Physiological preparation for studying the response of subcutaneously implanted glucose and oxygen sensors

Journal of Biomedical Engineering - Tập 11 - Trang 362-368 - 1989
S. Ertefai1, D.A. Gough1
1Department of Applied Mechanics and Engineering Sciences, Bioengineering Group, University of California at San Diego, La Jolla, California 92093, USA

Tài liệu tham khảo

Cahill, 1976, “Control” and Diabetes, New England J of Med, 294, 1004, 10.1056/NEJM197604292941811 Shichiri, 1986, Telemetry glucose monitoring device with needle-type glucose sensor: a useful tool for blood glucose monitoring in diabetic individuals, Diabetes Care, 9, 298, 10.2337/diacare.9.3.298 Muller, 1986, Kontinuierliche messung der glukosekonzentration im subkutanen gewebe mit implantierbaren enzymelektroden, Biomed Biochim Acta, 45, 769 Gough, 1986, Short-term in vivo operation of a glucose sensor, Trans Amer Soc Artif Intern Organs, 32, 148 Claremont, 1986, Subcutaneous implantation of a ferrocene-mediated glucose sensor in pigs, Diabetologia, 29, 817, 10.1007/BF00873223 Lerner, 1982, Measurement of glucose concentration in the presence of coreactants with a platinum electrode, Diabetes Care, 5, 229, 10.2337/diacare.5.3.229 Schultz, 1982, Affinity sensor: a new technique for developing implantable sensors for glucose and other metabolites, Diabetes Care, 5, 245, 10.2337/diacare.5.3.245 Kondo, 1982, A miniature glucose sensor, implantable in the blood stream, Diabetes Care, 5, 218, 10.2337/diacare.5.3.218 Armour JC, Lucisano JY, McKean BD, Gough DA. Application of a Chronic Intravascular Blood Glucose Sensor in Dogs. In review. Gough, 1988, Issues related to in vitro operation of potentially implantable enzyme electrode glucose sensors, Hormone and Metabolic Res, 30 Lucisano, 1987, In vitro stability of an oxygen sensor, Analyt Chem, 59, 736, 10.1021/ac00132a012 Gough, 1985, Two-dimensional enzyme electrode sensor for glucose, Analyt Chem, 57, 2351, 10.1021/ac00289a042 Lucisano, 1988, Transient response of the two-dimensional glucose sensor, Analyt Chem, 60, 1272, 10.1021/ac00164a007 McKean, 1988, A telemetry-instrumentation system for chronically implanted glucose and oxygen sensors, IEEE Trans on Biomed Eng, 35, 526, 10.1109/10.4581 Papenfuss, 1979, A transparent access chamber for the rat dorsal skin fold, Microvascular Res, 18, 311, 10.1016/0026-2862(79)90039-6 Barroso-Aranda, 1988, Granulocytes and no-reflow phenomena in irreversible haemorrhagic shock, Cir Res, 63, 437, 10.1161/01.RES.63.2.437 Luft, 1961, Improvements in epoxy resin embedding methods, J of Biophys and Biochem Cytology, 9, 409, 10.1083/jcb.9.2.409 Underwood, 1970, Quantitative Stereology, 43 Woodward, 1982, How fibroblasts and giant cells encapsulate implants: considerations in design of glucose sensors, Diabetes Care, 5, 278, 10.2337/diacare.5.3.278 Hunt, 1964, A new method of determining tissue oxygen tension, Lancet, 2, 1370, 10.1016/S0140-6736(64)91161-4 Niinikoski, 1972, Measurement of wound oxygen with implanted Silastic tube, Surgery, 71, 22 Wolfson, 1982, Glucose concentration at possible sensor tissue implant sites, Diabetes Care, 5, 162, 10.2337/diacare.5.3.162 Niinikoski, 1971, Oxygen and carbon dioxide tensions in experimental wounds, Surg Gynecol and Obstet, 133, 1003 Silver, 1968, The measurement of oxygen tension in healing tissue, Prog in Resp Res, 3, 124, 10.1159/000386224