Tóm tắt

AbstractPurpose:

To determine the apparent diffusion coefficient (ADC) values of lipid and hemorrhage in atherosclerotic plaque in human carotid arteries in vivo and compare the values obtained from ex vivo carotid endarterectomy specimens.

Materials and Methods:

In vivo diffusion‐weighted imaging (DWI) of carotid plaques was performed using a 2D single shot Interleaved Multislice Inner Volume Diffusion Weighted Echo Planar Imaging (2D ss‐IMIV DWEPI) on 8 subjects who subsequently underwent carotid endarterectomy. A total of 32 slices used to construct the ADC maps were reviewed for the measurement of the mean ADC values in vessel wall, hemorrhage, and lipid necrotic core. The 8 endarterectomy specimens were scanned using by three‐dimensional ms‐IV‐DWEPI. After the ADC maps were created, the mean ADC values in the same locations selected for in vivo values were calculated.

Results:

The mean ADC values obtained from in vivo DWI in normal vessel wall, lipid rich core, and hemorrhage were 1.27 ± 0.16, 0.38 ± 0.1, and 0.98 ± 0.25 × 10−3 mm2/s, respectively. The mean ADC values in ex vivo lipid necrotic core, and hemorrhage were 0.33 ± 0.08, 1.28 ± 0.10 × 10−3 mm2/s, respectively. These components mean ADC values obtained from in vivo and ex vivo ADC maps were compared.

Conclusion:

ADC values of the carotid plaque components in vivo are consistent with values obtained from ex vivo endarterectomy specimens. The ability to obtain consistent plaque ADC values in vivo indicates that this technique could be an integral part of the basis for plaque component identification in conjunction with other MRI techniques. J. Magn. Reson. Imaging 2011;. © 2011 Wiley Periodicals, Inc.

Từ khóa


Tài liệu tham khảo

10.1161/01.CIR.0000146787.16297.E8

10.1001/jama.292.15.1845

10.1161/01.STR.30.7.1440

10.1161/CIRCULATIONAHA.104.528174

10.1161/01.CIR.98.15.1541

10.1097/00002142-200106000-00006

10.1161/01.STR.0000125856.25309.86

10.1161/01.CIR.0000028591.44554.F9

10.1007/BF00593376

10.1161/ATVB.15v10.1533

Bammer R, 2003, Line scan diffusion imaging of the spine, AJNR Am J Neuroradiol, 24, 5

10.1161/01.ATV.17.3.542

10.1161/01.ATV.0000149673.00564.0a

10.1016/0003-9861(83)90228-X

10.1161/01.ATV.19.11.2756

10.1148/radiol.2482071114

10.1002/jmri.21360

10.1001/archsurg.1982.01380350069010

10.1002/mrm.10618

10.1002/jmri.21944

10.1002/mrm.20711

10.1016/j.mri.2005.04.009

10.1002/mrm.20296

10.1002/mrm.10152

10.1007/s00234-010-0680-y

10.1161/ATVBAHA.107.141028

10.1161/CIRCULATIONAHA.104.504167

10.1161/01.ATV.0000155965.54679.79