99)00011-3 Singh, 2016, An experimental and multi-objective optimization study of a forced draft cooling tower with different fills, Energy Convers Manage, 111, 417, 10.1016/j.enconman.2015.12.080 Lucas, 2013, Experimental study on the performance of a mechanical cooling tower fitted with different types of water distribution systems and drift eliminators, Appl Therm Eng, 50, 282, 10.1016/j.applthermaleng.2012.06.030 Hajidavalloo, 2010, Thermal performance of cross flow cooling towers in variable wet bulb temperature, Energy Convers Manage, 51, 1298, 10.1016/j.enconman.2010.01.005 Gu, 2016, A numerical study on the mechanism and optimization of wind-break structures for indirect air-cooling towers, Energy Convers Manage, 108, 43, 10.1016/j.enconman.2015.11.006 Naphon, 2005, Study on the heat transfer characteristics of an evaporative cooling tower, Int Commun Heat Mass Transfer, 32, 1066, 10.1016/j.icheatmasstransfer.2005.05.016 Mondal, 2015, Investigation of the crosswind-influenced thermal performance of a natural draft counterflow cooling tower, Int J Heat Mass Transf, 85, 1049, 10.1016/j.ijheatmasstransfer.2015.02.048 Smrekar, 2006, Improving the efficiency of natural draft cooling towers, Energy Convers Manage, 47, 1086, 10.1016/j.enconman.2005.07.012 Ma, 2015, Effects of ambient temperature and crosswind on thermo-flow performance of the tower under energy balance of the indirect dry cooling system, Appl Therm Eng, 78, 90, 10.1016/j.applthermaleng.2014.12.048 Muangnoi, 2008, Effects of inlet relative humidity and inlet temperature on the performance of counterflow wet cooling tower based on exergy analysis, Energy Convers Manage, 49, 2795, 10.1016/j.enconman.2008.03.019 Lu, 2015, Experimental study of crosswind effects on the performance of small cylindrical natural draft dry cooling towers, Energy Convers Manage, 91, 238, 10.1016/j.enconman.2014.12.018 Askari, 2016, A novel approach for energy and water conservation in wet cooling towers by using MWNTs and nanoporous graphene nanofluids, Energy Convers Manage, 109, 10, 10.1016/j.enconman.2015.11.053 Chol, 1995, Enhancing thermal conductivity of fluids with nanoparticles, ASME-Publications-Fed, 231, 99 Amiri, 2015, Performance dependence of thermosyphon on the functionalization approaches: an experimental study on thermo-physical properties of graphene nanoplatelet-based water nanofluids, Energy Convers Manage, 92, 322, 10.1016/j.enconman.2014.12.051 Amiri, 2015, Synthesis of ethylene glycol-treated graphene nanoplatelets with one-pot, microwave-assisted functionalization for use as a high performance engine coolant, Energy Convers Manage, 101, 767, 10.1016/j.enconman.2015.06.019 Shanbedi, 2015, Synthesis of aspartic acid-treated multi-walled carbon nanotubes based water coolant and experimental investigation of thermal and hydrodynamic properties in circular tube, Energy Convers Manage, 105, 1366, 10.1016/j.enconman.2015.09.002 Amiri, 2015, Laminar convective heat transfer of hexylamine-treated MWCNTs-based turbine oil nanofluid, Energy Convers Manage, 105, 355, 10.1016/j.enconman.2015.07.066 Ponmani, 2014, Formation and characterization of thermal and electrical properties of CuO and ZnO nanofluids in xanthan gum, Colloids Surf A: Physicochem Eng Aspects, 443, 37, 10.1016/j.colsurfa.2013.10.048 Rao, 2011, Optimization of mechanical draft counter flow wet-cooling tower using artificial bee colony algorithm, Energy Convers Manage, 52, 2611, 10.1016/j.enconman.2011.02.010 Lucas, 2009, Experimental study on the thermal performance of a mechanical cooling tower with different drift eliminators, Energy Convers Manage, 50, 490, 10.1016/j.enconman.2008.11.008 Lemouari, 2009, Experimental analysis of heat and mass transfer phenomena in a direct contact evaporative cooling tower, Energy Convers Manage, 50, 1610, 10.1016/j.enconman.2009.02.002 Treybal, 1980 Alavi, 2016, Experimental investigation on thermal performance of natural draft wet cooling towers employing an innovative wind-creator setup, Energy Convers Manage, 122, 504, 10.1016/j.enconman.2016.06.016 Pak, 1998, Hydrodynamic and heat transfer study of dispersed fluids with submicron metallic oxide particles, Exp Heat Transf Int J, 11, 151, 10.1080/08916159808946559 Holman, 1994