Prediction of smoke back-layering length under different longitudinal ventilations in the subway tunnel with metro train

Tunnelling and Underground Space Technology - Tập 53 - Trang 13-21 - 2016
Shaogang Zhang1, Yongzheng Yao1, Kai Zhu1, Kaiyuan Li1, Ruifang Zhang1, Song Lu1, Xudong Cheng1
1State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, Anhui 230026, PR China

Tài liệu tham khảo

Baum, 1989, Fire induced flow field-theory and experiment, 129 Gannouni, 2015, Numerical study of the effect of blockage on critical velocity and backlayering length in longitudinally ventilated tunnel fires, Tunn. Undergr. Space Technol., 48, 147, 10.1016/j.tust.2015.03.003 Guedri, 2011, Numerical study of radiative heat transfer effects on a complex configuration of rack storage fire, Energy, 36, 2984, 10.1016/j.energy.2011.02.042 Hu, 2008, Studies on buoyancy-driven back-layering flow in tunnel fires, Exp. Therm. Fluid Sci., 32, 1468, 10.1016/j.expthermflusci.2008.03.005 Huo, 2015, A study on ceiling jet characteristics in an inclined tunnel, Tunn. Undergr. Space Technol., 50, 32, 10.1016/j.tust.2015.06.009 Ji, 2012, Experimental investigation on influence of different transverse fire locations on maximum smoke temperature under the tunnel ceiling, Int. J. Heat Mass Tran., 55, 4817, 10.1016/j.ijheatmasstransfer.2012.04.052 Lai, 2014, Experimental research on temperature field and structure performance under different lining water contents in road tunnel fire, Tunn. Undergr. Space Technol., 43, 327, 10.1016/j.tust.2014.05.009 Lee, 2005, An experimental study of the effect of the aspect ratio on the critical velocity in longitudinal ventilation tunnel fires, J. Fire Sci., 23, 119, 10.1177/0734904105044630 Lee, 2012, Effect of vehicular blockage on critical ventilation velocity and tunnel fire behavior in longitudinally ventilated tunnels, Fire Saf. J., 53, 35, 10.1016/j.firesaf.2012.06.013 Lin, 2014, Numerical study on the impact of gradient on semi-transverse smoke control system in tunnel, Tunn. Undergr. Space Technol., 44, 68, 10.1016/j.tust.2014.07.011 Li, 2010, Study of critical velocity and backlayering length in longitudinally ventilated tunnel fires, Fire Saf. J., 45, 361, 10.1016/j.firesaf.2010.07.003 Ma, 2003, Numerical simulation of axi-symmetric fire plumes: accuracy and limitations, Fire Saf. J., 38, 467, 10.1016/S0379-7112(02)00082-6 Meng, 2014, Numerical study on the optimization of smoke ventilation mode at the conjunction area between tunnel track and platform in emergency of a train fire at subway station, Tunn. Undergr. Space Technol., 40, 151, 10.1016/j.tust.2013.09.014 Olenick, 2003, An updated international survey of computer models for fire and smoke, J. Fire Prot. Eng., 13, 87, 10.1177/1042391503013002001 Ris, 1970, Duct fires, Combust. Sci. Technol., 2, 239, 10.1080/00102207008952252 Tang, 2013, Effect of blockage-fire distance on buoyancy driven back-layering length and critical velocity in a tunnel: an experimental investigation and global correlations, Appl. Therm. Eng., 60, 7, 10.1016/j.applthermaleng.2013.06.033 Thomas, 1958, The movement of buoyant fluid against a stream and the venting of underground fires, Fire Res. Note, 351 Wang, 2015, Maximum temperature of smoke beneath ceiling in tunnel fire with vertical shafts, Tunn. Undergr. Space Technol., 50, 189, 10.1016/j.tust.2015.06.011 Weng, 2015, Prediction of backlayering length and critical velocity in metro tunnel fires, Tunn. Undergr. Space Technol., 47, 64, 10.1016/j.tust.2014.12.010 Weng, 2014, Full-scale experiment and CFD simulation on smoke movement and smoke control in a metro tunnel with one opening portal, Tunn. Undergr. Space Technol., 42, 96, 10.1016/j.tust.2014.02.007 Wu, 2000, Control of smoke flow in tunnel fires using longitudinal ventilation systems – a study of the critical velocity, Fire Saf. J., 35, 363, 10.1016/S0379-7112(00)00031-X Yang, 2011, Experimental study and numerical simulation for a storehouse fire accident, Build. Environ., 46, 1445, 10.1016/j.buildenv.2011.01.012 Yi, 2014, An experimental study on critical velocity in sloping tunnel with longitudinal ventilation under fire, Tunn. Undergr. Space Technol., 43, 198, 10.1016/j.tust.2014.05.017 Zhang, 2015, Numerical simulation of wood crib fire behavior in a confined space using cone calorimeter data, J. Therm. Anal. Calorim., 119, 2291, 10.1007/s10973-014-4291-4 Zhou, 2014, Study on fire characteristics of subway train running with fire, 3785