The stability of the sacroiliac joint was studied using an in vitro loading system. Forty-nine sacroiliac joints taken from fresh cadavers were examined. The ligamentous structures of the joint disrupted at 3368 ± 923 N under transverse loading. Higher disruption forces were observed under ventrocranial (4933 ± 1038 N) and dorsocranial (5150 ±947 N) loading. At joint failure the displacement in loading direction ranged from 5.5 ± 2.3 mm in the transverse to 6.6 ± 2.3 mm in the dorsocranial direction. In some experiments the interlocking effect between the articular surfaces of the sacrum and ilium were examined. The best interlocking capacity was observed under dorsocranial loading. This capacity is much higher than the friction in other human joints. The study shows that correct anatomical reconstruction without displacement increases the stability of the disrupted sacroiliac joint.

Tài liệu tham khảo

Albrecht F, Brug E (1982) Indikation und Verfahrenswahl bei der Osteosynthese dislozierter Beckenringsverletzungen. Unfallheilkunde 85:431–440 Berner W, Oestern HJ, Sorge J (1982) Ligamentäre Beckenringsverletzungen — Behandlung und Spätergeb-nisse. Unfallheilkunde 85:377–387 Bonnel F (1975) Biomechanische Betrachtungen über Beckenverletzungen und die Anwendung des Fixateur externe bei Zerreißungen der Symphyse und des Sakro-Iliakalgelenkes. Hefte Unfallheilkd 124:161–163 Brown TD, Patterson-Stone J, Schuster JH, Mears DC (1982) External fixation of unstable pelvic ring fractures: comparative rigidity of some current frame configurations. Med Biol Eng Comput 20:727–733 Carabalona P, Rabichong P, Bonnel F, Perruchon E, Peguret F (1973) Apports du fixateur externe dans les disjonctions du pubis et de l'articulation sacro-iliaque. Montpell Chir 19:61–70 Fessler J (1894) Festigkeit der menschlichen Gelenke mit besonderer Berücksichtigung des Bandapparates. Habilitationsschrift, Ludwig Maximillian University, Munich Gunterberg B, Romanus B, Stener B (1976) Pelvic strength after major amputation of the sacrum. Acta Orthop Scand 47:635–642 Miller JAA, Schultz AB, Anderson GB (1987) Load-displacement behavior of sacroiliac joints. J Orthop Res 5:92–101 Rubash HE, Brown TD, Nelson DD, Mears DC (1983) Comparative mechanical performances of some new devices for fixation of unstable pelvic ring fractures. Med Biol Eng Comput 21:657–663 Slätis P, Karaharju EO (1975) External fixation of the pelvic girdle with a trapezoid compression frame. Injury 7:53–56 Tile M, Pennal G (1980) Pelvic disruption: principles of management. Clin Orthop 151:56–64 Walter PS (1974) The friction of internal artificial joints. In: Human locomotor engineering. Institution of Mechanical Engineers, London, pp 76–79 Weisl H (1954) The ligaments of the sacro-iliac joint examined with particular reference to their function. Acta Anat 20:201–213