Analysis of annual heating and cooling energy requirements for office buildings in different climates in Turkey

Energy and Buildings - Tập 40 - Trang 763-773 - 2008
Nurdil Eskin1, Hamdi Türkmen1
1Istanbul Technical University, Mechanical Engineering Faculty, Istanbul, Turkey

Tài liệu tham khảo

World Energy Council, Turkish National Committee (WECTNC) Energy Report, 2002. Clarke, 2001 EnergyPlus Computer Program and Engineering Document, The US Department of Energy, http://www.eere.energy.gov, 2003. Chirarattananon, 2004, An ottv-based energy estimation model for commercial buildings in Thailand, Energy and Buildings, 36, 680, 10.1016/j.enbuild.2004.01.035 Leung, 2005, Willingness to pay for improved environmental performance of the building envelope of office buildings in Hong Kong, Indoor and Built Environment, 14, 147, 10.1177/1420326X05052562 Yik, 2005, An evaluation of the appropriateness of using overall thermal transfer value (OTTV) to regulate envelope energy performance of air-conditioned buildings, Energy, 30, 41, 10.1016/j.energy.2004.03.001 Li, 2003, Climatic effects on cooling load determination in subtropical regions, Energy Conversion and Management, 44, 1831, 10.1016/S0196-8904(02)00189-9 Li, 2002, Day lighting and its implications to overall thermal transfer value (OTTV) determinations, Energy, 27, 991, 10.1016/S0360-5442(02)00067-1 Lam, 2000, Energy analysis of commercial buildings in subtropical climates, Building and Environment, 35, 19, 10.1016/S0360-1323(98)00067-5 Lam, 1994, A survey of building envelope designs for commercial buildings in Hong-Kong, Building Research and Information, 22, 79, 10.1080/09613219408727355 Tham, 1993, Conserving energy without sacrificing thermal comfort, Building and Environment, 28, 287, 10.1016/0360-1323(93)90034-Z Ardehali, 1997, Evaluation of HVAC system operational strategies for commercial buildings, Energy Conversion and Management, 38, 225, 10.1016/S0196-8904(96)00039-8 Alhomoud, 1997, Optimum thermal design of office buildings, International Journal of Energy Research, 21, 941, 10.1002/(SICI)1099-114X(199708)21:10<941::AID-ER302>3.0.CO;2-Y Bauer, 1998, A simplified correlation method accounting for heating and cooling loads in energy-efficient buildings, Energy and Buildings, 27, 147, 10.1016/S0378-7788(97)00035-2 Laine, 1994, Realization of good indoor climate in low-energy office, Building and Environment, 29, 401, 10.1016/0360-1323(94)90041-8 Vine, 1998, Office worker response to an automated Venetian blind and electric lighting system: a pilot study, Energy and Buildings, 28, 205, 10.1016/S0378-7788(98)00023-1 Becker, 2002, Inter-related effects of cooling strategies and building features on energy performance of office buildings, Energy and Buildings, 34, 25, 10.1016/S0378-7788(01)00081-0 Dascalaki, 2002, On the potential of retrofitting scenarios for offices, Building and Environment, 37, 557, 10.1016/S0360-1323(02)00002-1 Gratia, 2003, Design of low energy buildings, Energy and Buildings, 35, 473, 10.1016/S0378-7788(02)00160-3 Franzetti, 2004, Influence of the coupling between daylight and artificial lighting on thermal loads in office buildings, Energy and Buildings, 36, 117, 10.1016/j.enbuild.2003.10.005 Unver, 2003, Effect of the facade alternatives on the daylight luminance in offices, Energy and Buildings, 35, 737, 10.1016/S0378-7788(02)00227-X Unver, 2004, Prediction of building envelope performance in the design stage: an application for office buildings, Building and Environment, 39, 143, 10.1016/j.buildenv.2003.08.014 Crawley, 2001, EnergyPlus: creating a new-generation building energy simulation program, Energy and Buildings, 33, 319, 10.1016/S0378-7788(00)00114-6 Strand, 1999, Enhancing and extending the capabilities of the building heat balance simulation technique for use in EnergyPlus, 217 F. Gurdil, M. Turan, Determination of climatic regions for buildings: an attempt for Turkey, TUBITAK (Scientific and Technical Research Council of Turkey) Building Research Institute, Research Report No. A70, Ankara, 1990. Crow, 1981, Development of hourly data for weather year for energy calculations (WYEC), including solar data, at 21 stations throughout the US, ASHRAE Transactions, 87, 896 Colliver, 1981, Effect of data period—of record on estimation of HVAC&R design temperatures, ASHRAE Transactions, 106, 466 Turkish National Meteorological Institution (DME), http://www.meteor.gov.tr, 2004. Turkish weather data, Technical Publication of Turkish Society of HVAC & Sanitary Engineers (TTMD), 2000. The Ministry of Public Works and Settlements, Turkish Specifications in Earthquake Regions (in Turkish and English), http://www.bayindirlik.gov.tr, 2001. Katimapula, 1991, A methodology to identify diurnal load shapes for non-weather dependent electric end-users, 17 TS 825 Thermal insulation in buildings, Turkish Standards No. 825, Turkish Standards Institution (TSE) (in Turkish, English, French, German), http://www.tse.gov.tr, 2003. TS EN 823 Thermal insulation products for in building applications-determination of thickness, Turkish Standards No. 823, Turkish Standards Institution (TSE) (in Turkish, English, French, German), http://www.tse.gov.tr, 2003. Tavil, 2005, Thermal behavior of masonry walls in Istanbul, Constructions and Building Materials, 18, 111, 10.1016/j.conbuildmat.2003.08.014 Inanici, 2000, Thermal performance optimization of building aspect ratio and south window size in five cities having different climatic characteristics of Turkey, Building and Environment, 35, 41, 10.1016/S0360-1323(99)00002-5 Givoni, 1994