Pitfalls in automatic limb lengthening – First results with an intramedullary lengthening device

Orthopaedics & Traumatology: Surgery & Research - Tập 102 - Trang 851-855 - 2016
T.M. Tiefenboeck1, L. Zak1, A. Bukaty2, G.E. Wozasek1
1Medical University of Vienna, Department of Trauma Surgery, Medical University of Vienna, Waehringerguertel 18–20, 1090 Vienna, Austria
2Devision of General Anaesthesia and Intensive Care Medicine, Medical University of Vienna, Waehringerguertel 18–20, 1090 Vienna, Austria

Tài liệu tham khảo

Ilizarov, 1990, Clinical application of the tension-stress effect for limb lengthening, Clin Orthop Relat Res, 250, 8, 10.1097/00003086-199001000-00003 Manner, 2007, Accuracy of complex lower limb deformity correction with external fixation: a comparison of the Taylor Spatial Frame with the Ilizarov ring fixator, J Child Orthop, 1, 55, 10.1007/s11832-006-0005-1 Dammerer, 2011, Clinical value of the Taylor Spatial Frame: a comparison with the Ilizarov and Orthofix fixators, J Child Orthop, 5, 343, 10.1007/s11832-011-0361-3 Kenawey, 2011, Insufficient bone regenerate after intramedullary femoral lengthening: risk factors and classification system, Clin Orthop Relat Res, 469, 264, 10.1007/s11999-010-1332-6 Burghardt, 2011, Mechanical failure of the intramedullary skeletal kinetic distractor in limb lengthening, J Bone Joint Surg Br, 93, 639, 10.1302/0301-620X.93B5.25986 Simpson, 2009, Femoral lengthening with the intramedullary skeletal kinetic distractor, J Bone Joint Surg Br, 91, 955, 10.1302/0301-620X.91B7.21466 Kucukkaya, 2009, The new intramedullary cable bone transport technique, J Orthop Trauma, 23, 531, 10.1097/BOT.0b013e3181a2a8e7 Baumgart, 2005, The management of leg length discrepancy in Ollier's disease with a fully implantable lengthening nail, J Bone Joint Surg Br, 87, 1000, 10.1302/0301-620X.87B7.16365 Hankemeier, 2004, Improved comfort in lower limb lengthening with the intramedullary skeletal kinetic distractor. Principles and preliminary clinical experiences, Arch Orthop Trauma Surg, 124, 129, 10.1007/s00402-003-0625-6 Guichet, 2003, Gradual femoral lengthening with the Albizzia intramedullary nail, J Bone Joint Surg Am, 85-A, 838, 10.2106/00004623-200305000-00011 Cole, 2001, The intramedullary skeletal kinetic distractor (ISKD): first clinical results of a new intramedullary nail for lengthening of the femur and tibia, Injury, 32, Sd129, 10.1016/S0020-1383(01)00116-4 Betz, 1990, [First fully implantable intramedullary system for callus distraction – intramedullary nail with programmable drive for leg lengthening and segment displacement. Principles and initial clinical results], Chirurg, 61, 605 Kenawey, 2011, Leg lengthening using intramedullay skeletal kinetic distractor: results of 57 consecutive applications, Injury, 42, 150, 10.1016/j.injury.2010.06.016 Hankemeier, 2005, Limb lengthening with the intramedullary skeletal kinetic distractor (ISKD), Oper Orthop Traumatol, 17, 79, 10.1007/s00064-005-1123-5 Thaller, 2013, Limb lengthening with fully implantable magnetically actuated mechanical nails (PHENIX) – preliminary results, Injury, 1, 60 Krieg, 2008, Leg lengthening with a motorized nail in adolescents: an alternative to external fixators?, Clin Orthop Relat Res, 466, 189, 10.1007/s11999-007-0040-3 Dincyurek, 2012, Functional results of lower extremity lengthening by motorized intramedullary nails, Acta Orthop Traumatol Turc, 46, 42, 10.3944/AOTT.2012.2671 Garcia-Cimbrelo, 2002, The intramedullary elongation nail for femoral lengthening, J Bone Joint Surg Br, 84, 971, 10.1302/0301-620X.84B7.12984 Konofaos, 2012, A novel device for long bone osteodistraction: description of device and case series, Plast Reconstr Surg, 130, 418e, 10.1097/PRS.0b013e31825dc069 Baumann, 1977, [The extension nail. A new method for lengthening of the femur and tibia (author's transl)], Arch Orthop Unfallchir, 90, 139, 10.1007/BF00414987 Bliskunov, 1984, [Implantable devices for lengthening the femur without external drive mechanisms], Med Tekh, 2, 44 Mahboubian, 2012, Femoral lengthening with lengthening over a nail has fewer complications than intramedullary skeletal kinetic distraction, Clin Orthop Relat Res, 470, 1221, 10.1007/s11999-011-2204-4 Papanna, 2011, Promises and difficulties with the use of femoral intramedullary lengthening nails to treat limb length discrepancies, Acta Orthop Belg, 77, 788 Schiedel, 2011, Intramedullary limb lengthening with the intramedullary skeletal kinetic distractor in the lower limb, J Bone Joint Surg Br, 93, 788, 10.1302/0301-620X.93B6.25581 Simpson, 2000, Fracture after distraction osteogenesis, J Bone Joint Surg Br, 82, 659, 10.1302/0301-620X.82B5.9945 Wang, 2012, Intramedullary skeletal kinetic distractor in the treatment of leg length discrepancy – a review of 16 cases and analysis of complications, J Orthop Trauma, 26, e138, 10.1097/BOT.0b013e318238b5b1 Ware, 1992, The MOS 36-item short-form health survey (SF-36). I. Conceptual framework and item selection, Med Care, 30, 473, 10.1097/00005650-199206000-00002 Paley, 1990, Problems, obstacles, and complications of limb lengthening by the Ilizarov technique, Clin Orthop Relat Res, 250, 81, 10.1097/00003086-199001000-00011 Kirane, 2014, Precision of the PRECICE® internal bone lengthening nail, Clin Orthop Relat Res, 472, 3869, 10.1007/s11999-014-3575-0 Paley, 2015, PRECICE® intramedullary limb lengthening system, Expert Rev Med Devices, 12, 231, 10.1586/17434440.2015.1005604 Schiedel, 2014, How precise is the PRECICE® compared to the ISKD in intramedullary limb lengthening? Reliability and safety in 26 procedures, Acta Orthop, 85, 293, 10.3109/17453674.2014.913955 Tiefenbock, 2015, Unusual complication with an intramedullary lengthening device 15 months after implantation, Injury, 46, 2069, 10.1016/j.injury.2015.07.033 Accadbled, 2016, Bone lengthening using the Fitbone® motorized intramedullary nail: the first experience in France, Orthop Trauma Surg Res, 102, 217, 10.1016/j.otsr.2015.10.011