Development of a new control method for the dynamic liquid desiccant dehumidification process

Energy and Buildings - Tập 269 - Trang 112239 - 2022
Xiaobo Zhang1, Xiangguo Xu1,2, Xinyue Ma1
1Institute of Refrigeration and Cryogenics, Key Laboratory of Refrigeration and Cryogenic Technology of Zhejiang Province, Zhejiang University, No.38 Zheda Road, Hangzhou, 310027, China
2Center for Balance Architecture, Zhejiang University, No. 148 Tianmushan Road, Hangzhou 310027, China

Tài liệu tham khảo

Gandhidasan, 2011, Artificial neural network analysis of liquid desiccant dehumidification system, Energy, 36, 1180, 10.1016/j.energy.2010.11.030 Qu, 2014, New configurations of a heat recovery absorption heat pump integrated with a natural gas boiler for boiler efficiency improvement, Energy Convers. Manage., 87, 175, 10.1016/j.enconman.2014.06.083 Fu, 2017, Review of the impact of liquid desiccant dehumidification on indoor air quality, Build. Environ., 116, 158, 10.1016/j.buildenv.2017.02.014 Peng, 2017, Mathematical model and performance analysis of a novel outside evaporative cooling liquid desiccant dehumidifier, Int. J. Refrig, 82, 212, 10.1016/j.ijrefrig.2017.06.028 Ertas, 1997, Experimental investigations on the performance of a packed bed dehumidifier for various climatic conditions, Drying Technol., 15, 1061, 10.1080/07373939708917277 Fekadu, 2018, Renewable energy for liquid desiccants air conditioning system: A review, Renew. Sustain. Energy Rev., 93, 364, 10.1016/j.rser.2018.05.016 Gurubalan, 2019, A comprehensive review of liquid desiccant air conditioning system, Appl. Energy, 254, 10.1016/j.apenergy.2019.113673 Öberg, 1998, Experimental study of the heat and mass transfer in a packed bed liquid desiccant air dehumidifier, J. Sol. Energy Eng., 120, 289, 10.1115/1.2888133 Zhang, 2010, Experimental analysis of mass transfer in adiabatic structured packing dehumidifier/regenerator with liquid desiccant, Int. J. Heat Mass Transf., 53, 2856, 10.1016/j.ijheatmasstransfer.2010.02.012 Liu, 2008, Coupled heat and mass transfer characteristic in packed bed dehumidifier/regenerator using liquid desiccant, Energy Convers. Manage., 49, 1357, 10.1016/j.enconman.2008.01.009 Rahimi, 2013, Mathematical modeling of a packed-bed air dehumidifier: The impact of empirical correlations, J. Petrol. Sci. Eng., 108, 222, 10.1016/j.petrol.2013.03.031 Wen, 2019, A review of correlations and enhancement approaches for heat and mass transfer in liquid desiccant dehumidification system, Appl. Energy, 239, 757, 10.1016/j.apenergy.2019.01.245 Luo, 2014, A review of the mathematical models for predicting the heat and mass transfer process in the liquid desiccant dehumidifier, Renew. Sustain. Energy Rev., 31, 587, 10.1016/j.rser.2013.12.009 Ren, 2020, A review of heat and mass transfer mechanisms of dehumidifiers and regenerators for liquid desiccant cooling systems, Science and Technology for the Built Environment, 26, 465, 10.1080/23744731.2019.1686888 Jain, 2007, Performance analysis of liquid desiccant dehumidification systems, Int. J. Refrig, 30, 861, 10.1016/j.ijrefrig.2006.11.013 Yang, 2015, Experimental study on mass transfer performances of the ultrasonic atomization liquid desiccant dehumidification system, Energy Build., 93, 126, 10.1016/j.enbuild.2015.02.035 Wen, 2018, Enhancing the dehumidification performance of LiCl solution with surfactant PVP-K30, Energy Build., 171, 183, 10.1016/j.enbuild.2018.04.031 Ren, 2019, A review of heat and mass transfer improvement techniques for dehumidifiers and regenerators of liquid desiccant cooling systems, Appl. Therm. Eng., 162, 10.1016/j.applthermaleng.2019.114271 Xiao, 2011, Control performance of a dedicated outdoor air system adopting liquid desiccant dehumidification, Appl. Energy, 88, 143, 10.1016/j.apenergy.2010.06.019 Ge, 2011, Control strategies for a liquid desiccant air-conditioning system, Energy Build., 43, 1499, 10.1016/j.enbuild.2011.02.011 Reddy, 2019, Study on desiccant solution control strategies for efficient liquid desiccant air conditioning system control performance, Sci. Technol. Built Environ., 25, 322, 10.1080/23744731.2018.1526017 Ju, 2019, Step-down relative humidity convective air drying strategy to enhance drying kinetics, efficiency, and quality of American ginseng root (Panax quinquefolium), Drying Technol. Li, 2022, Relative humidity control during shiitake mushroom (Lentinus edodes) hot air drying based on appearance quality, J. Food Eng., 315, 110814, 10.1016/j.jfoodeng.2021.110814 Zhang, 2021, The influence mechanism and control strategy of relative humidity on hot air drying of fruits and vegetables: a review, Drying Technol., 1–18 Jiang, 2020, Dynamic modeling and economic model predictive control of a liquid desiccant air conditioning, Appl. Energy, 259, 10.1016/j.apenergy.2019.114174 Wu, 2016, An model for dynamic humidity control of liquid desiccant dehumidification system, 535 Wu, Q. (2017). Modeling and control of dehumidifier in distributed operating liquid desiccant dehumidification system, Ph.D. Dissertation, Nanyang Technological University, Singapore. https://dr.ntu.edu.sg/. Wu, 2017, Dynamic analysis of an energy efficiency dehumidifier for building applications, 2060 Zhiyu, 2014, Study on air-cooled self-humidifying PEMFC control method based on segmented predict negative feedback control, Electrochim. Acta, 132, 389, 10.1016/j.electacta.2014.04.003 Li, 2015, A novel proportional-derivative (PD) law based fuzzy logic principles assisted controller for simultaneously controlling indoor temperature and humidity using a direct expansion (DX) air conditioning (A/C) system, Internat. J. Refrig., 57, 239, 10.1016/j.ijrefrig.2015.05.011 Zhang, 2020, An online model for predicting dynamic response of a packed liquid desiccant dehumidifier, Energy Build., 224, 10.1016/j.enbuild.2020.110210 Potnis, 1996, Dimensionless mass-transfer correlations for packed-bed liquid-desiccant contactors, Ind. Eng. Chem. Res., 35, 4185, 10.1021/ie960212y Longo, 2005, Experimental and theoretical analysis of heat and mass transfer in a packed column dehumidifier/regenerator with liquid desiccant, Int. J. Heat Mass Transf., 48, 5240, 10.1016/j.ijheatmasstransfer.2005.07.011 Zhang, 2021, Dynamic operational characteristics and preliminary control of a packed liquid desiccant dehumidifier, Energy Build., 248, 10.1016/j.enbuild.2021.111185 Ang, 2005, PID control system analysis, design, and technology, IEEE Trans. Control Syst. Technol., 13, 559, 10.1109/TCST.2005.847331 Daud, 2017, PEM fuel cell system control: A review, Renewable Energy, 113, 620, 10.1016/j.renene.2017.06.027 Lee, 1990, Fuzzy logic in control systems: fuzzy logic controller. I, IEEE Trans. Syst. Man Cybern., 20, 404, 10.1109/21.52551 Zhong, 2017, Simulation based control performance evaluation of a novel fuzzy logic control algorithm for simultaneously controlling indoor air temperature and humidity using a direct expansion (DX) air-conditioning (A/C) system, Proc. Eng., 205, 1792, 10.1016/j.proeng.2017.10.040 Shao, 2022, Investigation on weights setting rule for weights-based fuzzy logic control algorithm utilized in direct expansion air-conditioning systems, Int. J. Refrig, 138, 71, 10.1016/j.ijrefrig.2022.03.005 Wu, 2015, Dynamic analysis of mass transfer in a liquid desiccant dehumidifier, 28